|
1. |
Letters to the Editor |
|
Journal of Clinical Ultrasound,
Volume 12,
Issue 3,
1984,
Page 9-10
R. J. Carpenter,
James P. Youngblood,
Robert T. Stein,
J. E. E. Fleming,
M. B. McNay,
Preview
|
PDF (149KB)
|
|
ISSN:0091-2751
DOI:10.1002/jcu.1870120302
出版商:Wiley Subscription Services, Inc., A Wiley Company
年代:1984
数据来源: WILEY
|
2. |
Calendar |
|
Journal of Clinical Ultrasound,
Volume 12,
Issue 3,
1984,
Page 16-17
Preview
|
PDF (251KB)
|
|
ISSN:0091-2751
DOI:10.1002/jcu.1870120319
出版商:Wiley Subscription Services, Inc., A Wiley Company
年代:1984
数据来源: WILEY
|
3. |
Tongue Movement During Speech: A Real‐Time Ultrasound Evaluation |
|
Journal of Clinical Ultrasound,
Volume 12,
Issue 3,
1984,
Page 125-133
Thomas H. Shawker,
Barbara C. Sonies Phd,
Preview
|
PDF (1004KB)
|
|
摘要:
AbstractTongue movement during production of the speech sounds /a/, /i/, and /k/ was examined with a real‐time sector scanner positioned submentally. With this technique, it is possible to obtain excellent visualization of the tongue surface and to identify much of the intrinsic soft tissue anatomy of the tongue and floor of the mouth. Tongue movement and configuration were found to be consistent for 10 normal speakers, especially for /i/and /k/. Three patients with neurological disease and dysarthria showed varying but significant differences in articulation compared to normals. It appears that real‐time ultrasound imaging of the oral cavity is a potentially valuable technique for the clinical investigation of normal and abnormal spe
ISSN:0091-2751
DOI:10.1002/jcu.1870120303
出版商:Wiley Subscription Services, Inc., A Wiley Company
年代:1984
数据来源: WILEY
|
4. |
Usefulness of Renal Ultrasonography for Assessment of Severity and Course of Acute Tubular Necrosis |
|
Journal of Clinical Ultrasound,
Volume 12,
Issue 3,
1984,
Page 135-139
Gakuji Nomura,
Eiichi Kinoshita,
Yuji Yamagata,
Nobuhiko Koga,
Preview
|
PDF (492KB)
|
|
摘要:
AbstractRenal ultrasonographic studies were done in 26 patients with acute tubular necrosis. Prominent findings were an increase in renal size, especially the anteroposterior diameter, and sharp delineation of swollen pyramids. The ratio of anteroposterior to longitudinal diameter (WL) was correlated with serum creatinine levels and inversely correlated with urine osmolalities. It was well correlated with the recovery time of acute renal failure. The patient group having an increased H/L had a mean recovery time of 32.4 days and 11 of the 12 patients required hemodialysis (mean of 10 times). The patient group having a normal H/L had a mean recovery time of 15.5 days and 9 of the 14 required hemodialysis (mean of 3 times).
ISSN:0091-2751
DOI:10.1002/jcu.1870120304
出版商:Wiley Subscription Services, Inc., A Wiley Company
年代:1984
数据来源: WILEY
|
5. |
Sonographic Patterns of the Gallbladder in Acute Viral Hepatitis |
|
Journal of Clinical Ultrasound,
Volume 12,
Issue 3,
1984,
Page 141-146
Giulia Maresca,
Anna Maria De Gaetano,
Paola Mirk,
Corrado Colagrande,
Roberto Cauda,
Giovanni Federico,
Preview
|
PDF (525KB)
|
|
摘要:
AbstractUltrasound was used for a serial evaluation of gallbladder modifications in 61 patients with acute viral hepatitis during both the acute phase of the illness and recovery. Most of the patients studied within 7 days from the onset of symptoms and/or jaundice showed sonographic abnormalities of the gallbladder (increased wall thickness, reduced volume, abnormal bile content). A normal ultrasound pattern of the gallbladder was progressively restored during the clinical recovery in most of the patients. A statistical correlation was found between the gallbladder wall thickness and the alanine transferase index.
ISSN:0091-2751
DOI:10.1002/jcu.1870120305
出版商:Wiley Subscription Services, Inc., A Wiley Company
年代:1984
数据来源: WILEY
|
6. |
Ultrasonic Characterization of Blood During Coagulation |
|
Journal of Clinical Ultrasound,
Volume 12,
Issue 3,
1984,
Page 147-153
K. Kirk Shung,
Dingyu Fei Msee,
Ying‐Wei Yuan Bsbe,
William C. Reeves,
Preview
|
PDF (550KB)
|
|
摘要:
AbstractRecently ultrasound has been found to be extremely useful in detecting intracardiac thrombi as well as intracranial hemorrhages in neonates. The principal criterion used for clinical diagnosis of thrombus has been an increase in the echogenicity of clotted blood. However, echogenicity is a rather nonspecific and qualitative description of tissue ultrasonic properties. A rise in echogenicity could be the result of an increase in ultrasonic backscatter, or a decrease in attenuation, or a combination of both. In order to ascertain the mechanism responsible for the clinically observed increase in echogenicity and thus put the technique on a firm foundation, we have measured serially the ultrasonic velocity, attenuation and backscatter in human blood up to 24 hours following the onset of coagulation. Preliminary results show that all three ultrasonic properties increase during this time period. At 24 hours following clotting, the mean rises in velocity, attenuation and backscatter are 3.36 ± 0.35 ± 103cm/sec, 2.3 ± 0.22 db/cm and 18.5 ± 1.2dB per unit volume of blood (at 7.5 MHz and a temperature of 23°C), respectively. These results indicate that the increase in echogenicity of a thrombus is due to a substantial increase in ultrasonic backscatter, which is moderated to a certain extent by the accompanied increase in attenua
ISSN:0091-2751
DOI:10.1002/jcu.1870120306
出版商:Wiley Subscription Services, Inc., A Wiley Company
年代:1984
数据来源: WILEY
|
7. |
Efficacy of CW‐Doppler and Duplex System Examinations for the Evaluation of Extracranial Carotid Disease |
|
Journal of Clinical Ultrasound,
Volume 12,
Issue 3,
1984,
Page 155-161
Michael Hennerici,
Hans‐Joachim Freund,
Preview
|
PDF (791KB)
|
|
摘要:
AbstractThe efficacy of different ultrasound methods for the detection of extracranial arterial disease (E AD) was evaluated on the basis of the comparison with angiography. High‐resolution B‐scan imaging combined with a multigated pulsed Doppler flow pattern analysis (Duplex system) achieved the best results for the detection of morphological and hemodynamic changes ofnonstenotic lesions and low grade stenosis.However, a technically unsatisfactory examination rate of 19%, the failure to differentiate between total and subtotal carotid occlusions, underestimation of significant stenosis and impracticable vertebral flow studies were disadvantages of the Duplex technique. CW‐Doppler examinations proved to be more precise and more reliable for the detection ofsignificant stenosis and occlusions.Since vertebral blood flow studies were impractical with the Duplex system, CW‐Doppler provides more comprehensive information about the hemodynamics of cerebral blood
ISSN:0091-2751
DOI:10.1002/jcu.1870120307
出版商:Wiley Subscription Services, Inc., A Wiley Company
年代:1984
数据来源: WILEY
|
8. |
Sonographic Appearance of Accessory Spleen |
|
Journal of Clinical Ultrasound,
Volume 12,
Issue 3,
1984,
Page 163-165
Judith F. Katz,
Robert A. Kane,
Preview
|
PDF (256KB)
|
|
ISSN:0091-2751
DOI:10.1002/jcu.1870120308
出版商:Wiley Subscription Services, Inc., A Wiley Company
年代:1984
数据来源: WILEY
|
9. |
Sonographic Diagnosis of Neonatal Diaphragmatic Inversion |
|
Journal of Clinical Ultrasound,
Volume 12,
Issue 3,
1984,
Page 166-167
Dorit D. Adlermd,
Barry I. Samuels,
Caroline E. Blane,
Preview
|
PDF (172KB)
|
|
ISSN:0091-2751
DOI:10.1002/jcu.1870120309
出版商:Wiley Subscription Services, Inc., A Wiley Company
年代:1984
数据来源: WILEY
|
10. |
Ultrasonic Diagnosis of Primary Sarcoma of the Gallbladder |
|
Journal of Clinical Ultrasound,
Volume 12,
Issue 3,
1984,
Page 168-170
Julio C. U. Coelho,
Alfredo Wallbach,
Gilda Kasting,
Ricardo R. Moreira,
Preview
|
PDF (406KB)
|
|
ISSN:0091-2751
DOI:10.1002/jcu.1870120310
出版商:Wiley Subscription Services, Inc., A Wiley Company
年代:1984
数据来源: WILEY
|
|