|
1. |
A liberal spirit and an honest mind |
|
Microsurgery,
Volume 1,
Issue 6,
1980,
Page 417-418
R. M. Peardon Donaghy,
Preview
|
PDF (100KB)
|
|
ISSN:0738-1085
DOI:10.1002/micr.1920010602
出版商:Wiley Subscription Services, Inc., A Wiley Company
年代:1980
数据来源: WILEY
|
2. |
The operating microscope. II. Individual parts, handling, assembling, focusing, and balancing |
|
Microsurgery,
Volume 1,
Issue 6,
1980,
Page 419-427
Peter Hoerenz,
Preview
|
PDF (1745KB)
|
|
摘要:
AbstractThe major components of the Zeiss OPMI 1, OPMI 6‐S, and OPMI 7 P/H are discussed along with details on handling and assembling the components, changing couplings, focusing, and balancing the microscope system prior to us
ISSN:0738-1085
DOI:10.1002/micr.1920010603
出版商:Wiley Subscription Services, Inc., A Wiley Company
年代:1980
数据来源: WILEY
|
3. |
Microsurgery in andrologic urology. II. Alloplastic spermatocele |
|
Microsurgery,
Volume 1,
Issue 6,
1980,
Page 428-435
L. V. Wagenknecht,
K. H. Weitze,
L. P. Hoppe,
D. Krause,
H. Becker,
C. Schirren,
Preview
|
PDF (1492KB)
|
|
摘要:
AbstractExperimental studies in rats and bulls demonstrated the feasibility of using a silicone‐Dacron prosthesis as a sperm reservoir in cases of excretory azoospermia. In the study in bulls, 50% of the cows inseminated with spermatozoa aspirated from the alloplastic spermatocele conceived and delivered healthy calves. The clinical results of a series of 14 humans suffering from excretory azoospermia not treatable by other means (e.g., epididymovasostomy or vasovasostomy) also are presented. The aspirations from these spermatoceles produced motile spermatozoa; however, none of the patients' spouses conceived after inseminatio
ISSN:0738-1085
DOI:10.1002/micr.1920010604
出版商:Wiley Subscription Services, Inc., A Wiley Company
年代:1980
数据来源: WILEY
|
4. |
Sutureless microvascular anastomosis using a neodymium‐yag laser |
|
Microsurgery,
Volume 1,
Issue 6,
1980,
Page 436-439
Kewal K. Jain,
Preview
|
PDF (1082KB)
|
|
摘要:
AbstractA technique is described in which a Neodymium‐YAG laser is used to anastomose arteries 0.8 to 1.0 mm in diameter. Heat generated by the laser causes fusion of the collagen of the media, making direct handling of the vessel wall unnecessary. Four variations of the technique were performed in 120 rat carotid arteries. Angiographic and scanning electron microscopic studies were carried out immediately after surgery and at intervals of 1 day to 6 months after anastomosis. Patency rates as high as 92.5% were recorded. The technique that produced the most secure anastomosis was considered to be one in which a vascular strut was used as an aid in apposition, followed by the application of a piece of vein wall to the anastomosis with tissue adhesive. The main advantages of the laser technique are speed and consistency. Complications such as disruption and aneurysm formation are considered to be rar
ISSN:0738-1085
DOI:10.1002/micr.1920010605
出版商:Wiley Subscription Services, Inc., A Wiley Company
年代:1980
数据来源: WILEY
|
5. |
The effect of hepatic interposition on ovary‐pituitary interaction |
|
Microsurgery,
Volume 1,
Issue 6,
1980,
Page 440-446
Sun Lee,
James G. Chandler,
Christoph E. Broelsch,
Yoichi Ehara,
James K. Condon,
A. Crane Charters,
Samuel S. C. Yen,
Marshall J. Orloff,
Preview
|
PDF (661KB)
|
|
摘要:
AbstractWhen the livers of female rats were provided with exclusive first access to all ovarian venous effluents by simultaneous castration and implantation of a portion of one of the ovaries beneath the splenic capsule, systemic venous plasma concentrations of estrone and estradiol were reduced 40%. Paradoxically, progestins in the peripheral plasma increased threefold, most probably because of augmented adrenocortical progestin secretion. Nevertheless, the change in estrogen levels alone was sufficient to abolish trophic effects on the genital organs and to block normal inhibition of pituitary gonadotropin secretion. Plasma gonadotropin concentrations were markedly elevated to levels comparable to those of castrates, and, as a result, the intrasplenic ovarian implants grew excessively and became histologically disorganized. A patent portacaval shunt negated the entire process, providing proof that the measured hormonal alterations and the change in the implant itself were direct consequences of hepatic screening.
ISSN:0738-1085
DOI:10.1002/micr.1920010606
出版商:Wiley Subscription Services, Inc., A Wiley Company
年代:1980
数据来源: WILEY
|
6. |
Expanded polytetrafluoroethylene as a microvascular graft: An experimental study |
|
Microsurgery,
Volume 1,
Issue 6,
1980,
Page 447-456
Disa H. Lidman,
Burt Faibisoff,
Rollin K. Daniel,
Preview
|
PDF (2686KB)
|
|
摘要:
AbstractThe patency rates of expanded polytetrafluoroethylene (PTFE) vascular grafts with internal diameters of 1.0–3.0 mm were evaluated in three different species (dogs, rabbits, and rats). An overall 2‐week patency rate of 14 (23%) of 60 was obtained, with the exception of 10 (83%) of 12 grafts 1.8 mm in diameter inserted in the carotid arteries of rabbits. The presence of numerous variables in the structural properties of PTFE may explain the variable results reported in the literature and this study. Heparinization did not improve the results, nor did modification in suture technique. At the present time, PTFEcannotbe considered an equivalent to or a substitute for autogenous vein grafts in microvascular surg
ISSN:0738-1085
DOI:10.1002/micr.1920010607
出版商:Wiley Subscription Services, Inc., A Wiley Company
年代:1980
数据来源: WILEY
|
7. |
Spontaneous cervical epidural hemorrhage, anterior cord syndrome, and familial vascular malformations: Case report |
|
Microsurgery,
Volume 1,
Issue 6,
1980,
Page 457-460
Dominic Foo,
Young C. Chang,
Alain B. Rossier,
Preview
|
PDF (855KB)
|
|
摘要:
AbstractComplete motor tetraplegia with incomplete sensory loss was caused by spontaneous epidural bleeding from an arteriovenous malformation in the cervical region. There was a family and personal history of cutaneous hemangioma.
ISSN:0738-1085
DOI:10.1002/micr.1920010608
出版商:Wiley Subscription Services, Inc., A Wiley Company
年代:1980
数据来源: WILEY
|
8. |
Editorial comment |
|
Microsurgery,
Volume 1,
Issue 6,
1980,
Page 461-461
R. M. P. Donaghy,
Preview
|
PDF (96KB)
|
|
ISSN:0738-1085
DOI:10.1002/micr.1920010609
出版商:Wiley Subscription Services, Inc., A Wiley Company
年代:1980
数据来源: WILEY
|
9. |
Intramuscular urography in rats |
|
Microsurgery,
Volume 1,
Issue 6,
1980,
Page 462-464
Alfred J. Lamesch,
Bernard Schreiner,
Preview
|
PDF (1309KB)
|
|
摘要:
AbstractIn addition to macroscopic studies, microscopic studies, and biologic tests, urography is a valuable method for investigating renal function in rats. Intravenous urography is complicated, however, by the difficulty of puncturing a tail vein or the femoral vein. Intramuscular urography, on the other hand, is a simple and reliable method for radiographic examination of the kidneys and ureters, and gives information on morphology as well as physiology. In this study in 40 rats, intramuscular urography was performed under general anesthesia, and the contrast medium was injected into the gluteal muscles. Dense nephrograms and optimum films of the calices and the ureters were obtained approximately 40 minutes after injection.
ISSN:0738-1085
DOI:10.1002/micr.1920010610
出版商:Wiley Subscription Services, Inc., A Wiley Company
年代:1980
数据来源: WILEY
|
10. |
A new clamp for end‐to‐side microvascular anastomosis |
|
Microsurgery,
Volume 1,
Issue 6,
1980,
Page 465-469
Se‐Min Baek,
Julyus H. Jacobson,
Preview
|
PDF (1430KB)
|
|
摘要:
AbstractA new clamp for use in microvascular end‐to‐side anastomosis is described. The advantages of the clamp are that the end of the donor vessel is placed precisely over the opening of the recipient vessel without tension, good exposure of the posterior wall is provided, and the tension on the stay sutures is easily adjus
ISSN:0738-1085
DOI:10.1002/micr.1920010611
出版商:Wiley Subscription Services, Inc., A Wiley Company
年代:1980
数据来源: WILEY
|
|