1. |
Editorial |
|
X‐Ray Spectrometry,
Volume 13,
Issue 4,
1984,
Page 147-147
Ron Jenkins,
Preview
|
PDF (43KB)
|
|
ISSN:0049-8246
DOI:10.1002/xrs.1300130402
出版商:Wiley Subscription Services, Inc., A Wiley Company
年代:1984
数据来源: WILEY
|
2. |
Melted sample (glass disk) ageing and its usability for x‐ray emission spectrometry |
|
X‐Ray Spectrometry,
Volume 13,
Issue 4,
1984,
Page 148-150
V. J. Novosel‐Radović,
D. A. Maljković,
N. Nenadić,
Preview
|
PDF (317KB)
|
|
摘要:
AbstractThe usability of glass disks prepared from blast furnace slag samples as a function of age in x‐ray emission spectrometry was investigated. Glass disks were prepared by melting sample and flux mixtures (Li2B4O7–Li2CO3–La2O3, 100: 10: 5) in the ratio 1: 100 at 1100°C for 30 min. The glass disks were examined by the ISIJ test. X‐ray spectrometry and scanning electron microscopy were applied directly after preparation and again after 6, 12 and 18 months. A change in the surface of the glass disk and a decrease in the Ca Kα, Si Kα and S Kα line intensities with time we
ISSN:0049-8246
DOI:10.1002/xrs.1300130403
出版商:Wiley Subscription Services, Inc., A Wiley Company
年代:1984
数据来源: WILEY
|
3. |
Determination of the ash content of coal by multi‐element x‐ray fluorescence analysis |
|
X‐Ray Spectrometry,
Volume 13,
Issue 4,
1984,
Page 151-152
Bohdan Dziunikowski,
Aleksander Stochalski,
Preview
|
PDF (138KB)
|
|
摘要:
AbstractA method for determining the ash content of coal by measuring the x‐ray fluorescence of Si, Al, Ca and Fe using a diffraction spectrometer is presented. The experiments were carried out on 72 samples of coal from different deposits. A mean standard deviation of the ash content of about 1. 65% was achieve
ISSN:0049-8246
DOI:10.1002/xrs.1300130404
出版商:Wiley Subscription Services, Inc., A Wiley Company
年代:1984
数据来源: WILEY
|
4. |
Study of some cobalt biomolecular complexes by x‐ray absorption spectroscopy |
|
X‐Ray Spectrometry,
Volume 13,
Issue 4,
1984,
Page 153-155
S. Chattopadhyay,
V. B. Sapre,
C. Mande,
Preview
|
PDF (233KB)
|
|
摘要:
AbstractThe fine structure in the vicinity of the K absorption edge of cobalt in some cobalt biomolecular complexes has been studied using a bent crystal x‐ray spectrograph of the Cauchois type. The average metal—ligand bond length in these complexes has been determined by applying Levy's the
ISSN:0049-8246
DOI:10.1002/xrs.1300130405
出版商:Wiley Subscription Services, Inc., A Wiley Company
年代:1984
数据来源: WILEY
|
5. |
X‐ray K absorption edges of cobalt and copper in their tetraphenylporphyrin (TPP) and formate di‐ and tetrahydrate (FDH) (FTH) compounds |
|
X‐Ray Spectrometry,
Volume 13,
Issue 4,
1984,
Page 156-158
O. P. Rajput,
A. N. Nigam,
B. D. Shrivastava,
Preview
|
PDF (287KB)
|
|
摘要:
AbstractK absorption edge data for TPP and FDH compounds of cobalt and copper have been recorded. Edge position shifts, changes in edge widths and shifts in the position of first absorption maximum are discussed.
ISSN:0049-8246
DOI:10.1002/xrs.1300130406
出版商:Wiley Subscription Services, Inc., A Wiley Company
年代:1984
数据来源: WILEY
|
6. |
Quantitative analysis of bulk samples without standards by using peak‐to‐background ratios |
|
X‐Ray Spectrometry,
Volume 13,
Issue 4,
1984,
Page 159-165
J. Heckel,
P. Jugelt,
Preview
|
PDF (603KB)
|
|
摘要:
AbstractA method is described for the quantitative analysis of bulk specimens without standards by using peak‐to‐local background ratios in energy‐dispersive electron probe microanalysis. Theoretical transport investigations have been used to derive an expression for the absolute determination of (P/B) ratios. Accurate measurement of the background below a peak is carried out without an exact knowledge of the surface geometry of the specimens. The advantages of this method are discussed in comparison with other correction procedures and the efficiency is demonstrated by means of quantitative analysis of nine binary specimens and two steel spec
ISSN:0049-8246
DOI:10.1002/xrs.1300130407
出版商:Wiley Subscription Services, Inc., A Wiley Company
年代:1984
数据来源: WILEY
|
7. |
Theoretical evalution of the efficiency of compton scattered radiation method in EDXRF analysis |
|
X‐Ray Spectrometry,
Volume 13,
Issue 4,
1984,
Page 166-169
Andrzej Markowicz,
Preview
|
PDF (336KB)
|
|
摘要:
AbstractA theoretical evaluation of the efficiency of correction for the matrix absorption effect using Compton scattered x‐rays in EDXRF analysis has been carried out for thick samples and for monoenergetic primary radiation. The limitations of this correction method and the procedure for the selection of the optimum excitation energy are presente
ISSN:0049-8246
DOI:10.1002/xrs.1300130408
出版商:Wiley Subscription Services, Inc., A Wiley Company
年代:1984
数据来源: WILEY
|
8. |
Non‐destructive measurement of gas pressures in sealed halogen lamps by x‐ray spectrometry |
|
X‐Ray Spectrometry,
Volume 13,
Issue 4,
1984,
Page 170-171
P. Lublin,
F. Pink,
C. Persiani,
Preview
|
PDF (220KB)
|
|
摘要:
AbstractX‐ray spectrometry has been used to determine the pressure of krypton gas in high‐pressure halogen auto lamps. The method employs a standard diffraction tube, a special collimator and a solid‐state det
ISSN:0049-8246
DOI:10.1002/xrs.1300130409
出版商:Wiley Subscription Services, Inc., A Wiley Company
年代:1984
数据来源: WILEY
|
9. |
PDIDENT—a set of programs for powder diffraction phase identification |
|
X‐Ray Spectrometry,
Volume 13,
Issue 4,
1984,
Page 172-179
Raymond P. Goehner,
Mary F. Garbauskas,
Preview
|
PDF (859KB)
|
|
摘要:
AbstractPDIDENT is a collection of interactive computer programs which have been developed as aids for qualitative phase analysis of x‐ray powder diffraction data. These FORTRAN IV programs are implemented on a DEC committee on Powder Diffraction Standards (JCPDS) data base is accessed by the programs along with user‐created data. The data base (sets 1–32) along with all cross‐index files requires 9 Mbytes of storage. The packing of the data base, use of cross‐index files and the algorithms and utility of the PDIDENT programs are
ISSN:0049-8246
DOI:10.1002/xrs.1300130410
出版商:Wiley Subscription Services, Inc., A Wiley Company
年代:1984
数据来源: WILEY
|
10. |
μ/ρ Algorithm valid for 1 keV ≤E≤ 50 keV and 11 ≤Z≤ 83 |
|
X‐Ray Spectrometry,
Volume 13,
Issue 4,
1984,
Page 180-181
J. Wernisch,
C. Pöhn,
W. Hanke,
H. Ebel,
Preview
|
PDF (133KB)
|
|
摘要:
AbstractMass absorption coefficients can be calculated by this algorithm with programmable pocket calculators giving a standard deviation of about 5% when compared with McMaster's tables.
ISSN:0049-8246
DOI:10.1002/xrs.1300130411
出版商:Wiley Subscription Services, Inc., A Wiley Company
年代:1984
数据来源: WILEY
|
|