1. |
Observations on Sampling Control Sera: Distributions of Chemistry Quality Control Values |
|
Analytical Letters,
Volume 4,
Issue 12,
1971,
Page 807-817
RobertE. Wenk,
Preview
|
PDF (233KB)
|
|
摘要:
Data, obtained in quality control programs in automated clinical chemistry systems are often not normally distributed. Falsely assuming that the data is Gaussian produces errors in classifying patients, and in statistical inferences drawn from parametric tests.
ISSN:0003-2719
DOI:10.1080/00032717108066068
出版商:Taylor & Francis Group
年代:1971
数据来源: Taylor
|
2. |
A New Colorimetric Procedure for Blood Alcohol Determination |
|
Analytical Letters,
Volume 4,
Issue 12,
1971,
Page 819-835
SidneyB. Rosalki,
Preview
|
PDF (562KB)
|
|
摘要:
A new colorimetric procedure for blood alcohol determination is described. Blood proteins are precipitated, and the protein-free supernatant incubated with nicotinamide-adenine dinucleotide (NAD), alcohol dehydrogenase (ADH), nitro blue tetrazolium (nitro BT) and phenazine methosulphate (PMS). Ethanol in the sample reduces the NAD, and the reduced NAD so formed reduces nitro BT to a coloured formazan, PMS serving as an intermediate electron carrier. The reaction is allowed to proceed to completion and colour formation quantitatively relates to sample alcohol concentration. An ethanol standard of known concentration is included with each batch of determinations and sample alcohol concentration calculated from this. The method permits the examination of large numbers of samples with rapidity and precision and without the need for specialized apparatus. Comparison with an ultra-violet enzymatic procedure for blood alcohol determination, gave excellent agreement.
ISSN:0003-2719
DOI:10.1080/00032717108066069
出版商:Taylor & Francis Group
年代:1971
数据来源: Taylor
|
3. |
Quantitative Determination of Nortriptyline And Desmethylnortriptyline In Human Plasma By Combined Gas Ciiromatography - Mass Spectrometry |
|
Analytical Letters,
Volume 4,
Issue 12,
1971,
Page 837-849
Olof Borgå,
Lena Palmér,
Allan Linnarsson,
Bo Holmstedt,
Preview
|
PDF (386KB)
|
|
摘要:
A quantitative method has been developed for the determination of the tricyclic antidepressant drug nortriptyline in plasma, utilizing a combined technique of gas chromatography - mass spectrometry called mass fragmentography. A metabolite, desmethylnortriptyline, may be analyzed in the same run. The compounds are first converted to their heptafluorobutyranide derivatives. A complete chromatogram takes less than five minutes. Quantitive determinations under the present conditions are possible down to a few nanograms of nortriptyline per milliliter. There is a good correlation between the new method and that previously used which was based uponin vitro311-acetylation labelling.
ISSN:0003-2719
DOI:10.1080/00032717108066070
出版商:Taylor & Francis Group
年代:1971
数据来源: Taylor
|
4. |
Evaluation Of Some Methods For 17- Ketosteroids In Urine |
|
Analytical Letters,
Volume 4,
Issue 12,
1971,
Page 851-856
Hilda Schonwald,
Dusanka Mikac-devic,
Preview
|
PDF (195KB)
|
|
摘要:
Three procedure for 17-ketosteroids are compared: The method of Callow et al., the method of Drekter et al. and the method of Corker et al. Good correlation has been found between results obtained by the methods of Callow and Corker. Analyses of single analytical steps showed that Drekter's method gives in some cases too high results because non-specific chromogens are included when readings are taken only at 520 nm. Of these three procedures that of Corker et al. is proposed as the method of choice.
ISSN:0003-2719
DOI:10.1080/00032717108066071
出版商:Taylor & Francis Group
年代:1971
数据来源: Taylor
|
5. |
Time-Resolved Spark-Source Mass Spectrometry; The Effect Of Spark Duration On Ion Intensity And Precision Of Analysis |
|
Analytical Letters,
Volume 4,
Issue 12,
1971,
Page 857-865
JamesC. Franklin,
JohnA. Dean,
Preview
|
PDF (313KB)
|
|
摘要:
A radio-frequency probe and a synchronized electronic ion-beam chapper have been used to determine ion-intensity variation with spark duration. Large peaks in multiply charged ion intensities are detected in the early stages of the radio-frequency spark, while later in the spark period the singly charged species predominate. The effects of these variations on the precision of analysis have been determined. A gate was selected in the spark pulse, and a factor of two increase in precision was obtained.
ISSN:0003-2719
DOI:10.1080/00032717108066072
出版商:Taylor & Francis Group
年代:1971
数据来源: Taylor
|
6. |
Formation Constants And Metal To Ligand Ratios For Calcein Blue- Metal Complexes |
|
Analytical Letters,
Volume 4,
Issue 12,
1971,
Page 867-872
David Phillips,
Paul Brignaca,
Preview
|
PDF (187KB)
|
|
摘要:
The formation constants of Calcein Blue-cadmium (II) and lead (II) complexes as well as their ligand to metal ratios were determined by a polarographic technique. The formation constants of Calcein Blue-copper (II) and silver (I) complexes as well as their ligand to metal ratios were determined by a potentiometric technique.
ISSN:0003-2719
DOI:10.1080/00032717108066073
出版商:Taylor & Francis Group
年代:1971
数据来源: Taylor
|
7. |
On The Interpretation Of Errors In Counting Experiments |
|
Analytical Letters,
Volume 4,
Issue 12,
1971,
Page 873-882
LloydA. Currie,
Preview
|
PDF (382KB)
|
|
摘要:
Digital experiments, such as the measurement of radioactivity, are usually characterized by random errors which follow the Binomial or Poisson distribution. Three types of difficulty which commonly arise in the statistical treatment of such experiments include
ISSN:0003-2719
DOI:10.1080/00032717108066074
出版商:Taylor & Francis Group
年代:1971
数据来源: Taylor
|
8. |
The Extraction And Recovery Of Polychlorinated Biphenyls (PCB) Using Porous Polyurethane Foam |
|
Analytical Letters,
Volume 4,
Issue 12,
1971,
Page 883-886
H.D. Gesser,
A. Chow,
F.C. Davis,
J.F. Uthe,
J. Reinke,
Preview
|
PDF (166KB)
|
|
摘要:
A fast and efficient method has been developed for the extraction and concentration of PCB from water. The method uses porous polyurethane foam as the absorption column for the PCB which is eluted with acetone and hexane for G. C. analysis.
ISSN:0003-2719
DOI:10.1080/00032717108066075
出版商:Taylor & Francis Group
年代:1971
数据来源: Taylor
|
9. |
Cathodic Stripping Voltammetry Of Cerium |
|
Analytical Letters,
Volume 4,
Issue 12,
1971,
Page 887-892
J. Dolezal,
E. Hrabánková,
V. Maěín,
Preview
|
PDF (214KB)
|
|
摘要:
The experimental conditions for the accumulation of cerium as insoluble Ce3(PO4)4on a platinum indicator electrode were studied. The determination of cerium down to 0.01% in oxides of other lanthanides is described.
ISSN:0003-2719
DOI:10.1080/00032717108066076
出版商:Taylor & Francis Group
年代:1971
数据来源: Taylor
|
10. |
Theory of Precision in Linear Titration Curves |
|
Analytical Letters,
Volume 4,
Issue 12,
1971,
Page 893-899
PeterW. Carr,
Stephan Onisick,
Preview
|
PDF (241KB)
|
|
摘要:
Error propagation in linear titration methods are considered in terms of the precision in measurement of the slopes and intercepts of the titration curve. Simulated curves including random errors were analyzed. The results indicate that the analytical precision is independent of the angle between the curves when the difference in slopes in fixed.
ISSN:0003-2719
DOI:10.1080/00032717108066077
出版商:Taylor & Francis Group
年代:1971
数据来源: Taylor
|