1. |
Derivatives of Rhodanine as Spectrophotometric Analytical Reagents. Determination of Copper |
|
Analytical Letters,
Volume 17,
Issue 13,
1984,
Page 1447-1462
G. Galán Alfonso,
J.L. Gómez Ariza,
A.Guiraum Pérez,
Preview
|
PDF (399KB)
|
|
摘要:
The reaction between Cu(I) and four non pyridinic derivatives of rhodanine (5-(phenyl)methylene-rhodanine (BARH), 5-(0-hydroxy-phenyl) methylenerhodanine (SARH), 5-(p-methoxy-phenyl) methylene-rhodanine (AARH) and 5-indolyl-(3)-methylene-rhodanine (IARH)) have been considered. the influence of the different experimental parameters on the formation of the complexes was studied, and the optimum conditions for the determination of copper were established. The indol-(3)-al derivative was selected among these because of the greater sensitivity of the metal reaction. The precision of the procedure, expressed in terms of relative standard deviation was 1.1 %. The methods have been applied to the determination of copper in several constrasted samples. Finally, these derivatives of rhodanine were compared with others classical reagents used in the photometric determination of copper.
ISSN:0003-2719
DOI:10.1080/00032718408065320
出版商:Taylor & Francis Group
年代:1984
数据来源: Taylor
|
2. |
Statistical Reexamination of Some Interference Patterns in the Determination of Calcium in Wheat (Triticum) by Atomic Absorption Spectrophotometry in an Air/Acetylene Flame |
|
Analytical Letters,
Volume 17,
Issue 13,
1984,
Page 1463-1472
DanI. Seracu,
Preview
|
PDF (275KB)
|
|
摘要:
The paper aims to statistically reexamine some interfereces that appear in the analysis of calcium by flame atomic absorption spectrophotometry in wheat (Triticum) sample, in the first vegetation stage.
ISSN:0003-2719
DOI:10.1080/00032718408065321
出版商:Taylor & Francis Group
年代:1984
数据来源: Taylor
|
3. |
Determination of Aluminium in Dialysis Fluids and Graphite-Tube Furnace Atomic Absorption Spectroscopy Using the l'Vov Platform |
|
Analytical Letters,
Volume 17,
Issue 13,
1984,
Page 1473-1486
Francesco Fagioli,
Luca Scanavini,
Clinio Locatelli,
Paolo Gilli,
Preview
|
PDF (466KB)
|
|
摘要:
A method was developed for aluminium determination in dialysis fluids by graphite-tube furnace atomic absorption spectroscopy utilizing the L'vov platform.
ISSN:0003-2719
DOI:10.1080/00032718408065322
出版商:Taylor & Francis Group
年代:1984
数据来源: Taylor
|
4. |
Detection and Spectrophotometric Determination of Uranyl Ion with Erichromcyanine R |
|
Analytical Letters,
Volume 17,
Issue 13,
1984,
Page 1487-1497
S.Z. Qureshi,
Reeta Bansal,
Khursheed Anwar,
Preview
|
PDF (308KB)
|
|
摘要:
Colour reaction has been studied for the identification and the spectrophotometric determination of uranyl ion with Erichromcyanine R. The detection limit was 7 μg. Beers law is obeyed in the concentration range containing 13 μg to 125 μg/10 ml of uranium.
ISSN:0003-2719
DOI:10.1080/00032718408065323
出版商:Taylor & Francis Group
年代:1984
数据来源: Taylor
|
5. |
Carbon-Filled Polymer Paste Ion-Selective Probes |
|
Analytical Letters,
Volume 17,
Issue 13,
1984,
Page 1499-1509
C.R. Hoffmann,
M.R. Haskard,
D.E. Mulcahy,
Preview
|
PDF (252KB)
|
|
摘要:
Inexpensive, disposable, carbon-filled polymer paste electrodes activated by a superficial layer of electro-active powder are reported. Sensors for silver, copper, lead and cadmium, halides, nitrate, pH and redox were thus prepared.
ISSN:0003-2719
DOI:10.1080/00032718408065324
出版商:Taylor & Francis Group
年代:1984
数据来源: Taylor
|
6. |
Simultaneous Determination of Selenocyanate and Thiocyanate Ions in the Presence of Cyanide by Oxidation withbis(Trifluoroacetoxy) iodobenzene |
|
Analytical Letters,
Volume 17,
Issue 13,
1984,
Page 1511-1517
I.N. Papadoyannis,
J.A. Stratis,
A.N. Anthemidis,
Preview
|
PDF (203KB)
|
|
摘要:
An investigation of the use of potentiometric titrations of selenocyanate and thiocyanate aqueous solutions, in the presence of cyanide ions, with bis (trifluoroacetoxy) iodobenzene in acetonitrile and then the gravimetric determination of the products of the reactions, elemental selenium and sulphate ions, has been carried out.
ISSN:0003-2719
DOI:10.1080/00032718408065325
出版商:Taylor & Francis Group
年代:1984
数据来源: Taylor
|
7. |
Adsorptive Stripping Voltammetry of Some Triazine- and Nitro Group-Containing Pesticides |
|
Analytical Letters,
Volume 17,
Issue 13,
1984,
Page 1519-1531
H. Beňadiková,
R. Kalvoda,
Preview
|
PDF (385KB)
|
|
摘要:
The application of adsorptive stripping analysis in combination with differential pulse voltammetry for the determination of some triazine- and nitro group- containing pesticides like Dinobutone, DNOK, Ametryne and Prometryne is described. Conditions for determinations in the concentration range from approx. 0.1 to 50 ppb are given.
ISSN:0003-2719
DOI:10.1080/00032718408065326
出版商:Taylor & Francis Group
年代:1984
数据来源: Taylor
|
8. |
Hplc Method for Kinetic Study of Mutarotation of Sugars |
|
Analytical Letters,
Volume 17,
Issue 13,
1984,
Page 1533-1538
M. Moriyasu,
A. Kato,
M. Okada,
Y. Hashimoto,
Preview
|
PDF (158KB)
|
|
摘要:
A high-performance liquid chromatographic (HPLC) method was established for kinetic studies of the interconversion (mutarotation) between pyranose sugar anomers in solution. At very low temperature, HPLC chromatograms of each sugar indicated the concentrations of each anomer in the state prior to the HPLC analysis. Thus, when one of the pyranose anomers obtained by recrystallization was dissolved into water and was analyzed by HPLC repeatedly, gradual changes in the chromatogrphic patterns were observed. The equilibrium concentrations of each sugar anomer in different solvents were found to vary, which was also investigated by HPLC.
ISSN:0003-2719
DOI:10.1080/00032718408065327
出版商:Taylor & Francis Group
年代:1984
数据来源: Taylor
|
9. |
Investigation of Instrument Parameters for the Application of Peroxyoxalate Cheminescence Detection to Microbore Chromatography |
|
Analytical Letters,
Volume 17,
Issue 13,
1984,
Page 1539-1552
MaryLynn Grayeski,
AndrewJ. Weber,
Preview
|
PDF (383KB)
|
|
摘要:
Peroxyoxalate chemiluminescence generated by the reaction of an oxalate and hydrogen peroxide in the presence of a fluorophor was evaluated as a detection system for microbore liquid chromatography. The results of studies on instrumental parameters show that the signal is increased with short reaction lines, increasing flow cell volume, and enhanced response through detectors with improved optics.
ISSN:0003-2719
DOI:10.1080/00032718408065328
出版商:Taylor & Francis Group
年代:1984
数据来源: Taylor
|
10. |
Erratum |
|
Analytical Letters,
Volume 17,
Issue 13,
1984,
Page 1553-1553
Preview
|
PDF (18KB)
|
|
ISSN:0003-2719
DOI:10.1080/00032718408065329
出版商:Taylor & Francis Group
年代:1984
数据来源: Taylor
|