|
1. |
Effect of suture technique on blood velocity waveforms in the microvascular anastomosis of autogenous vein graft |
|
Microsurgery,
Volume 4,
Issue 3,
1983,
Page 151-156
Bok Y. Lee,
Richard F. Brancato,
William W. Shaw,
Shawn Browne,
William R. Thoden,
John L. Madden,
Preview
|
PDF (903KB)
|
|
摘要:
AbstractIn using autogenous vein grafts in microvascular surgery, maintenance of compliance at the site of anastomosis is of importance in achieving patency. Using high‐frequency, 20 MHz, pulsed Doppler ultrasonography to monitor blood flow velocity through the vein graft, we have evaluated the effects of continuous and interrupted suture technique on anastomotic compliance in vessels less than 1.5 mm in diameter. In 15 dogs, 15 procedures of each technique, using the continuous technique in one limb and the interrupted technique on the contralateral limb, patency rates for both techniques, documented by arteriography, are 100% at a mean follow‐up of 11 weeks. There were no significant differences in the blood velocity profile and pulsatility proximally, distally, and at the graft site between continuous and interrupted technique. This study confirms the suggestion that autogenous vein graft has sufficient elasticity to maintain normal arterial blood velocity wavefo
ISSN:0738-1085
DOI:10.1002/micr.1920040302
出版商:Wiley Subscription Services, Inc., A Wiley Company
年代:1983
数据来源: WILEY
|
2. |
The use of microvascular graft as an arterial substitute in the abdominal aorta of the rat |
|
Microsurgery,
Volume 4,
Issue 3,
1983,
Page 157-163
Oskar Zelder,
Heinz Helmut Werner,
Christoph R. Jerusalem,
Preview
|
PDF (3160KB)
|
|
摘要:
AbstractThe purpose of this study was to compare by means of microsurgical techniques a porous with an interiorly smooth siliconized vascular graft. Compatibility and patency of the graft were examined in a long term followup. A microvascular prosthesis with a particular fibrous texture was used. The fibres consisted of polyurethane (PUR), a new prosthetic material. The lumen of the prosthesis measured 1.6 mm; the outer diameter was 2.4 mm. In group A an in‐ and exteriorly microporous graft was applied; in group B the inner surface of the prosthesis was smoothed by a silicon layer. 30 SPFWistar rats were randomized in group A (n = 15) and B (n = 15), and both prosthetic materials were implanted as a substitute for an infrarenal part of the abdominal aorta. Monofile suture material (MirafilR—DR 5) size 10:0 was used for the anastomosis. The mean pressure of the aorta amounted to 108 ± 30 mm Hg. After 4 ± 2 months the total survival rate was 77% (n = 23): in group A, 80% (n = 12); in group B, 73% (n = 11). Cause of death was early thrombosis due to technical mistakes. The following results were obtained by angiography: highest patency—group A, 8; group B, 1; constriction—group A, 6; group B, 9; occlusion—group A, 1; group B, 4; total—group A, 15; group B, 14; 1 angiography technically failed. Arterial substitution in the abdominal aorta of the rat by PUR‐grafts is possible and is a suitable model for further experiments. Prosthetic material with porous structure is significantly better than that with an impermeable smooth inner surface (significance 10%, test by Bross13). The low number of experiments allows only trend information and therefore must be considered as a pilot study, though histopathological findings undoubtly point to the superiority of the porous texture of the vasc
ISSN:0738-1085
DOI:10.1002/micr.1920040303
出版商:Wiley Subscription Services, Inc., A Wiley Company
年代:1983
数据来源: WILEY
|
3. |
Comparison of two laser Doppler flowmeters for the monitoring of dermal blood flow |
|
Microsurgery,
Volume 4,
Issue 3,
1983,
Page 164-170
Joseph C. Fischer,
Paul M. Parker,
William W. Shaw,
Preview
|
PDF (772KB)
|
|
摘要:
AbstractLaser Doppler flowmetry (LDF) is a noninvasive and continuous method of monitoring dermal blood flow in free flaps. There are two LDFs available for clinical application: the LD5000 Laser Doppler Perfusion Monitor and the Periflux Laser Doppler Flowmeter. Varying degrees of arterial (N = 46) and venous (N = 28) occlusion were induced in saphenous island flaps of the dog, while simultaneous measurements with the LD5000 and Periflux LDFs were made. The millivoltage output of both the LD5000 and the Periflux showed a high degree of correlation with arterial and venous occlusion and with each other.
ISSN:0738-1085
DOI:10.1002/micr.1920040304
出版商:Wiley Subscription Services, Inc., A Wiley Company
年代:1983
数据来源: WILEY
|
4. |
A new anastomosis technique for large‐calibered vein grafts |
|
Microsurgery,
Volume 4,
Issue 3,
1983,
Page 171-175
Takao Harashina,
Jose Louis Takaki,
Preview
|
PDF (1486KB)
|
|
摘要:
AbstractA new anastomosis technique for large‐calibered vein graft to repair a smallersized arterial defect is presented. At the proximal (upstream) anastomosis, a combination of sleeve anastomosis technique and plication of excess vessel wall is performed; and at the distal (downstream) anastomosis, the “fishmouth” incision technique is used. The patency rate obtained with this technique is quite satisfactory, which justifies its use in clinical situa
ISSN:0738-1085
DOI:10.1002/micr.1920040305
出版商:Wiley Subscription Services, Inc., A Wiley Company
年代:1983
数据来源: WILEY
|
5. |
The effect of stasis on a microvascular anastomosis |
|
Microsurgery,
Volume 4,
Issue 3,
1983,
Page 176-177
Enrique J. Fernandez,
Richard D. Nadal,
Sandy M. Gonzalez,
H. Hollis Caffee,
Preview
|
PDF (220KB)
|
|
摘要:
AbstractAn experiment was done in rats to determine the effect of stopping the flow of blood across a fresh anastomosis. It was found that brief periods of stasis, up to 30 minutes, caused a minimal increase in the rate of thrombosis, but 60 minutes of stasis caused a significant risk of thrombosis in both arteries and veins. The thrombosis associated with stasis could be prevented by the systemic administration of heparin.
ISSN:0738-1085
DOI:10.1002/micr.1920040306
出版商:Wiley Subscription Services, Inc., A Wiley Company
年代:1983
数据来源: WILEY
|
6. |
Evaluation of the patency rate of fibrous microvascular polyurethane prostheses after implantation in the rat aorta |
|
Microsurgery,
Volume 4,
Issue 3,
1983,
Page 178-181
Frits Hess,
Christoph Jerusalem,
Bernd Braun,
Peter Grande,
Preview
|
PDF (1150KB)
|
|
摘要:
AbstractTwo types of fibrous polyurethane prostheses with different compliances were implanted into the rat aorta with interrupted sutures and a running suture line. Excluding two technical failures, one unexplained death, and three infected prostheses, both groups (n = 21) showed a patency rate of 100%, up to 6 months after implantation. Rapid reendothelialisation occurred, and a stable neo‐intima was formed. Compliance of the prostheses, as well as the suture technique used, has proven to be an unimportant factor in the rat aorta model, probably due to the low magnitude of the pulsations of the rat aorta. The experience of the surgeon with microsurgical techniques seems to be an underestimated factor in determining patency rates of microvascular prosthese
ISSN:0738-1085
DOI:10.1002/micr.1920040307
出版商:Wiley Subscription Services, Inc., A Wiley Company
年代:1983
数据来源: WILEY
|
7. |
The hand table for pediatric microsurgery |
|
Microsurgery,
Volume 4,
Issue 3,
1983,
Page 182-182
Hani S. Matloub,
Thomas P. Trevisani,
James R. Sanger,
Preview
|
PDF (72KB)
|
|
摘要:
AbstractThe technique using the hand table for positioning of infants for microsurgical procedures of the lower extremity is presented. With this technique, the surgeon and assistant are able to sit directly opposite each other with their arms in stable resting position.
ISSN:0738-1085
DOI:10.1002/micr.1920040308
出版商:Wiley Subscription Services, Inc., A Wiley Company
年代:1983
数据来源: WILEY
|
8. |
A stereomicroscopic system modified for microsurgical laboratory |
|
Microsurgery,
Volume 4,
Issue 3,
1983,
Page 183-186
Jiri Smahel,
Donald L. Ballantyne,
Preview
|
PDF (1077KB)
|
|
摘要:
AbstractAn operating table stand incorporating a rotatable mechanical surface with a motorized focusing stage carrier was designed for a standard stereomicroscope. This can be used for microsurgical experiments and practicing microsurgical techniques in small laboratory animals.
ISSN:0738-1085
DOI:10.1002/micr.1920040309
出版商:Wiley Subscription Services, Inc., A Wiley Company
年代:1983
数据来源: WILEY
|
9. |
Physiologic tremor and microsurgery |
|
Microsurgery,
Volume 4,
Issue 3,
1983,
Page 187-192
Richard C. Harwell,
R. Lawrence Ferguson,
Preview
|
PDF (702KB)
|
|
摘要:
AbstractPhysiologic tremor hampers the ability of students to learn microsurgical technique. An understanding of normal tremor both as to origin and methods of control would be of help. Physiological tremor arises from both mechanical and neuromuscular sources and is made worse by a number of factors. The “size principle of motoneuron recruitment” is an important physiologic consideration, and the use of biofeedback techniques enables the student to confirm his understanding of the principle. Knowledge of the factors which aggravate physiological tremor allows the microsurgeon to control his own tremor both in the laboratory and in the operating r
ISSN:0738-1085
DOI:10.1002/micr.1920040310
出版商:Wiley Subscription Services, Inc., A Wiley Company
年代:1983
数据来源: WILEY
|
10. |
A scanning electron microscopic study of microvascular anastomoses on irradiated vessels: Short‐term effect of irradiation |
|
Microsurgery,
Volume 4,
Issue 3,
1983,
Page 193-200
R. De Wilde,
W. Boeckx,
E. Van Der Schueren,
P. Guelinckx,
J. Gruwez,
Preview
|
PDF (4514KB)
|
|
摘要:
AbstractExperiments were carried out to determine the effect of previous irradiation on microvascular arterial anastomoses. The study focused on regeneration of endothelial cells and thrombus formation. Careful examination with scanning electron microscopy (SEM) showed a difference between irradiated animals and a control group. In the irradiated group one can notice a decreased regeneration, a greater amount of fibrin and platelets, and a higher incidence of microthrombi.
ISSN:0738-1085
DOI:10.1002/micr.1920040311
出版商:Wiley Subscription Services, Inc., A Wiley Company
年代:1983
数据来源: WILEY
|
|