11. |
Chemiluminescent Analyte Microdetection Based on the Luminol-H2O2Reaction Using Peroxidase Immobilized on New Synthetic Membranes |
|
Analytical Letters,
Volume 20,
Issue 2,
1987,
Page 317-326
L.J. Blum,
J.M. Plaza,
P.R. Coulet,
Preview
|
PDF (419KB)
|
|
摘要:
Horse radish peroxidase, involved in enzyme-mediated luminol chemiluminescence, was immobilized on new polyamide membranes supplied in a preactivated form. In the presence of 1 × 10−4M luminol, H2O2can be detected between 1 × 10−8M and 1 × 10−4M by measuring the maximum intensity of light emitted. The use of soluble cholesterol oxidase (COD) as model enzyme, allowed a chemiluminescent determination of cholesterol. A compromise between the conditions for both enzymes activity expression, a sufficient light emission and a low background luminescence was accepted in the choice of the pH of assays fixed at 8. The chemiluminescent signal integrated during 150 sec was linear with cholesterol in the range 2.5 × 10−8M - 2.5 × 10−5M. With maximum light intensity measurements, a linear calibration graph was obtained from 1 × 10−8M to 2.5 × 10−4M but with a response-time depending on the measured concentration.
ISSN:0003-2719
DOI:10.1080/00032718708064568
出版商:Taylor & Francis Group
年代:1987
数据来源: Taylor
|
12. |
Response Model for Chemoreceptor Biosensors |
|
Analytical Letters,
Volume 20,
Issue 2,
1987,
Page 327-336
S.L. Belli,
R.M. Buch,
G.A. Rechnitz,
Preview
|
PDF (251KB)
|
|
摘要:
A model is proposed to explain the overall dynamic response range of intact chemoreceptor structures, by postulating an array of chemoreceptive cells with limited individual dynamic ranges. The model contends that the sensitivity ranges of chemoreceptive cells are governed by the extent of dendritic branching and predicts a population of chemoreceptive cells with differing sensitivity ranges. The rapid response time of biosensors incorporating intact chemosensory structures is also explained.
ISSN:0003-2719
DOI:10.1080/00032718708064569
出版商:Taylor & Francis Group
年代:1987
数据来源: Taylor
|
13. |
Fluorometric Cell Detection Method Using Complement-Mediated Cytolytic Reaction and Imaging Sensor System |
|
Analytical Letters,
Volume 20,
Issue 2,
1987,
Page 337-348
Masayasu Suzuki,
Eiichi Tamiya,
Isao Karube,
Tetsuro Kataoka,
Tohru Tokunaga,
Preview
|
PDF (307KB)
|
|
摘要:
A rapid and sensitive cell detection method using complement-mediated cytolytic reaction and an image processing system was developed. The present system consists of SIT video camera, fluorescent microscope and personal computer system equipped with image memory board.
ISSN:0003-2719
DOI:10.1080/00032718708064570
出版商:Taylor & Francis Group
年代:1987
数据来源: Taylor
|
14. |
Spectrophotometric Analysis of Diclofenac Sodium and Piroxicam and Their Pharmaceutical Preparations |
|
Analytical Letters,
Volume 20,
Issue 2,
1987,
Page 349-359
Suryaprakasa Sastry,
A.Rama Mohana Rao,
T.N. V. Prasad,
Preview
|
PDF (312KB)
|
|
摘要:
Simple spectrophotometric methods for the determination of diclofenac sodium and piroxicam in bulk samples and pharmaceutical preparations, based on the formation of colored species with 3-methyl-2-benzothiazolinone hydra-zone hydrochloride - Ce+ 4, are presented. The methods are simple, sensitive, rapid and accurate. The results obtained are reproducible with a coefficient of variation less than 2%.
ISSN:0003-2719
DOI:10.1080/00032718708064571
出版商:Taylor & Francis Group
年代:1987
数据来源: Taylor
|
15. |
Editorial board page for “Analytical Letters”, Volume 20, Number 2 |
|
Analytical Letters,
Volume 20,
Issue 2,
1987,
Page -
Preview
|
PDF (101KB)
|
|
摘要:
This is a scanned image of the original Editorial Board page(s) for this issue.
ISSN:0003-2719
DOI:10.1080/00032718708064557
出版商:Taylor & Francis Group
年代:1987
数据来源: Taylor
|
|