1. |
Computer-Controlled Variable Sweep Rate Voltammetry |
|
Analytical Letters,
Volume 14,
Issue 7,
1981,
Page 463-478
R.M.A. Von Wandruszka,
M. Maraschin,
Preview
|
PDF (424KB)
|
|
摘要:
A microcomputer was interfaced to a potentiostat, providing a fully automated system for linear-sweep and cyclic voltammetry. it was used for metal-ion analysis, by the determination of peak currents in a series of applied potential sweeps of increasing sweep rates. The slopes of the plots of peak current vs square root of sweep rate were calculated and related to the concentrationsvialinear equations. Carbon-paste electrodes were used and the equations for various electroactive species were found to be analytically applicable with newly prepared electrodes.
ISSN:0003-2719
DOI:10.1080/00032718108081421
出版商:Taylor & Francis Group
年代:1981
数据来源: Taylor
|
2. |
The Effect of the Inner Solution of the Valinomycin-based Potassium Electrode on the Calibration Curve, Selectivity Coefficients and the Anion Interference |
|
Analytical Letters,
Volume 14,
Issue 7,
1981,
Page 479-491
Liisa Jalkanen,
Rauno Virtanen,
Preview
|
PDF (345KB)
|
|
摘要:
The effect of the inner solution on the potential in neutral carrier electrodes is considered constant in theoretical discussions. Because simplifying assumptions are made when deriving the potential equation, the purpose of this study has been to find out whether the measuring range of a valinomycin potassium electrode could be extended by changing the activity of the inner reference solution. The measurements show that changing the concentration of the inner solution in the range 10−5M - 0.1 M(1 M for calibration) does not affect the calibration curve, selectivity or the anion interference.
ISSN:0003-2719
DOI:10.1080/00032718108081422
出版商:Taylor & Francis Group
年代:1981
数据来源: Taylor
|
3. |
Fluoride Determination in Water: An Optimum Buffer System for Use with the Flouride-Selective Electrode |
|
Analytical Letters,
Volume 14,
Issue 7,
1981,
Page 493-517
K. Nicholson,
E.J. Duff,
Preview
|
PDF (635KB)
|
|
摘要:
The departure from linear response which often occurs at dilute fluoride concentrations of the calibration curve reduces the sensitivity of the electrode. The linear portion of the standard curve may be extended to lower fluoride levels by dilution of the buffer itself. TISAB III M. tri-Ammonium citrate (TAC) is the superior of the eleven buffer systems examined in terms of masking ability. Of the potentially interfering species studied, only Al and Mg pose interference problems.
ISSN:0003-2719
DOI:10.1080/00032718108081423
出版商:Taylor & Francis Group
年代:1981
数据来源: Taylor
|
4. |
Water and Organic Solvent Adducts on Metal Chelates |
|
Analytical Letters,
Volume 14,
Issue 7,
1981,
Page 519-529
MadhuriK. Raut,
C.E. Meloan,
Preview
|
PDF (350KB)
|
|
摘要:
The number of water and organic solvent molecule adducts surrounding several ligands and metal chelates were determined in both the aqueous and organic phases. Data is presented to show that these adducts change in number during an extraction.
ISSN:0003-2719
DOI:10.1080/00032718108081424
出版商:Taylor & Francis Group
年代:1981
数据来源: Taylor
|
5. |
Spectrophotometric Determination of Sulfate by Solvent Extraction with Nonionic Surfactant Span 20 and Crystal Violet |
|
Analytical Letters,
Volume 14,
Issue 7,
1981,
Page 531-534
Shigeya Sato,
Etsuro Iwamoto,
Yuroku Yamamoto,
Preview
|
PDF (111KB)
|
|
摘要:
The sulfate ion is extracted into toluene with nonionic surfactant span 20 and crystal violet. A linear calibration curve was obtained between the absorbance due to crystal violet in the extract and sulfate concentrations over the range 2.5 × 10−5to 2.5 × 10−4mol 1−1(2.4 to 24 ppm) in the aqueous phase.
ISSN:0003-2719
DOI:10.1080/00032718108081425
出版商:Taylor & Francis Group
年代:1981
数据来源: Taylor
|
6. |
Critical Study of the Determination of Palladium by Graphite Furnace- Atomic Absorption Spectrometry |
|
Analytical Letters,
Volume 14,
Issue 7,
1981,
Page 535-552
János Fazakas,
Preview
|
PDF (596KB)
|
|
摘要:
The atomic absorption spectroscopic behaviour of palladium in a graphite furnace has been investigated. The determination is several ordes of magnitude more sensitive than the flame technique. The use of Tantalum coated tubes does not improve considerably the sensitivity but prolongs the lifetime of the furnaces.
ISSN:0003-2719
DOI:10.1080/00032718108081426
出版商:Taylor & Francis Group
年代:1981
数据来源: Taylor
|
7. |
Electron Impact and Chemical Ionization Mass Spectral Analysis of a Volatile Uranyl Derivative |
|
Analytical Letters,
Volume 14,
Issue 7,
1981,
Page 553-565
DennisJ. Reutter,
DennisR. Hardy,
Preview
|
PDF (348KB)
|
|
摘要:
Quadrupole mass spectral analysis of the volatile uranium ligand complex bis (1,1,1,5,5,5-hexafluoro-2,4 pentanedionato) dioxouranium-di-n-butyl sulfoxide is described utilizing electron impact (EI) and methane chemical ionization (CI) ion sources. All major ions are tentatively identified and the potential usefulness of this complex for determining uranium isotope 235U/238Uabundance is demonstrated.
ISSN:0003-2719
DOI:10.1080/00032718108081427
出版商:Taylor & Francis Group
年代:1981
数据来源: Taylor
|
8. |
Editorial board page for “Analytical Letters”, Volume 14, Number 7 |
|
Analytical Letters,
Volume 14,
Issue 7,
1981,
Page -
Preview
|
PDF (99KB)
|
|
摘要:
This is a scanned image of the original Editorial Board page(s) for this issue.
ISSN:0003-2719
DOI:10.1080/00032718108081420
出版商:Taylor & Francis Group
年代:1981
数据来源: Taylor
|