1. |
Toward a unified view of radiological imaging systems. Part II: Noisy images |
|
Medical Physics,
Volume 4,
Issue 4,
1998,
Page 279-296
Robert F. Wagner,
Preview
|
PDF (1820KB)
|
|
摘要:
“The imaging process is fundamentally a sampling process.” This philosophy of Otto Schade, utilizing the concepts of sample number and sampling aperture, is applied to a systems analysis of radiographic imaging, including some aspects of vision. It leads to a simple modification of the Rose statistical model; this results in excellent fits to the Blackwell data on the detectability of disks as a function of contrast and size. It gives a straightforward prescription for calculating a signal‐to‐noise ratio, which is applicable to the detection of low‐contrast detail in screen–film imaging, including the effects of magnification. The model lies between the optimistic extreme of the Rose model and the pessimistic extreme of the Morgan model. For high‐contrast detail, the rules for the evaluation of noiseless images are recovered.
ISSN:0094-2405
DOI:10.1118/1.594362
出版商:American Association of Physicists in Medicine
年代:1998
数据来源: WILEY
|
2. |
Flattening of proton dose distributions for large‐field radiotherapy |
|
Medical Physics,
Volume 4,
Issue 4,
1998,
Page 297-301
A. M. Koehler,
R. J. Schneider,
J. M. Sisterson,
Preview
|
PDF (398KB)
|
|
摘要:
Methods for obtaining flattened charged‐particle dose distributions over large areas are described. The system being used at Harvard for proton radiotherapy is discussed in detail. It is an extension of usual multiple‐scattering techniques to include blocking out some of the central peak, followed by rescattering to fill in the profile, resulting in flat distributions up to 30 cm in diameter. The unusually long source‐to‐skin distance (4.6‐m SSD) plus the small lateral spread (2 mm rms) from multiple scattering in the patient results in little divergence of the beam throughout the treatment volume.
ISSN:0094-2405
DOI:10.1118/1.594317
出版商:American Association of Physicists in Medicine
年代:1998
数据来源: WILEY
|
3. |
Imaging soft tissue through bone with ultrasound transmission tomography by reconstruction |
|
Medical Physics,
Volume 4,
Issue 4,
1998,
Page 302-309
Paul L. Carson,
Thomas V. Oughton,
William R. Hendee,
Avtar S. Ahuja,
Preview
|
PDF (956KB)
|
|
摘要:
A phantom consisting of a 2.5‐cm‐diameter aluminum rod, a balloon filled with castor oil, and a balloon filled with a phenylated silicone fluid was imaged in water with ultrasound transmission tomography by reconstruction (UTTR). This phantom was chosen for investigation of the feasibility of detecting small changes in the ultrasound velocity and ultrasound attenuation coefficient of soft tissues in planes containing bones. Attenuation images of a transverse section of a leg of lamb were obtained as well. Opposed transmitting and receiving transducers were scannned on either side of the imaged object, just as an x‐ray tube and detector are scanned in the pencil beam geometry employed with the first x‐ray computerized axial tomographic system. More than adequate signal was transmitted through the aluminum rod and the bone to obtain reconstructions; but, in these crude images, there were numerous artifacts which maintain the uncertainty regarding the future utility of this promising technique. Although velocity imaging should not be as sensitive to reflection and refraction as attenuation imaging, a very narrow ultrasound beam must be employed to obtain reasonable resolution in velocity imaging.
ISSN:0094-2405
DOI:10.1118/1.594318
出版商:American Association of Physicists in Medicine
年代:1998
数据来源: WILEY
|
4. |
Scattered photons as the cause for the observeddmaxshift with field size in high‐energy photon beams |
|
Medical Physics,
Volume 4,
Issue 4,
1998,
Page 310-314
James R. Marbach,
Peter R. Almond,
Preview
|
PDF (379KB)
|
|
摘要:
Measurements on the Sagittaire linear accelerator and Allis–Chalmers betatron at M. D. Anderson Hospital indicate that the observeddmaxshift with field size is due to the presence of Compton‐scattered photons in the therapy beam, and not electrons as proposed by others. Separating the primary from other radiation components indicates that the secondary fraction represents a percentage contribution to the overall beam that increases as the collimators are opened. This is consistent with what would be expected from Compton scattering and explains the effective softening of the beam as field size increases.
ISSN:0094-2405
DOI:10.1118/1.594319
出版商:American Association of Physicists in Medicine
年代:1998
数据来源: WILEY
|
5. |
Dosimeter placement in the Rando phantom |
|
Medical Physics,
Volume 4,
Issue 4,
1998,
Page 315-318
Benjamin R. Archer,
Sharon Glaze,
Luceil B. North,
Stewart C. Bushong,
Preview
|
PDF (289KB)
|
|
摘要:
Each section of the Alderson Rando phantom contains a tissue‐equivalent plastic coating layer approximately 2 mm thick, applied to both faces. This compensates for material removed in the sawing process. Conventional use of thermoluminescent dosimeters positions them totally or partially within the coating layer. Analysis shows that, in the lung region, dosimeters placed in this layer received a dose averaging 39% lower than those placed at midsection. Where bony structures interfere, some dosimeters in the coating layer received an 18% higher dose than those at midsection. Therefore, positioning dosimeters at the center of a section is recommended.
ISSN:0094-2405
DOI:10.1118/1.594320
出版商:American Association of Physicists in Medicine
年代:1998
数据来源: WILEY
|
6. |
Dosimetric measurements in the neutron field produced by a deuterium gas target with a compact medical cyclotron |
|
Medical Physics,
Volume 4,
Issue 4,
1998,
Page 319-321
Joseph C. McDonald,
Thomas Y. T. Kuo,
Barry R. Freed,
John S. Laughlin,
Preview
|
PDF (252KB)
|
|
摘要:
Several dosimetric measurements have been carried out in the neutron field produced by accelerated deuterons incident upon a pressurized deuterium gas target. A significant improvement has been achieved in central‐axis depth dose when compared to the9Be(3He,n)11C interaction previously studied. Designs for a target with a high‐power dissipation capability are currently underway.
ISSN:0094-2405
DOI:10.1118/1.594321
出版商:American Association of Physicists in Medicine
年代:1998
数据来源: WILEY
|
7. |
Neutron spectra at 0° from 83.7‐MeV deuterons and 100.2‐MeV protons on beryllium |
|
Medical Physics,
Volume 4,
Issue 4,
1998,
Page 322-323
R. Madey,
F. M. Waterman,
A. R. Baldwin,
Preview
|
PDF (116KB)
|
|
摘要:
Neutron energy spectra were measured at 0° from 83.7‐MeV deuteron bombardment of a 2.0‐cm‐thick beryllium target and 100.2‐MeV proton bombardment of a 60‐MeV‐thick beryllium target backed with aluminum.
ISSN:0094-2405
DOI:10.1118/1.594316
出版商:American Association of Physicists in Medicine
年代:1998
数据来源: WILEY
|
8. |
Calendar |
|
Medical Physics,
Volume 4,
Issue 4,
1998,
Page 325-325
Joan Seibert,
Preview
|
PDF (79KB)
|
|
ISSN:0094-2405
DOI:10.1002/j.2473-4209.1977.tb36091.x
出版商:Wiley
年代:1998
数据来源: WILEY
|
9. |
American Association of Physicists in Medicine 19th Annual Meeting |
|
Medical Physics,
Volume 4,
Issue 4,
1998,
Page 327-365
Preview
|
PDF (3277KB)
|
|
ISSN:0094-2405
DOI:10.1002/j.2473-4209.1977.tb36092.x
出版商:Wiley
年代:1998
数据来源: WILEY
|
10. |
Table of Contents |
|
Medical Physics,
Volume 4,
Issue 4,
1998,
Page -
Preview
|
PDF (27KB)
|
|
ISSN:0094-2405
DOI:10.1002/j.2473-4209.1977.tb36093.x
出版商:Wiley
年代:1998
数据来源: WILEY
|