1. |
How to Avoid Pitfalls of Tap Monitoring for Lead |
|
Opflow,
Volume 18,
Issue 8,
1992,
Page 1-7
William G. Richards,
Preview
|
PDF (268KB)
|
|
摘要:
The Lead and Copper Rule has many requirements. This article focuses on the initial monitoring requirements for lead using tap samples, and on many of the practical difficulties in complying with them. Special attention is paid to the issue of residents or customers sampling their own water for use by the utility.
ISSN:0149-8029
DOI:10.1002/j.1551-8701.1992.tb00303.x
出版商:Wiley
年代:1992
数据来源: WILEY
|
2. |
Biofilm Problems Make It Difficult to Comply With SDWA |
|
Opflow,
Volume 18,
Issue 8,
1992,
Page 3-3
Trudie Lay,
Preview
|
PDF (85KB)
|
|
摘要:
Biological regrowth (BRG) is another name for an increase in live microorganisms in drinking water after disinfection has been completed. The microorganisms, which include coliform bacteria, other bacteria, fungi, or yeasts, may become suspended in the water or attach to the walls of the distribution system, forming what is known as “biofilm.” Biofilm can trigger positive test results for things such as E. coli. The article discusses: the importance of BRG prevention; total coliform rule; surface water treatment rule; BRG research; and solving BRG problems.
ISSN:0149-8029
DOI:10.1002/j.1551-8701.1992.tb00300.x
出版商:Wiley
年代:1992
数据来源: WILEY
|
3. |
USEPA Approves New Method for Total Coliform Testing |
|
Opflow,
Volume 18,
Issue 8,
1992,
Page 4-4
Preview
|
PDF (755KB)
|
|
摘要:
This article describes Colilert, a quick and easy way to test for coliforms. Other similar tests, such as Coliquick and Colisure, perform the same function but at the time this article was printed, were still awaiting final USEPA approval.
ISSN:0149-8029
DOI:10.1002/j.1551-8701.1992.tb00301.x
出版商:Wiley
年代:1992
数据来源: WILEY
|
4. |
Water Quality Data Only as Good as the Sample |
|
Opflow,
Volume 18,
Issue 8,
1992,
Page 5-8
Eugenia Carey,
Preview
|
PDF (191KB)
|
|
摘要:
This article highlights the fundamental parts of a sampling program, including designing the program, taking the sample, and labeling, preserving, and transporting the sample. Employee training is also covered, with specific suggestions for what employees should be taught.
ISSN:0149-8029
DOI:10.1002/j.1551-8701.1992.tb00302.x
出版商:Wiley
年代:1992
数据来源: WILEY
|
5. |
Contest Winners Clinch Awards in Tight Race |
|
Opflow,
Volume 18,
Issue 8,
1992,
Page 9-10
Preview
|
PDF (1167KB)
|
|
摘要:
The cam‐lock valve can remover makes removing or adjusting valve cans easier by eliminating the need for multiple tools. The device allows the operator to use proper posture, and reduces the risk of busted knuckles. This article tells how the can remover works and gives instructions and drawings for construction.
ISSN:0149-8029
DOI:10.1002/j.1551-8701.1992.tb00304.x
出版商:Wiley
年代:1992
数据来源: WILEY
|
|