1. |
Facilities Management |
|
Architectural Science Review,
Volume 35,
Issue 3,
1992,
Page 81-82
Fergus Fricke,
Preview
|
PDF (197KB)
|
|
ISSN:0003-8628
DOI:10.1080/00038628.1992.9696718
出版商:Taylor & Francis Group
年代:1992
数据来源: Taylor
|
2. |
Studies on the Effect of Mean Wind Speed Profile on Rate of Air Flow Through Cross-Ventilated Enclosures |
|
Architectural Science Review,
Volume 35,
Issue 3,
1992,
Page 83-88
Ishwar Chand,
P.K. Bhargava,
V.K. Sharma,
N.L.V. Krishak,
Preview
|
PDF (839KB)
|
|
摘要:
The paper discusses wind tunnel studies on the effect of the mean speed profile of the on-blowing wind on the rate of air flow through cross ventilated enclosures. The mean wind speed profiles represented by a simple power law, with exponents ranging between 0.12 and 0.4, were generated in the test section of the tunnel. A model of a room was exposed to various wind profiles, and corresponding rates of air flow were measured. It was observed that average wind speed through the window decreases with an increase in the power-law exponent. An empirical relationship was also derived between the power-law exponent, the average wind speed through the inlet and the average outdoor wind speed at the window level.
ISSN:0003-8628
DOI:10.1080/00038628.1992.9696719
出版商:Taylor & Francis Group
年代:1992
数据来源: Taylor
|
3. |
Low Cost Alternatives to Mineral Fibres for Acoustic Insulation in Plasterboard Walls |
|
Architectural Science Review,
Volume 35,
Issue 3,
1992,
Page 89-96
P.P. Narang,
Preview
|
PDF (695KB)
|
|
摘要:
The acoustic performance of stud-framed lightweight partition walls is strongly affected by the presence or absence of sound-absorbing materials in the cavity. Fibreglass, a commonly used cavity absorbent, has come under criticism over potential adverse health effects owing to its fibrous nature. This paper investigates some low cost alternatives that might be used for providing cavity absorption in such walls and yet offer sound insulation similar to that achieved by using fibreglass. A minimum improvement in the STC rating of 4 points was observed by using different cavity absorbents, with some options offering STC ratings similar to those achieved with conventional fibreglass. The effect of adding an extra layer of plasterboard with a corresponding equivalent reduction in the stud width was also studied.
ISSN:0003-8628
DOI:10.1080/00038628.1992.9696720
出版商:Taylor & Francis Group
年代:1992
数据来源: Taylor
|
4. |
The Modern Movement, Structural Honesty, and Environmental Verity |
|
Architectural Science Review,
Volume 35,
Issue 3,
1992,
Page 97-100
HenryJ. Cowan,
Preview
|
PDF (945KB)
|
|
摘要:
‘Modern Architecture’ has been burdened, at least by its more earnest disciples, with unnecessary and unhelpful moral principles, particularly honesty in the use of structures and materials. Many of its problems could have been overcome by ‘faking’, which was common in Roman and Renaissance architecture.
ISSN:0003-8628
DOI:10.1080/00038628.1992.9696721
出版商:Taylor & Francis Group
年代:1992
数据来源: Taylor
|
5. |
A Study of the Influence of Furniture on the Thermal Behaviour of Interior Thermal Mass |
|
Architectural Science Review,
Volume 35,
Issue 3,
1992,
Page 101-105
F.X. N. Soelami,
J.A. Ballinger,
Preview
|
PDF (379KB)
|
|
摘要:
Present day thermal behaviour models assume direct solar energy entering a room through windows to be evenly distributed over room surfaces, but in reality the distribution depends on window positions and interior furniture. This paper describes a study of the shading effects of furniture on the thermal behaviour of interior thermal mass.
ISSN:0003-8628
DOI:10.1080/00038628.1992.9696722
出版商:Taylor & Francis Group
年代:1992
数据来源: Taylor
|
6. |
Book Reviews |
|
Architectural Science Review,
Volume 35,
Issue 3,
1992,
Page 107-108
Preview
|
PDF (237KB)
|
|
ISSN:0003-8628
DOI:10.1080/00038628.1992.9696723
出版商:Taylor & Francis Group
年代:1992
数据来源: Taylor
|
7. |
Instructions to Authors |
|
Architectural Science Review,
Volume 35,
Issue 3,
1992,
Page 109-109
Preview
|
PDF (112KB)
|
|
ISSN:0003-8628
DOI:10.1080/00038628.1992.9696724
出版商:Taylor & Francis Group
年代:1992
数据来源: Taylor
|
8. |
Editorial Advisory Board |
|
Architectural Science Review,
Volume 35,
Issue 3,
1992,
Page -
Preview
|
PDF (126KB)
|
|
ISSN:0003-8628
DOI:10.1080/00038628.1992.9696717
出版商:Taylor & Francis Group
年代:1992
数据来源: Taylor
|
|