|
1. |
A randomized trial of transcutaneous extraction atherectomy in femoral arteries: Intravascular ultrasound observations |
|
Journal of Clinical Ultrasound,
Volume 23,
Issue 8,
1995,
Page 461-471
Shigeru Nakamura,
Robert M. Conroy,
Ian L. Gordon,
Larry‐Stuart Deutsch,
Bavani Maheswaran,
Curtis S. Antone,
Jonathan M. Tobis,
Preview
|
PDF (1215KB)
|
|
摘要:
AbstractObjectives. The purpose of this study was to test the hypothesis that in occlusions of the superficial femoral artery, removal of atherosclerotic plaque would result in a higher long‐term patency rate compared to balloon dilatation alone. A secondary hypothesis was that long term patency would be proportional to the amount of plaque removed.Methods. A randomized controlled study of patients with occluded superficial femoral arteries was performed comparing balloon dilatation alone versus a 2.7 mm or a larger (4.0 mm or 4.7 mm) transcutaneous extraction catheter (TEC) atherectomy device followed by balloon dilatation. The effect of these devices on plaque area was assessed directly by intravascular ultrasound imaging.Results. The mean occlusion length was 19.4 cm ± 11.7 cm. The mean lumen area increased from 4.7 mm2to 15.1 mm2, primarily due to balloon dilatation, but the mean atheroma area of 19.8 mm2did not change with either size of TEC device. Although the initial procedure success rate was high (79%), the 6 month patency was only 45%. There was no difference in 6 month patency between the 3 groups.Conclusions. The data indicate that the TEC atherectomy devices do not remove a significant amount of atherosclerotic plaque in occluded superficial femoral arteries. The 6 month patency is no different with these atherectomy devices than with balloon dilatation alone. The larger (4.0 mm or 4.7 mm) TEC device does not remove any more tissue than the smaller (2.7 mm) device. The use of intravascular ultrasound to quantitate the effects of this atherectomy device provides important insights into the mechanism of action and lack of efficacy of the TEC atherectomy catheter. © 1995 John Wiley&Sons,
ISSN:0091-2751
DOI:10.1002/jcu.1870230802
出版商:Wiley Subscription Services, Inc., A Wiley Company
年代:1995
数据来源: WILEY
|
2. |
Degenerated uterine leiomyoma mimicking acute appendicitis: Sonographic diagnosis |
|
Journal of Clinical Ultrasound,
Volume 23,
Issue 8,
1995,
Page 473-475
Marshall E. Yacoe,
R. Brooke Jeffrey,
Preview
|
PDF (380KB)
|
|
摘要:
AbstractThe present study reviews four cases in which degenerated uterine leiomyomas mimicked appendicitis clinically. The correct diagnosis was made prospectively by sonography in each case. Appendicitis was excluded by graded compression sonography and an exophytic uterine leiomyoma was identified at the point of maximal symptoms. The leiomyomas demonstrated central hypoechoic foci, but no detectable Doppler flow indicating necrosis. Although the phenomenon of a degenerated uterine leiomyoma mimicking appendicitis clinically is known, sonographic diagnosis has not been reported previously. The importance of making this diagnosis sonographically is that management of a degenerated leiomyoma is conservative and unnecessary surgery could be avoided. © 1995 John Wiley&Sons, Inc
ISSN:0091-2751
DOI:10.1002/jcu.1870230803
出版商:Wiley Subscription Services, Inc., A Wiley Company
年代:1995
数据来源: WILEY
|
3. |
Hepatic venous Doppler waveforms: Changes in pregnancy |
|
Journal of Clinical Ultrasound,
Volume 23,
Issue 8,
1995,
Page 477-482
C. A. Roobottom,
J. D. Hunter,
M. J. Weston,
P. A. Dubbins,
Preview
|
PDF (678KB)
|
|
摘要:
AbstractA total of 75 fasted healthy normal volunteers were examined during various stages of pregnancy. Examinations were performed in a supine position using an Acuson 128 ultrasound scanner with a 3.5 MHz transducer. Doppler interrogation of the middle hepatic vein was made during quiet respiration by one of three examiners. The Doppler waveforms were subsequently assessed blindly by one of the authors and categorized as normal, damped, or flat. Between 12 and 20 weeks, the majority of patients had normal hepatic pulsatility (64%) with 20% damped and 16% flat. Between 20 and 30 weeks there was a significant change (p>0.001) with 68% being flat, 20% damped, and only 12% normal. In the last 10 weeks of pregnancy the changes were more marked: 80% were flat, 12% dampened, and 8% normal. There was a profound change in hepatic venous pulsatility during pregnancy. Hepatic waveforms changed from their normal pulsatile nature to become completely flat with increasing gestation. These changes were more frequent and more marked the further gestation progressed. © 1995 John Wiley&Sons, Inc
ISSN:0091-2751
DOI:10.1002/jcu.1870230804
出版商:Wiley Subscription Services, Inc., A Wiley Company
年代:1995
数据来源: WILEY
|
4. |
Review of artifacts associated with transrectal ultrasound: Understanding, recognition, and prevention of misinterpretation |
|
Journal of Clinical Ultrasound,
Volume 23,
Issue 8,
1995,
Page 483-494
Frans‐jan J. H. Hulsmans,
Jonas A. Castelijns,
Jacques W. A. J. Reeders,
Guido N. J. Tytgat,
Preview
|
PDF (1691KB)
|
|
摘要:
AbstractArtifacts are inadequate representations of the structures being imaged. Transrectal ultrasound (TRUS) used for evaluating rectal tumors has its own, unique spectrum of artifacts such as (1) pseudomasses (beam thickness: imaging of rectal folds; mirror image: reflection at an intraluminal fluid level); (2) inadequate size of the lesion (mirror image or grating lobes); (3) simulation of malignant infiltration (beam thickness, attenuation or refraction); (4) incomplete field of view (shadowing; reverberation or mirror‐image); (5) confusing echo patterns (side lobe artifacts or mirror image: reflection at the balloon surface). The understanding of the physical properties of ultrasound is the basis for the recognition of these artifacts and prevention of misinterpretation. We present a review of these artifacts and their causes. © 1995 John Wiley&Sons, I
ISSN:0091-2751
DOI:10.1002/jcu.1870230805
出版商:Wiley Subscription Services, Inc., A Wiley Company
年代:1995
数据来源: WILEY
|
5. |
Tuberculous myositis: CT and sonographic findings in two cases |
|
Journal of Clinical Ultrasound,
Volume 23,
Issue 8,
1995,
Page 495-499
Andrew C. Wilbur,
Alexander A. Gorodetsky,
John F. Hibbeln,
Robert I. Aizenstein,
Preview
|
PDF (576KB)
|
|
ISSN:0091-2751
DOI:10.1002/jcu.1870230806
出版商:Wiley Subscription Services, Inc., A Wiley Company
年代:1995
数据来源: WILEY
|
6. |
Biliary ascariasis: Ultrasound diagnosis |
|
Journal of Clinical Ultrasound,
Volume 23,
Issue 8,
1995,
Page 500-501
Pankaj Mehta,
A. K. Sharma,
Sanjay Saluja,
N. K. Prabhu,
Preview
|
PDF (190KB)
|
|
ISSN:0091-2751
DOI:10.1002/jcu.1870230807
出版商:Wiley Subscription Services, Inc., A Wiley Company
年代:1995
数据来源: WILEY
|
7. |
Cor triatriatum dexter diagnosed by transesophageal echocardiography |
|
Journal of Clinical Ultrasound,
Volume 23,
Issue 8,
1995,
Page 502-504
Rosario Fiorilli,
Giancarlo Argento,
Biagio Tomasco,
Walter Serino,
Preview
|
PDF (366KB)
|
|
ISSN:0091-2751
DOI:10.1002/jcu.1870230808
出版商:Wiley Subscription Services, Inc., A Wiley Company
年代:1995
数据来源: WILEY
|
8. |
The engorged fallopian tube: A new sonographic sign for adnexal torsion |
|
Journal of Clinical Ultrasound,
Volume 23,
Issue 8,
1995,
Page 505-507
Benjamin Caspi,
Peleg Ben‐Galim,
Ariel Weissman,
Zvi Appleman,
Preview
|
PDF (327KB)
|
|
ISSN:0091-2751
DOI:10.1002/jcu.1870230809
出版商:Wiley Subscription Services, Inc., A Wiley Company
年代:1995
数据来源: WILEY
|
9. |
New product information |
|
Journal of Clinical Ultrasound,
Volume 23,
Issue 8,
1995,
Page 508-508
Preview
|
PDF (153KB)
|
|
ISSN:0091-2751
DOI:10.1002/jcu.1870230810
出版商:Wiley Subscription Services, Inc., A Wiley Company
年代:1995
数据来源: WILEY
|
10. |
Calendar |
|
Journal of Clinical Ultrasound,
Volume 23,
Issue 8,
1995,
Page 509-509
Preview
|
PDF (159KB)
|
|
ISSN:0091-2751
DOI:10.1002/jcu.1870230811
出版商:Wiley Subscription Services, Inc., A Wiley Company
年代:1995
数据来源: WILEY
|
|