1. |
Use of the Rotated Ring Disc Electrode for the Analytical Determination of Dithiaalcanediols in Aquo-Alcoholic Media and Its Rate of Oxidation with Bromine |
|
Analytical Letters,
Volume 12,
Issue 14,
1979,
Page 1411-1422
E.G. Sement,
J. Moiroux,
Preview
|
PDF (270KB)
|
|
摘要:
We used bromine generated and detected on the ring-dise electrode for the titration of aquo-alcoholic solution of dithiaalcanediol. The analysis of the ring currentvsdisc current curve provided a means of determination of the rate constantkof the second order homogeneous and fast reaction of bromine with each of the two sulfide groups of dithiaalcanediol. A value of (3+1)× 10−6M−1s−1was found forkat 25°C.
ISSN:0003-2719
DOI:10.1080/00032717908082542
出版商:Taylor & Francis Group
年代:1979
数据来源: Taylor
|
2. |
Determination of Caffeine in Small Plasma Samples by Gas-Liquid Chromatography with Thin-Layer Chromatographic Sample Clean-Up |
|
Analytical Letters,
Volume 12,
Issue 14,
1979,
Page 1423-1433
Abram Hulshoff,
Preview
|
PDF (293KB)
|
|
摘要:
A sensitive method for the determination of caffeine in small plasma samples (50 μ1) is described. The samples are extracted with chloroform and the extrects are freed from interfering compounds by thin-layer chronatography. The spots of caffeine and the internal standard, 7-ethyl theophylline, are scraped off the plates and both compounds are eluted from the scrapings by means of a glass capillary collector. The caffeine in the eluate is quantitated by gas-
ISSN:0003-2719
DOI:10.1080/00032717908082543
出版商:Taylor & Francis Group
年代:1979
数据来源: Taylor
|
3. |
Determination of Promethazine in Biological Fluids |
|
Analytical Letters,
Volume 12,
Issue 14,
1979,
Page 1435-1442
G. Taylor,
R.T. Calvert,
J.B. Houston,
Preview
|
PDF (194KB)
|
|
摘要:
A procedure for the determination of promethazine in plasma and urine has been developed which involves solvent extraction and gas chromatography using an alkaline flame ionisation detector. This procedure is sensitive and reproducible and can be applied to samples from humans receiving therapeutic doses of promethazine.
ISSN:0003-2719
DOI:10.1080/00032717908082544
出版商:Taylor & Francis Group
年代:1979
数据来源: Taylor
|
4. |
An Improved Method to Assay Folates in Milk by a Turbidimetric Microbiological Assay |
|
Analytical Letters,
Volume 12,
Issue 14,
1979,
Page 1443-1449
JackM. Cooperman,
Nobuhiro Shimizu,
Preview
|
PDF (210KB)
|
|
摘要:
Folates in milk are heat labile and methods used to protect these folates during sample preparation for microbiological estimation of this vitamin result in opaque solutions unsuitable for turbidimetric assays. This has necessitated the use of titrimetric assay for milk folates which are long and cumbersome. By the use of rennin precipitation of casein under conditions which preserve the folate activity, an optically clear solution is obtained which can then be used for turbidimetric assay. This method is described in this paper.
ISSN:0003-2719
DOI:10.1080/00032717908082545
出版商:Taylor & Francis Group
年代:1979
数据来源: Taylor
|
5. |
Determination of Calcium and Magnesium in Cardiac and Skeletal Muscle by Atomic Absorption Spectroscopy Using Stoichiometric Nitrous Oxide-Acetylene Flame |
|
Analytical Letters,
Volume 12,
Issue 14,
1979,
Page 1451-1475
SyamalK. Bhattacharya,
JamesC. Williams,
GenaroM.A. Palmieri,
Preview
|
PDF (681KB)
|
|
摘要:
A highly sensitive technique is reported for the determination of calcium and magnesium contents in demoisturized, defatted and
ISSN:0003-2719
DOI:10.1080/00032717908082546
出版商:Taylor & Francis Group
年代:1979
数据来源: Taylor
|
6. |
Enzyme Electrode with Collagen-Immobilized Cholesterol Oxidase for the Microdetermination of Free Cholesterol |
|
Analytical Letters,
Volume 12,
Issue 14,
1979,
Page 1477-1488
Catherine Bertrand,
PierreR. Coulet,
DanièleC. Gautheron,
Preview
|
PDF (363KB)
|
|
摘要:
Cholesterol oxidase has been immobililzed on collagen films associated to an electrochemical sensor to form a “cholesterol electrode”. The electrode poised at a potential of + 650 my vs Ag/AgCl detects the hydrogen peroxide produced in the enzymatic reaction. This device presents a very high sensitivity and a wide range of linearity (10−7M - 0.8.10−4M). The use of a non enzymatic electrode associated with the enzymatic one allowed the detection and correction of electrochemical interferences when applied to human sera for free cholesterol determination.
ISSN:0003-2719
DOI:10.1080/00032717908082547
出版商:Taylor & Francis Group
年代:1979
数据来源: Taylor
|
7. |
Determination of Atmospheric Halocarbon Concentrations by Gas Chromatography-Mass Spectrometry |
|
Analytical Letters,
Volume 12,
Issue 14,
1979,
Page 1489-1496
D.R. Cronn,
D.E. Harsch,
Preview
|
PDF (221KB)
|
|
摘要:
GC-MS methods have been developed which provide either analysis of eleven halocarbons in ambient air samples or only rapid analyses of CH3CI and CH2CI2, two species for which GC-ECD is particularly insensitive. Detection limits and precision of analysis for the remaining species are generally not as good as with GC-ECD, but the methods provide separate checks for more certain identification of the particular species of interest. In addition, the methods exhibit more uniform sensitivity for all of the halocarbons, and the GC oven can be temperature-
ISSN:0003-2719
DOI:10.1080/00032717908082548
出版商:Taylor & Francis Group
年代:1979
数据来源: Taylor
|
8. |
Editorial board page for “Analytical Letters”, Volume 12, Number 14 |
|
Analytical Letters,
Volume 12,
Issue 14,
1979,
Page -
Preview
|
PDF (94KB)
|
|
摘要:
This is a scanned image of the original Editorial Board page(s) for this issue.
ISSN:0003-2719
DOI:10.1080/00032717908082541
出版商:Taylor & Francis Group
年代:1979
数据来源: Taylor
|