1. |
A TIME TO REFLECT |
|
Heat Transfer Engineering,
Volume 3,
Issue 1,
1981,
Page 5-5
G. F. Hewitt,
Preview
|
PDF (48KB)
|
|
ISSN:0145-7632
DOI:10.1080/01457638108939570
出版商:Taylor & Francis Group
年代:1981
数据来源: Taylor
|
2. |
On the Necessary Criteria for Stream-Symmetric Tubular Heat Exchanger Geometries |
|
Heat Transfer Engineering,
Volume 3,
Issue 1,
1981,
Page 19-22
KRISHNAP. SINGH,
Preview
|
PDF (169KB)
|
|
摘要:
The basic criteria are derived in determining whether the heat transfer relationship for a given heat exchanger geometry is invariant to the interchanging of shell-side and tube-side fluids. It is shown that the total heat duty, LMTD correction factor, and other indices of exchanger performance remain unchanged for a stream-symmetric exchanger when the two flow streams are switched, provided the overall heat transfer coefficient is not changed.
ISSN:0145-7632
DOI:10.1080/01457638108939571
出版商:Taylor & Francis Group
年代:1981
数据来源: Taylor
|
3. |
Influence of Fouling Biofilms on Heat Transfer |
|
Heat Transfer Engineering,
Volume 3,
Issue 1,
1981,
Page 23-37
W. G. CHARACKLIS,
M. J. NEVIMONS,
B. F. PICOLOGLOU,
Preview
|
PDF (615KB)
|
|
摘要:
In heat exchange equipment, fouling biofilm formation causes a significant energy loss by increasing heat transfer resistance. This paper describes experiments which quantify the influence of fouling biofilms on heat transfer resistance under controlled laboratory conditions. Experimental results compare well with a rather simple mathematical model employing friction factor, biofilm thickness, wall temperature, bulk temperature, and fluid properties as inputs. Limitations of the experimental apparatus and mathematical model are discussed
ISSN:0145-7632
DOI:10.1080/01457638108939572
出版商:Taylor & Francis Group
年代:1981
数据来源: Taylor
|
4. |
Heat Transfer Coefficients and Pressure Drops for Air Coolers with Different Numbers of Rows Under Induced and Forced Draft |
|
Heat Transfer Engineering,
Volume 3,
Issue 1,
1981,
Page 38-48
E. GIANOLIO,
F. CUTI,
Preview
|
PDF (403KB)
|
|
摘要:
Tests are described on a pilot plant simulating an air-cooled heat exchanger that can be operated in both the induced-draft and forced-draft modes. Heat transfer coefficients in the induced-draft mode were well correlated, for greater than six rows, by the Briggs and Young correlation; for smaller numbers of rows, a new correlation is presented. In the forced-draft mode, however, none of the literature correlations fit the data and two new correlations (for more than six rows and for less than six rows, respectively) are presented. Data were also obtained for pressure drop and these are compared with existing correlations. Two new pressure-drop correlations are presented for the forced-draft mode.
ISSN:0145-7632
DOI:10.1080/01457638108939573
出版商:Taylor & Francis Group
年代:1981
数据来源: Taylor
|
5. |
Multizone Condensers: Desuperheating, Condensing, Subcooling |
|
Heat Transfer Engineering,
Volume 3,
Issue 1,
1981,
Page 49-61
FRANKL. RUBIN,
Preview
|
PDF (695KB)
|
|
摘要:
This article examines the design of multizone condensers. It also marks the first published discussion of the existence of a “wet desuperheating zon” in every multizone condenser with a “dry desuperheating zone. ’Considered in this discussion are only single component vapors in shell-and-tube heat exchangers with single shell-side pass
ISSN:0145-7632
DOI:10.1080/01457638108939574
出版商:Taylor & Francis Group
年代:1981
数据来源: Taylor
|
6. |
A Review of: “Heat Transfer”, 3rd ed., by V. P. Isachenko, V. A. Osipova, and A. S. Sukomel Translated into English from the Russian by S. Semyonov Mir Publishers, Moscow, 1981, 493 pages, $13.00 |
|
Heat Transfer Engineering,
Volume 3,
Issue 1,
1981,
Page 61-62
JamesP. Hartnett,
Preview
|
PDF (141KB)
|
|
ISSN:0145-7632
DOI:10.1080/01457638108939575
出版商:Taylor & Francis Group
年代:1981
数据来源: Taylor
|
|