11. |
Nitrous Oxide Intensifies the Pulmonary Arterial Pressure Response to Venous Injection of Carbon Dioxide in the Dog |
|
Anesthesiology,
Volume 52,
Issue 1,
1980,
Page 52-55
Eugene Steffey,
Brynte Johnson,
Edmond Eger,
Preview
|
PDF (339KB)
|
|
摘要:
To determine the effect of nitrous oxide on the body's response to venous carbon dioxide (CO2) embolization, the authors compared changes in mean pulmonary arterial pressure (MPAP) following intravenous injections of CO2in pentobarbital-anesthetized dogs breathing 100 per cent oxygen (O2) or nitrous oxide–oxygen, 79:21 per cent (N2O). When CO2was infused intravenously in seven dogs at a rate of 3 ml/kg/min the volume of injected CO2needed to increase MPAP to 40 per cent above control during breathing of O2was approximately 5.5 times the volume necessary during inhalation of N2O. In a second group of eight dogs, breathing N2O, compared with O2or air, resulted in a significantly greater increase and duration of increase in MPAP following a bolus injection of CO2of 20, 40 or 80 ml. The data suggest that breathing nitrous oxide intensifies and prolongs the effect of CO2bubbles in blood. While the magnitude of insult following intravenous injection of CO2is about 6.5 times less than that for a similar volume of air, avoidance of nitrous oxide should be considered in management of patients in whom CO2embolism is possible.
ISSN:0003-3022
出版商:OVID
年代:1980
数据来源: OVID
|
12. |
Comparison of Aortic Pulse‐wave Contour Analysis and Thermodilution Methods of Measuring Cardiac Output during Anesthesia in the Dog |
|
Anesthesiology,
Volume 52,
Issue 1,
1980,
Page 56-61
John English,
Michael Hodges,
Craig Sentker,
Richard Johansen,
Theodore Stanley,
Preview
|
PDF (473KB)
|
|
摘要:
Accuracy and reliability of cardiac output (±Qtmeasurement utilizing computer analysis of the aortic pressure wave (Warner method) were assessed by comparing this technique with a standard thermodilution method in 20 halothane-anesthetized dogs over a wide range of ±Qtand systemic vascular resistance (SVR) values. Five of the dogs also had electromagnetic flow (EMF) probes placed around the ascending aorta. More than 800 pairs of simultaneous ±Qtdeterminations were performed using pulse-wave and thermodilution methods, and more than 150 triplicate measurements made using all three techniques during changes in inspired halothane concentrations (0.5–2.0 per cent) or during infusions of sodium nitroprusside (SNP) and phenylephrine (PE). Cardiac out±puts ranged from 0.7 to 5.3 1/min, mean aortic blood pressures (BP) ranged from 30 to 200 torr, and SVR varied from 70 per cent below to 200 per cent above control values. Correlation of pulse-wave-computed and thermodilution-calculated ±Qtvalues was high (r = .91 or better), irrespective of SVR during changes in halothane concentration. Correlation of pulse-wave and EMF methods was equally good during this period (r = .92 or better). Correlation was lower, but still good, with alterations in SVR of 30 per cent or less induced by SNP or PE (r = .90 or better for thermodilution and r = .91 or better for EMF). When SVR was changed from 30 to 50 per cent of control with SNP or PE, correlation between pulse-wave-computed and EMF ±Qtvalues remained good (r = .85), but correlation between pulse-wave-computed and thermodilution-calculated ±Qtvalues was only fair (r = .79–.77). Correlation of thermodilution-calculated or EMF and pulse-wave-computed ±Qtvalues deteriorated significantly with SNP. and PE-induced changes of SVR greater than 50 per cent (r = <.5). These results demonstrate that computer analysis of the aortic pressure wave is a simple and valid method of determining ±Qtduring halothane anesthesia, but must be limited to conditions of only moderate alteration of SVR during infusions of vasopressor or vasodilator drugs.
ISSN:0003-3022
出版商:OVID
年代:1980
数据来源: OVID
|
13. |
Robert Hinckley's “The First Operation with Ether” |
|
Anesthesiology,
Volume 52,
Issue 1,
1980,
Page 62-70
Leroy Vandam,
Preview
|
PDF (691KB)
|
|
ISSN:0003-3022
出版商:OVID
年代:1980
数据来源: OVID
|
14. |
The Construction of Linear Resistances for the Testing of Ventilators |
|
Anesthesiology,
Volume 52,
Issue 1,
1980,
Page 71-73
Meyer Saklad,
Robert Weyerhaeuser,
RONALD MILLER,
Preview
|
PDF (126KB)
|
|
摘要:
This report describes the construction of a range of linear resistance units from 5 to 1,000 cm H2O/±I/sec for use in testing ventilators in accordance with theAmerican National Standards for Breathing Machines for Medical Use(ANSI Z79.7, 1976). Various filter materials housed inside a Bird water trap are employed to produce the desired resistance values. Pressure and flow measurements showed that the units were sufficiently linear (within ±20 per cent) over a flow range of from 0 to 1/l/sec.
ISSN:0003-3022
出版商:OVID
年代:1980
数据来源: OVID
|
15. |
Monitoring Neuromuscular Block May be Unreliable in Patients with Upper‐motor-neuron Lesions |
|
Anesthesiology,
Volume 52,
Issue 1,
1980,
Page 74-75
Douglas Graham,
Preview
|
PDF (153KB)
|
|
摘要:
Monitoring the degree of neuromuscular block during anesthesia has become a routine and valuable practice in the last few years.1Three recent cases have demonstrated that monitoring with the peripheral-nerve stimulator may be unreliable and misleading in patients with upper-motor-neuron lesions.
ISSN:0003-3022
出版商:OVID
年代:1980
数据来源: OVID
|
16. |
Magnesium Sulfate Prevents Succinylcholine‐induced Fasciculations in Toxemic Parturients |
|
Anesthesiology,
Volume 52,
Issue 1,
1980,
Page 76-76
Jay DeVore,
Rajkumari Asrani,
Preview
|
PDF (158KB)
|
|
ISSN:0003-3022
出版商:OVID
年代:1980
数据来源: OVID
|
17. |
Hypoglycemia‐induced Seizures in an Infant during Anesthesia |
|
Anesthesiology,
Volume 52,
Issue 1,
1980,
Page 77-77
Aubrey Maze,
Stanley Samuels,
Preview
|
PDF (165KB)
|
|
摘要:
Ketamine hydrochloride is a popular drug for producing immobility during radiation therapy in young children. In certain patients methohexital sodium, 5 per cent, given by deep intramuscular injection has also proven to be a useful agent for this purpose. We present a case in which convulsions occurred following treatment with methohexital sodium.
ISSN:0003-3022
出版商:OVID
年代:1980
数据来源: OVID
|
18. |
V‐Lead Adapter |
|
Anesthesiology,
Volume 52,
Issue 1,
1980,
Page 78-79
Donald Sass,
Preview
|
PDF (252KB)
|
|
ISSN:0003-3022
出版商:OVID
年代:1980
数据来源: OVID
|
19. |
Pseudoaneurysrn, a Late Complication of Radial‐Artery Catheterization |
|
Anesthesiology,
Volume 52,
Issue 1,
1980,
Page 80-81
S. Wolf,
D. Mangano,
Preview
|
PDF (155KB)
|
|
摘要:
The most common complications of radial arterial catheterization are thrombus, embolus and hematoma formation,1–4usually detected prior to or shortly after decannulation. We report the uncommon occurrence of pseudoaneurysm formation 18 days after decannulation in a patient who had an otherwise uncomplicated hospital course.
ISSN:0003-3022
出版商:OVID
年代:1980
数据来源: OVID
|
20. |
Biochemical Alterations during Tetany |
|
Anesthesiology,
Volume 52,
Issue 1,
1980,
Page 82-82
L. Drop,
E. Miller,
Preview
|
PDF (148KB)
|
|
ISSN:0003-3022
出版商:OVID
年代:1980
数据来源: OVID
|
|