1. |
Plant operations shorts |
|
Plant/Operations Progress,
Volume 6,
Issue 4,
1987,
Page 5-5
Preview
|
PDF (112KB)
|
|
ISSN:0278-4513
DOI:10.1002/prsb.720060402
出版商:American Institute of Chemical Engineers
年代:1987
数据来源: WILEY
|
2. |
Comments on “Hazard analysis and safety consideration in refrigerated ammonia storage tanks” by Falah Al‐Abdulally, Saad Al‐Shuwaib and B. L. Gupta |
|
Plant/Operations Progress,
Volume 6,
Issue 4,
1987,
Page 6-8
Jan M. Blanken,
Preview
|
PDF (191KB)
|
|
ISSN:0278-4513
DOI:10.1002/prsb.720060403
出版商:American Institute of Chemical Engineers
年代:1987
数据来源: WILEY
|
3. |
Conclusions of industry task group on nitrogen oxides in ethylene plants |
|
Plant/Operations Progress,
Volume 6,
Issue 4,
1987,
Page 9-11
Fred C. Politz,
Preview
|
PDF (276KB)
|
|
ISSN:0278-4513
DOI:10.1002/prsb.720060404
出版商:American Institute of Chemical Engineers
年代:1987
数据来源: WILEY
|
4. |
Safety and health division news |
|
Plant/Operations Progress,
Volume 6,
Issue 4,
1987,
Page 13-13
Preview
|
PDF (113KB)
|
|
ISSN:0278-4513
DOI:10.1002/prsb.720060416
出版商:American Institute of Chemical Engineers
年代:1987
数据来源: WILEY
|
5. |
Flame barrier valves |
|
Plant/Operations Progress,
Volume 6,
Issue 4,
1987,
Page 175-180
Hans Stalder,
Preview
|
PDF (821KB)
|
|
摘要:
AbstractApplication of quick closing valves for separating of plant parts and for section‐like protection of pipe lines in case of dust explosion
ISSN:0278-4513
DOI:10.1002/prsb.720060405
出版商:American Institute of Chemical Engineers
年代:1987
数据来源: WILEY
|
6. |
Understanding cooling towers: The route to energy savings |
|
Plant/Operations Progress,
Volume 6,
Issue 4,
1987,
Page 181-184
Matt Smith,
Preview
|
PDF (418KB)
|
|
摘要:
AbstractWhy do we use cooling towers? The answer is simple. Cooling towers allow us to efficiently reject heat to the atmosphere at a lower temperature than other available processes. The key words in that last sentence are “at a lower temperature
ISSN:0278-4513
DOI:10.1002/prsb.720060406
出版商:American Institute of Chemical Engineers
年代:1987
数据来源: WILEY
|
7. |
Environmental compliance without sacrificing customer requirements |
|
Plant/Operations Progress,
Volume 6,
Issue 4,
1987,
Page 185-187
Roberta I. Pollard‐Cavalli,
Preview
|
PDF (366KB)
|
|
摘要:
AbstractReformulation of paraformaldehyde has reduced exposure while improving product properties. Solvent substitution and process modification in product lines have resulted in reduction of benzene emissions and more favorable product specifications.
ISSN:0278-4513
DOI:10.1002/prsb.720060407
出版商:American Institute of Chemical Engineers
年代:1987
数据来源: WILEY
|
8. |
Inhibitor‐oxygen interactions in acrylic acid stabilization |
|
Plant/Operations Progress,
Volume 6,
Issue 4,
1987,
Page 188-189
Leon B. Levy,
Preview
|
PDF (268KB)
|
|
摘要:
AbstractPolymerization inhibitors are used in the processing and storage of acrylic acid. Depending upon the inhibitor and the conditions, it is sometimes imperative that oxygen be present for inhibitor “activation
ISSN:0278-4513
DOI:10.1002/prsb.720060408
出版商:American Institute of Chemical Engineers
年代:1987
数据来源: WILEY
|
9. |
Gas plant problems and the insurance industry |
|
Plant/Operations Progress,
Volume 6,
Issue 4,
1987,
Page 190-192
Arthur Spiegelman,
Preview
|
PDF (357KB)
|
|
摘要:
AbstractThe methodology used by insurance companies in evaluating risk covers both property and casualty insurance. Topics of discussion include: Total Loss Control (How to achieve it, and its relationship to Governmental Regulations), and the importance of equipment design and maintenance in preventing catastrophic losses. This discussion is based on studies of hundreds of large losses over the past twenty‐five year
ISSN:0278-4513
DOI:10.1002/prsb.720060409
出版商:American Institute of Chemical Engineers
年代:1987
数据来源: WILEY
|
10. |
Effect of fireproofing design on thermal performance of horizontal members with top flange exposed |
|
Plant/Operations Progress,
Volume 6,
Issue 4,
1987,
Page 193-198
G. K. Castle,
G. G. Castle,
Preview
|
PDF (542KB)
|
|
摘要:
AbstractIt is common practice in the industrial sector to leave the top flanges of fireproofed beams bare. The main reason for this is to permit placement of pipes and grating on the beams without interference from fireproofing materials. To the authors' knowledge, tests of such configurations have not been conducted to determine actual resistance to fire. However, structures fireproofed in this manner have survived actual fire exposures. The purpose of this paper is to examine theoretically the effect of various fireproofing designs on the performance of these members and point out which practices can lead to premature failure of fireproofed beams where top surfaces are left bare. An approximate but practical analytical model is used to evaluate bare steel, encased (concrete/contour) and box (hollow) constructions. The need for reinforcements is demonstrated by examining the effect of bond loss in decomposable systems. Thermal performance is related to load carrying capability of the member.
ISSN:0278-4513
DOI:10.1002/prsb.720060410
出版商:American Institute of Chemical Engineers
年代:1987
数据来源: WILEY
|