|
1. |
Forthcoming conferences&meetings |
|
X‐Ray Spectrometry,
Volume 3,
Issue 4,
1974,
Page 27-27
Preview
|
PDF (55KB)
|
|
ISSN:0049-8246
DOI:10.1002/xrs.1300030413
出版商:Wiley Subscription Services, Inc., A Wiley Company
年代:1974
数据来源: WILEY
|
2. |
Microprobe analysis. C.A. Andersen (Ed.), Wiley Interscience, 1973. $24.95 |
|
X‐Ray Spectrometry,
Volume 3,
Issue 4,
1974,
Page 28-28
J. D. Brown,
Preview
|
PDF (119KB)
|
|
ISSN:0049-8246
DOI:10.1002/xrs.1300030415
出版商:Wiley Subscription Services, Inc., A Wiley Company
年代:1974
数据来源: WILEY
|
3. |
Conferences |
|
X‐Ray Spectrometry,
Volume 3,
Issue 4,
1974,
Page 29-30
Preview
|
PDF (268KB)
|
|
ISSN:0049-8246
DOI:10.1002/xrs.1300030416
出版商:Wiley Subscription Services, Inc., A Wiley Company
年代:1974
数据来源: WILEY
|
4. |
News and events |
|
X‐Ray Spectrometry,
Volume 3,
Issue 4,
1974,
Page 31-34
Preview
|
PDF (843KB)
|
|
ISSN:0049-8246
DOI:10.1002/xrs.1300030417
出版商:Wiley Subscription Services, Inc., A Wiley Company
年代:1974
数据来源: WILEY
|
5. |
Editorial |
|
X‐Ray Spectrometry,
Volume 3,
Issue 4,
1974,
Page 135-135
Ron Jenkins,
Preview
|
PDF (52KB)
|
|
ISSN:0049-8246
DOI:10.1002/xrs.1300030402
出版商:Wiley Subscription Services, Inc., A Wiley Company
年代:1974
数据来源: WILEY
|
6. |
Préparation Automatisée de Perles pour l'Analyse par la Fluorescence de Rayons X |
|
X‐Ray Spectrometry,
Volume 3,
Issue 4,
1974,
Page 137-142
A. Wittmann,
J. Chmeleff,
H. Herrmann,
Preview
|
PDF (1380KB)
|
|
摘要:
AbstractDescription d'un appareil automatique de préparation des échantillons pour l'analyse par fluorescence de rayons X, La technique est basée sur la mise en soluation solide de l'échantillon en uve de l'obtention d'une perle directement analysable.L'appreil est composé de deux fours HF, I'un pourla fusion, I'autre pour la coulée Les récipients de fusion et de coulée sont en alliage platine+ or+ rhodium. La seéquence automatique de préparation dure huit minutes.Une application á I'anlyse de minerais de fer reches par miscen solution dens le tétraborate de sodium illustre les reproductibilités de préparation que I'on peut atteindre avec ce matériel (écart type de reproductibiliteé égal á 0,15% de Fe
ISSN:0049-8246
DOI:10.1002/xrs.1300030403
出版商:Wiley Subscription Services, Inc., A Wiley Company
年代:1974
数据来源: WILEY
|
7. |
X‐ray spectrometry of Al + Ni powder compacts and alloy thin films |
|
X‐Ray Spectrometry,
Volume 3,
Issue 4,
1974,
Page 143-148
D. Duz̆ević,
T. Gaćes̆a,
Preview
|
PDF (575KB)
|
|
摘要:
AbstractThis paper reports on expeeriments to determine the composition of thin aluminium + nickel films. The techniques used were similar to those described by both Rhodin and Weyl but for reasons of simplification of the calculations involved, the effective wavelength concept was employed. Fluorescence measurements were also made on aluminium + nickel powder compacts of known composition. The comparison of measured intensities from powder compacts and thin films revealed a strong particle size intensity dependence.
ISSN:0049-8246
DOI:10.1002/xrs.1300030404
出版商:Wiley Subscription Services, Inc., A Wiley Company
年代:1974
数据来源: WILEY
|
8. |
Kβ/Kα intensity ratios for elements of atomic number 20 to 30 |
|
X‐Ray Spectrometry,
Volume 3,
Issue 4,
1974,
Page 149-150
D. G. W. Smith,
S. J. B. Reed,
N. G. Ware,
Preview
|
PDF (164KB)
|
|
摘要:
AbstractTwenty‐five new measurements of Kβ/Kα X‐ray intensity ratios for elements in the atomic number range 20 to 30 confirm other recent evidence that the variation with atomic number in this region is much less than previously thought, but there is still some disagreement for atomic numbers above 27. A table of recommended values is
ISSN:0049-8246
DOI:10.1002/xrs.1300030405
出版商:Wiley Subscription Services, Inc., A Wiley Company
年代:1974
数据来源: WILEY
|
9. |
A time saving approach to peak spectra analysis |
|
X‐Ray Spectrometry,
Volume 3,
Issue 4,
1974,
Page 151-152
R. Grote,
C. R. Cothern,
Preview
|
PDF (221KB)
|
|
摘要:
AbstractIn X‐ray fluorescence, as well as other quantitative methods for determining trace metal concentrations, computer methods for extracting characteristic peaks from background are very important. Cases where background is large and nonlinear, or there are overlapping peaks, present difficulties in the development of simple computer programs which give an accurate analysis of the peak. The method of analysis that will be described here was developed to meet these demands. The basic concept is simple, and good accuracy and reproducibility are achieved in samples with large nonlinear background, as well as overlapping peaks. The analysis is essentially independent of backgroun
ISSN:0049-8246
DOI:10.1002/xrs.1300030406
出版商:Wiley Subscription Services, Inc., A Wiley Company
年代:1974
数据来源: WILEY
|
10. |
Quantitative analysis with an energy‐dispersive detector using a pulsed electron probe and active signal filtering |
|
X‐Ray Spectrometry,
Volume 3,
Issue 4,
1974,
Page 153-158
P. J. Statham,
J. V. P. Long,
G. White,
K. Kandiah,
Preview
|
PDF (519KB)
|
|
摘要:
AbstractThe pulsed beam technique has been used to achieved a high data acuumulation rate in an energy‐dispersive analytical system consisting of an electron probe analyser and the Harwell ‘Highspec’ pulse analyser system 3074. The use of fast beam switching ( ∼ 30 ns transient time) and the special timing facilities available in the Harwell equipment reduce the spectrum contamination due to displacement of the probe during switching to a low level and also provide precise measurements of live time, essential for accurate analysis. Analyses performed at spectrumaccumulationrate of up to 12 kP.P.S. shows agreement with accepted values to within ± 1% for major constituents. Simple modification of the system permits accumulation rates up to 2
ISSN:0049-8246
DOI:10.1002/xrs.1300030407
出版商:Wiley Subscription Services, Inc., A Wiley Company
年代:1974
数据来源: WILEY
|
|