1. |
Micro High Performance Liquid Chromatography of Organically Bound Metals with Inductively Coupled Plasma Atomic Emission Spectrometric Detection |
|
Analytical Letters,
Volume 15,
Issue 5,
1982,
Page 427-437
Kiyokatsu Jinno,
Hiroyuki Tsuchida,
Preview
|
PDF (310KB)
|
|
摘要:
The combination technique of micro high performance liquid chromatography and inductively coupled plasma atomic emission spectrometry is demonstrated in the separation of organometallic compounds. Problems relating to the interfacing between micro HPLC and ICP would be elininated uti1izing the simple interfacing technique.
ISSN:0003-2719
DOI:10.1080/00032718208069494
出版商:Taylor & Francis Group
年代:1982
数据来源: Taylor
|
2. |
Determination of Polynuclear Aromatic Hydrocarbons by a Spiked Mobile Phase Fluorescence Hplc Detector |
|
Analytical Letters,
Volume 15,
Issue 5,
1982,
Page 439-450
SyangY. Su,
E.P. C. Lai,
J.D. Winefordner,
Preview
|
PDF (336KB)
|
|
摘要:
The negative peak fluorescent detector previously described in this journal by Su and Winefordner1is used now to determine both fluorescent and non-fluorescent polynuclear aromatic hydrocarbons (PAH's). Here we report on limits of detecticn, linear dynamic ranges, calibration curve slopes and chromatographic retention times for several PAH's. We also report on the effect of solvent polarity upon the fluorescence signals when an HPLC separation is performed using a reversed phase packing and a polar solvent containing a fluorescent tag. The negative peak fluorescent detector is also shown to be useful in solvent programming studies.
ISSN:0003-2719
DOI:10.1080/00032718208069495
出版商:Taylor & Francis Group
年代:1982
数据来源: Taylor
|
3. |
Chromatographic Separation of Some Antihistamines on Silica Gel-Metal Salt Impregnated Thin Lyer Plate |
|
Analytical Letters,
Volume 15,
Issue 5,
1982,
Page 451-457
S.P. Srivastava,
Reena,
Preview
|
PDF (194KB)
|
|
摘要:
A scheme for the TLC separation of seven Antihistamines on silica gel metal salt impregnated plates by using a mixture of Ethanol-DMF-ammonia (32:10:0.2) as developing system and employing Dragendroff reagent as visualization reagent is described.
ISSN:0003-2719
DOI:10.1080/00032718208069496
出版商:Taylor & Francis Group
年代:1982
数据来源: Taylor
|
4. |
Structure de Modeles de Polyesters 2.-Determination de la Purete optique par RMN13C et H de Dibenzoyloxy 1,2 Propane, l,3 Butane et 3-Methyl 1,4 Butane a l'Aide de Reactifs chiraux |
|
Analytical Letters,
Volume 15,
Issue 5,
1982,
Page 459-469
Marie-Florence Grenier-loustalot,
Preview
|
PDF (264KB)
|
|
摘要:
The enantiomeric purity of a series of polyester model compounds has been assayed by NMR spectroscopy, using chiral lantha-nide shift reagents. The dependencc of proton and13C NMR spectra on concentration and temperature has been investigated.
ISSN:0003-2719
DOI:10.1080/00032718208069497
出版商:Taylor & Francis Group
年代:1982
数据来源: Taylor
|
5. |
Identification and Determination of Lsd in Illicit Preparations Using Synchronous Spectro Fluorimetry |
|
Analytical Letters,
Volume 15,
Issue 5,
1982,
Page 471-492
Ph. Baudot,
J.C. André,
Preview
|
PDF (595KB)
|
|
摘要:
Molecular fluorescence is much in use nowadays as an analytical technique, particularly for the determination of traces of toxic fluorescent substances. The authors describe a spectrofluorimetric method, called the synchronous excitation method, which is more sensitive and more selective than the classical spectrofluorimetry and which can be used for the direct determination, in the presence of other hallucinogens, of LSD in confiscated samples. They also propose the application, under certain conditions, of the method as a rapid test for the presence of LSD.
ISSN:0003-2719
DOI:10.1080/00032718208069498
出版商:Taylor & Francis Group
年代:1982
数据来源: Taylor
|
6. |
An Improved Method for the Determination of Molybdenum in Plants, Soils, and Rocks |
|
Analytical Letters,
Volume 15,
Issue 5,
1982,
Page 493-505
A.B. Carel,
J.W. Wimberley,
Preview
|
PDF (345KB)
|
|
摘要:
Improvements to the thiocyanate colorimetric procedure for analysis of ppm levels of molybdenum have been made. The complete procedure was studied and revisions made to the solvent extraction system to increase sensitivity. The solvent itself was stabilized by elution through an adsorption column. Revisions to the fusion procedure were made to eliminate hand fusion of samples. The use of desiceants for solvent drying was replaced by filtration before absorbance readings to eliminate turbidity. Total solution of rock samples requires a special digestion procedure with atomic absorption finish.
ISSN:0003-2719
DOI:10.1080/00032718208069499
出版商:Taylor & Francis Group
年代:1982
数据来源: Taylor
|
7. |
The Limit of Detection of a Weak Acid, in the Presence of Another, by Potentiometric Acid-Base Titrimetry and Deviation-Pattern Recognition |
|
Analytical Letters,
Volume 15,
Issue 5,
1982,
Page 507-517
Louis Meites,
Preview
|
PDF (297KB)
|
|
摘要:
When a solution containing a single monobasic weak acid is titrated potentiometrically with a strong base, non-linear regression analysis of the data yields a random scatter of the residuals around the best fit to the appropriate equation. If the same equation is used when a second weak acid is also present, systematic errors arise and yield a deviation plot having a characteristic shape. If the amplitude of that plot is substantially larger than the random error of measurement, the presence of the second acid can be detected, and its concentration can then be evaluated by non-linear regression onto the equation that takes its presence into account. The amplitude increases as the relative concentration of the second acid increases, and as the difference between the values of pKafor the two acids increases. Examination of these dependences shows, for example, that it should be possible to detect 1 per cent of an impurity for which pKadiffers by 0.57 unit from that of the major component.
ISSN:0003-2719
DOI:10.1080/00032718208069500
出版商:Taylor & Francis Group
年代:1982
数据来源: Taylor
|
8. |
Editorial board page for “Analytical Letters”, Volume 15, Number 5 |
|
Analytical Letters,
Volume 15,
Issue 5,
1982,
Page -
Preview
|
PDF (71KB)
|
|
摘要:
This is a scanned image of the original Editorial Board page(s) for this issue.
ISSN:0003-2719
DOI:10.1080/00032718208069493
出版商:Taylor & Francis Group
年代:1982
数据来源: Taylor
|