|
21. |
Immunoreactivity of Protamine Preparations Used to Reverse Heparin Anticoagulation |
|
Anesthesiology,
Volume 73,
Issue 2,
1990,
Page 328-331
Ursula Adourian,
Carol Hirshman,
N. Adkinson,
Michael Weiss,
Preview
|
PDF (326KB)
|
|
摘要:
To determine if four commercially available intravenous protamine preparations differed in their ability to bind to human anti-protamine antibody, the sera of seven protamine-insulin-dependent diabetics who had experienced life-threatening reactions to intravenous protamine and whose sera contained a mean of 67.4 μg/ml (range, 16–200 μg/ml) of antiprotamine IgG antibody were evaluated. Each serum was preincubated with buffer and 0.0014 to 1.4 mg/ml of the four protamine preparations before addition to an agarose-based solid-phase radioimmunoassay using125I-radiolabeled staph protein A as the detection protein. In the seven sera, the concentration of soluble protamine inhibiting 50% of protamine antibody (IC50) was determined by interpolating from points above and below 50% inhibition for each protamine preparation. No significant difference was found in the IC50among the four different protamine preparations (P> 0.25; Kruskal-Wallis). The authors concluded that there is no significant difference in the immunoreactivity of the four commercial protamine preparations with human antiprotamine IgG antibody. Thus, there appears to be no advantage in using a particular intravenous protamine preparation based on immunoreactivity with human antiprotamine antibody.
ISSN:0003-3022
出版商:OVID
年代:1990
数据来源: OVID
|
22. |
A Simple Pocket Calculator Approach to Predict Anesthetic Drug Concentrations from Pharmacokinetic Data |
|
Anesthesiology,
Volume 73,
Issue 2,
1990,
Page 332-336
Pierre Maitre,
Steven Shafer,
Preview
|
PDF (366KB)
|
|
摘要:
Use of pharmacokinetic concepts to predict anesthetic drug concentrations has not had extensive use in clinical anesthetic practice to date. The multiple exponent equations needed to describe iv drug disposition have required computer capability not practical for the operating room. An algorithm is presented that allows the clinician to use information from the pharmacokinetic literature to improve accuracy of drug dosing in the operating room. Implemented on a pocket calculator, this approach does not involve complex mathematics or lengthy computations and allows the clinician to obtain a continuous prediction of the plasma anesthetic concentration during the course of the anesthetic from iv bolus or continuous infusion of anesthetic drugs.
ISSN:0003-3022
出版商:OVID
年代:1990
数据来源: OVID
|
23. |
Anesthetic Management of Severely Hypokalemic Patients for Liver Transplantation |
|
Anesthesiology,
Volume 73,
Issue 2,
1990,
Page 337-339
Georges Khoury,
Scot Foster,
David Raybould,
Anthony Nyerges,
Ronald Busuttil,
Preview
|
PDF (317KB)
|
|
ISSN:0003-3022
出版商:OVID
年代:1990
数据来源: OVID
|
24. |
A New Technique for Replacing an Endobronchial Double‐Lumen Tube with an Endotracheal Single‐Lumen Tube |
|
Anesthesiology,
Volume 73,
Issue 2,
1990,
Page 340-341
John Gatell,
Samuel Barst,
Dawn Desiderio,
Anne Kolker,
Corey Scher,
Preview
|
PDF (195KB)
|
|
ISSN:0003-3022
出版商:OVID
年代:1990
数据来源: OVID
|
25. |
Left Atrial Air Embolism during Intraoperative Needle Biopsy of a Deep Pulmonary Lesion |
|
Anesthesiology,
Volume 73,
Issue 2,
1990,
Page 342-344
Eugene Worth,
Robert Burton,
Rodney Landreneau,
G. Eggers,
Jack Curtis,
Preview
|
PDF (351KB)
|
|
ISSN:0003-3022
出版商:OVID
年代:1990
数据来源: OVID
|
26. |
Life‐threatening Apnea Following Spinal Anesthesia in Former Premature Infants |
|
Anesthesiology,
Volume 73,
Issue 2,
1990,
Page 345-347
ROBIN COX,
GERALD GORESKY,
Preview
|
PDF (304KB)
|
|
ISSN:0003-3022
出版商:OVID
年代:1990
数据来源: OVID
|
27. |
Fiberoptically Guided Intubation in Children with Gangrenous Stomatitis (Noma) |
|
Anesthesiology,
Volume 73,
Issue 2,
1990,
Page 348-349
EDΩMER TASSONYI,
CATHERINE LEHMANN,
KEVIN GUNNING,
ETIENNE COQUOZ,
DENYS MONTANDON,
Preview
|
PDF (187KB)
|
|
ISSN:0003-3022
出版商:OVID
年代:1990
数据来源: OVID
|
28. |
Severe Burns from a Pulse Oximeter |
|
Anesthesiology,
Volume 73,
Issue 2,
1990,
Page 350-352
KENNETH MURPHY,
JEFFREY SECUNDA,
MARK ROCKOFF,
Preview
|
PDF (213KB)
|
|
ISSN:0003-3022
出版商:OVID
年代:1990
数据来源: OVID
|
29. |
Failure of the Agent‐Specific Filling Device |
|
Anesthesiology,
Volume 73,
Issue 2,
1990,
Page 353-354
ELAINE RIEGLE,
DAVID DESERTSPRING,
Preview
|
PDF (151KB)
|
|
ISSN:0003-3022
出版商:OVID
年代:1990
数据来源: OVID
|
30. |
Capnometer Readings at High Altitude |
|
Anesthesiology,
Volume 73,
Issue 2,
1990,
Page 354-355
MARK HILBERMAN,
Preview
|
PDF (133KB)
|
|
ISSN:0003-3022
出版商:OVID
年代:1990
数据来源: OVID
|
|