1. |
Brine Well Provides Salt Needed for Softening |
|
Opflow,
Volume 10,
Issue 1,
1984,
Page 1-1
Lawrence Valentine,
Preview
|
PDF (66KB)
|
|
摘要:
In 1966, the City of Cuyahoga Falls, Ohio, whose water treatment plant has an average capacity of 6 mgd, used approximately 10 mil lb (4.5 mil kg) of salt, costing $45,000, to regenerate synthetic zeolite for water softening. This article describes the drilling and development of a brine well to be used as a source of the needed salt solution. Technical aspects and development costs of the brine treatment unit are detailed. At current production and use rates, the salt well represents an annual savings of $234,000 per year.
ISSN:0149-8029
DOI:10.1002/j.1551-8701.1984.tb00143.x
出版商:Wiley
年代:1984
数据来源: WILEY
|
2. |
A Little Hole Can Lose “Alot” of Water |
|
Opflow,
Volume 10,
Issue 1,
1984,
Page 2-2
Preview
|
PDF (77KB)
|
|
摘要:
This table presents data on the amounts of water that will be lost on a quarterly basis through various size holes at 60 lb of pressure.
ISSN:0149-8029
DOI:10.1002/j.1551-8701.1984.tb00144.x
出版商:Wiley
年代:1984
数据来源: WILEY
|
3. |
Certification Corner |
|
Opflow,
Volume 10,
Issue 1,
1984,
Page 3-8
Preview
|
PDF (762KB)
|
|
摘要:
This month's “Certification Corner” presents questions on the following topics: flume delivery capacity; motor energy use; calcium hypochlorite and sodium hypochlorite solutions; the multiple‐tube test; preventive maintenance; centrifugal pumps; and reduced‐pressure principle backflow prevention device installation.
ISSN:0149-8029
DOI:10.1002/j.1551-8701.1984.tb00146.x
出版商:Wiley
年代:1984
数据来源: WILEY
|
4. |
Selecting Instruments in Small Treatment Plants |
|
Opflow,
Volume 10,
Issue 1,
1984,
Page 4-5
Terry L. Engelhardt,
Preview
|
PDF (1799KB)
|
|
摘要:
The instruments used in every water treatment plant fall into two broad categories: laboratory instruments and process monitoring and/or control instruments. Basic laboratory instruments that nearly every water treatment plant should consider are discussed, including: turbidimeters; pH meters; jar test apparatus; colorimeters; online process‐control instruments; microscopes; and balances. The selection process should consider location, intended use, availability of prepackaged reagents, required degree of precision and accuracy, accessories, and an economical method of analysis in compliance with regulatory agencies.
ISSN:0149-8029
DOI:10.1002/j.1551-8701.1984.tb00147.x
出版商:Wiley
年代:1984
数据来源: WILEY
|
5. |
Arc Welder Used to Thaw Frozen Pipes |
|
Opflow,
Volume 10,
Issue 1,
1984,
Page 6-7
LaVern M. Nelson,
Preview
|
PDF (795KB)
|
|
摘要:
This paper describes the use of gasoline‐powered DC arc welders, rated at at least 450 A continuous duty, for thawing of frozen pipes in Madison, Wisconsin during the winter of 1976‐1977. Equipment, procedures, and time factors are discussed, and the need for proper training and safety practices is emphasized.
ISSN:0149-8029
DOI:10.1002/j.1551-8701.1984.tb00148.x
出版商:Wiley
年代:1984
数据来源: WILEY
|
6. |
Tank Leg Splits from Water Buildup |
|
Opflow,
Volume 10,
Issue 1,
1984,
Page 7-7
Kenneth Farnsworth,
Preview
|
PDF (94KB)
|
|
摘要:
On January 7, 1979, one of the legs on an elevated water storage tank containing 150,000 gallons (568,000 L) of water split due to ice buildup in the bottom section. This paper describes the action taken by utility officials in Wellington, Ohio to repair the split and prevent a similar occurrence at the town's other storage tank.
ISSN:0149-8029
DOI:10.1002/j.1551-8701.1984.tb00149.x
出版商:Wiley
年代:1984
数据来源: WILEY
|
|