|
21. |
Fine‐needle aspiration of the breast: A review of 1,995 cases with emphasis on diagnostic pitfalls |
|
Diagnostic Cytopathology,
Volume 9,
Issue 1,
1993,
Page 106-112
Nour Sneige,
Preview
|
PDF (2641KB)
|
|
摘要:
AbstractBetween 1985 to 1989, 1, 95 fine‐needle aspirations of palpable breast lesions were performed at our institution. In all cases, the aspirates were procured by cytopathologists using 22‐ or 23‐gauge needles. Direct smears were immediately stained with Diff‐Quik and Papanicolaou and assessed for specimen adequacy (criteria as followed in this institution). Tissue follow‐up was available in 1,117 cases. The cytologic diagnoses rendered in these cases were: malignant, 690 cases (60.2%); suspicious for carcinoma, 49 cases (4.3%); benign, 343 cases (29.9%), and insufficient specimen, 35 cases (3.1%). There were 28 false‐negative and 2 false‐positive results. Considering only cases definitively diagnosed as benign or malignant, the sensitivity was 96%, specificity 99%, positive predictive value 99%, negative predictive value 94%, and overall efficiency 97%. Of those specimens considered suspicious, only 11 cases (22%) were proved not to be malignant after excisional biopsy. These were three fibroadenomas, three ductal hyperplasias, two adenosis tumors, two mucocele‐like lesions, and one nipple adenoma. The two lesions that resulted in true false‐positive diagnoses were an apocrine cyst with atypia and sclerosing adenosis with radial scar. The clinical and cytologic features of the benign conditions that resulted in false suspicious and positive diagnoses and those features that distinguish them from carcin
ISSN:8755-1039
DOI:10.1002/dc.2840090122
出版商:Wiley Subscription Services, Inc., A Wiley Company
年代:1993
数据来源: WILEY
|
22. |
Cytobrush sampling in conjunctival cytology |
|
Diagnostic Cytopathology,
Volume 9,
Issue 1,
1993,
Page 113-115
Irene Anagnostopoulou‐Fotinopoulou,
Rea Rammou‐Kinia,
Preview
|
PDF (897KB)
|
|
摘要:
AbstractThe cervical cytobrush was used to obtain samples from the temporal bulbar conjunctiva of normal and nonnormal eyes in 54 cases after application of local anesthesia. The cotton swab was also used. All samples were smeared on glass slides, fixed immediately and then stained by a routine Papanicolaou method. On microscopic examination plenty of well preserved cells were present in all smears sampled by the cervical cytobrush. On the contrary, all samples obtained by the cotton swab contained few cells, most of which showed degeneration. The cervical cytobrush is very useful to conjunctival cytology because it provides abundant cellular material and good cell preservation, using standard and simple preparatory methods.
ISSN:8755-1039
DOI:10.1002/dc.2840090123
出版商:Wiley Subscription Services, Inc., A Wiley Company
年代:1993
数据来源: WILEY
|
23. |
Comprehensive cytopathology Editor: M. Bibbo, W.B. Saunders, Philadelphia, 1992 |
|
Diagnostic Cytopathology,
Volume 9,
Issue 1,
1993,
Page 116-116
Patricia A. Thomas,
Preview
|
PDF (74KB)
|
|
ISSN:8755-1039
DOI:10.1002/dc.2840090124
出版商:Wiley Subscription Services, Inc., A Wiley Company
年代:1993
数据来源: WILEY
|
24. |
Abstract digest |
|
Diagnostic Cytopathology,
Volume 9,
Issue 1,
1993,
Page 117-122
Preview
|
PDF (601KB)
|
|
ISSN:8755-1039
DOI:10.1002/dc.2840090125
出版商:Wiley Subscription Services, Inc., A Wiley Company
年代:1993
数据来源: WILEY
|
25. |
Reaction to the new asc poster session format |
|
Diagnostic Cytopathology,
Volume 9,
Issue 1,
1993,
Page 123-123
Sonya Naryshkin,
Preview
|
PDF (98KB)
|
|
ISSN:8755-1039
DOI:10.1002/dc.2840090126
出版商:Wiley Subscription Services, Inc., A Wiley Company
年代:1993
数据来源: WILEY
|
26. |
Forthcoming events |
|
Diagnostic Cytopathology,
Volume 9,
Issue 1,
1993,
Page 124-125
Preview
|
PDF (121KB)
|
|
ISSN:8755-1039
DOI:10.1002/dc.2840090127
出版商:Wiley Subscription Services, Inc., A Wiley Company
年代:1993
数据来源: WILEY
|
27. |
Masthead |
|
Diagnostic Cytopathology,
Volume 9,
Issue 1,
1993,
Page -
Preview
|
PDF (56KB)
|
|
ISSN:8755-1039
DOI:10.1002/dc.2840090101
出版商:Wiley Subscription Services, Inc., A Wiley Company
年代:1993
数据来源: WILEY
|
|