1. |
Imaging characteristics of x‐ray capillary optics in digital mammography |
|
Memoirs and Proceedings of the Chemical Society,
Volume 23,
Issue 2,
1998,
Page 187-196
David G. Kruger,
Carmen C. Abreu,
Eric G. Hendee,
Armen Kocharian,
Walter W. Peppler,
Charles A. Mistretta,
Carolyn A. MacDonald,
Preview
|
PDF (802KB)
|
|
摘要:
Computed radiography (CR) has shown promise in digital mammographic screening due to its good low spatial frequency MTF and its relatively wide exposure latitude. The CR image format has not gained acceptance clinically because of reduced high spatial frequency resolution as compared to film‐screen images. X‐ray capillary optics, aligned between the breast and CR phosphor imaging plate, will capture primary x‐ray photons almost exclusively. Due to the very small angle of acceptance, scattered photons angled more than about 1.6×10−3radians from primary trajectory will not be accepted at the capillary optic entrance. The virtual elimination of detected scatter means almost 100% of the possible primary contrast should be visible in the image. In addition, the image can be magnified without focal spot blurring. Effective resolution of CR images can be increased by a factor equal to that magnification. Clinical implementation of future capillary optics are expected to be either in the form of a large, stationary, post‐patient optic that accepts primary from the entire breast or a fan‐shaped optic that is scanned across the breast. Measurements of a test capillary optic showed a reduction of scatter fraction to 0.018. Images of a lucite contrast detail phantom revealed a corresponding increase in image contrast when compared to anti‐scatter grid and no grid methods. Spectral transmission measurements using a high‐purity germanium detector showed good primary transmission (45%–50%) in the mammographic energy range. The MTF measurements of both stationary and scanned capillary optics showed improvement at the 5% MTF level to 8.4 mm−1for scanned optics and 9.2 mm−1for stationary optics representing a 68% and 84% respective increase over the CR MTF without magnification or capillary optics.
ISSN:0269-3127
DOI:10.1118/1.597703
出版商:American Association of Physicists in Medicine
年代:1998
数据来源: WILEY
|
2. |
Three‐dimensional reconstruction of vascular trees. Theory and methodology |
|
Memoirs and Proceedings of the Chemical Society,
Volume 23,
Issue 2,
1998,
Page 197-204
C. J. Henri,
T. M. Peters,
Preview
|
PDF (805KB)
|
|
摘要:
In this paper we examine the few‐view reconstruction problem as it applies to imaging vascular trees. A fully automated reconstruction algorithm is described that circumvents the traditional “correspondence problem,” using only notions ofconsistencyandconnectivity. It is assumed that the vascular tree is a connected structure and that its centerlines have been identified in three or more images. The first of three steps in the procedure involves generating a connected structure that represents the multiplicity of solutions that are consistent with any two (different) projections. The second step assigns to each branch in this structure a measure of agreement based on its relationship with one or more additional views of the vasculature. The problem then becomes one of propagating this information, via connectivity relationships and consistency checks, throughout the above structure to distinguish between the branches comprising the imaged structure and the accompanying artifacts. In this paper we present the theory and methodology of the technique, while in a companion paper we address the issue of validation via simulations and experiments. Together, these papers shed some light on why ambiguities arise and often lead to errors in the few‐view reconstruction problem. Strategies to handle these errors are described and results are presented that demonstrate the ability to obtain adequate reconstructions with as few as three distinct views.
ISSN:0269-3127
DOI:10.1118/1.597704
出版商:American Association of Physicists in Medicine
年代:1998
数据来源: WILEY
|
3. |
Dual‐slice spiral versus single‐slice spiral scanning: Comparison of the physical performance of two computed tomography scanners |
|
Memoirs and Proceedings of the Chemical Society,
Volume 23,
Issue 2,
1998,
Page 205-220
Yun Liang,
Robert A. Kruger,
Preview
|
PDF (1338KB)
|
|
摘要:
In this paper we deal with two types of spiral scanners; one is a single‐slice spiral scanner, while the other employs dual‐slice technology into spiral scanning. Physical performance parameters, including image noise, contrast resolution, spatial resolution (transversal and longitudinal), and radiation exposure are measured. Computer simulations based on two interpolation methods (180° and 360° linear interpolation) are also used in evaluating the slice‐sensitivity profile (SSP) and noise. The results show that the noise behaves in the same way for both types of scanners. The noise change, relative to that of the standard scan with the same scanning parameters, depends solely on the interpolation algorithm. Table speed and scanner geometry (either single slice or dual slice) have no effect on the noise value. For the given table speed, as well as individual detector collimation (slice width) the dual‐slice scan results in better longitudinal resolution (SSP) compared to a single‐slice scan if the scan is obtained with nonoverlapping slices (pitch greater than 2). This is because the dual‐slice scan obtains twice the number of nonoverlapped projections for the same length, which reduces the degradation of the slice profile by using more densely arranged projections (in the longitudinal direction) for the interpolation. In the dual‐slice scanner the workable scan rate is extended up to pitch 4 compared to a pitch of 2 for the single‐slice scanner. Therefore, the dual‐slice spiral scanner is preferred in applications requiring an increased scan rate with comparative image quality.
ISSN:0269-3127
DOI:10.1118/1.597705
出版商:American Association of Physicists in Medicine
年代:1998
数据来源: WILEY
|
4. |
A general approach to the reconstruction of x‐ray helical computed tomography |
|
Memoirs and Proceedings of the Chemical Society,
Volume 23,
Issue 2,
1998,
Page 221-229
Jiang Hsieh,
Preview
|
PDF (844KB)
|
|
摘要:
Helical Computed Tomography (HCT) has become the method of choice for many routine clinical studies. The advantages of HCT include the capability of scanning a complete anatomical volume in a single breath hold, the capability of generating images at any desired location, and the improved patient throughput. However, these advantages come at the expense of some image quality compromises. This is mainly caused by the fact that the projection set is inherently incomplete and inconsistent, due to the constant patient translation during the data acquisition process. In this paper, we will briefly review the research work performed in this area and present a more general approach to the problem. We give two specific examples of the general approach and compare the performance of one of the examples with one of the best methods available today.
ISSN:0269-3127
DOI:10.1118/1.597706
出版商:American Association of Physicists in Medicine
年代:1998
数据来源: WILEY
|
5. |
Measurement of quantum noise in fluoroscopic systems for portal imaging |
|
Memoirs and Proceedings of the Chemical Society,
Volume 23,
Issue 2,
1998,
Page 231-238
Dennis W. Mah,
J. A. Rowlands,
J. Alan Rawlinson,
Preview
|
PDF (693KB)
|
|
摘要:
In fluoroscopic portal imaging systems, a metal plate is bonded to a phosphor screen and together these act as the primary x‐ray sensor. The light from the screen is collected and imaged by a lens on the target of a video camera. The demagnification (M) between the large area of the phosphor being imaged and the small active area of the video camera results in poor optical coupling between the screen and the video camera. Consequently x‐ray quantum noise is small compared to other noise sources. By reducing the demagnification, the light from the screen is collected more efficiently, so we were able to increase the x‐ray quantum noise relative to other noise sources and thus unambiguously identify it. The noise power spectrum was measured as a function ofMto determine the relationship between the x‐ray quantum noise, shot noise, and amplifier noise. It was found by extrapolation to clinical demagnifications that the amplifier noise dominates x‐ray quantum noise at all spatial frequencies, but the shot noise was less than the x‐ray quantum noise at low spatial frequencies. For low spatial frequencies, this implies that a secondary quantum sink can be avoided. If amplifier noise could be sufficiently reduced, x‐ray quantum limited images could be obtained in clinical systems at low spatial frequencies.
ISSN:0269-3127
DOI:10.1118/1.597794
出版商:American Association of Physicists in Medicine
年代:1998
数据来源: WILEY
|
6. |
Radiation dose and image quality of double‐loaded cassettes |
|
Memoirs and Proceedings of the Chemical Society,
Volume 23,
Issue 2,
1998,
Page 239-240
Charles A. Kelsey,
Fred A. Mettler,
Lisa M. Sullivan,
Preview
|
PDF (197KB)
|
|
摘要:
Some U.S. hospitals double‐load x‐ray cassettes for certain procedures. Loading two films in the same cassette for portable emergency room (ER), intensive care unit (ICU), or operating room radiographs provides both the referring clinicians and the radiologists with immediate images. Our study demonstrates a cost increase of 15%, an increase in air kerma for a chest x ray from 0.12 to 0.35 mGy (12–35 mrad), slight differences in optical density, image contrast, and spatial resolution under double‐loading conditions. Our study shows that double loading cassettes may improve patient care by economically expediting the communication of radiographic findings. The decision to double load portable ICU or ER cassettes must be based on a balance of factors.
ISSN:0269-3127
DOI:10.1118/1.597708
出版商:American Association of Physicists in Medicine
年代:1998
数据来源: WILEY
|
7. |
A mathematical spread sheet application for production of entrance skin exposure nomograms |
|
Memoirs and Proceedings of the Chemical Society,
Volume 23,
Issue 2,
1998,
Page 241-242
Michael D. Harpen,
Preview
|
PDF (115KB)
|
|
ISSN:0269-3127
DOI:10.1118/1.597711
出版商:American Association of Physicists in Medicine
年代:1998
数据来源: WILEY
|
8. |
Spatial mapping of the percentage cellularity in human bone marrow using magnetic resonance imaging |
|
Memoirs and Proceedings of the Chemical Society,
Volume 23,
Issue 2,
1998,
Page 243-250
Douglas Ballon,
Ann A. Jakubowski,
Martin C. Graham,
Erika Schneider,
Jason A. Koutcher,
Preview
|
PDF (685KB)
|
|
摘要:
A noninvasive assay for the spatial distribution of the percentage cellularity in human bone marrow is presented. Twelve individuals were studied using two magnetic resonance imaging techniques: (1) fast spin echo imaging with frequency selective presaturation, and (2) three‐point chemical shift imaging. The data were compared to results obtained using a previously validated stimulated echo spectroscopic method. The results of this study demonstrate that a measure of the percentage cellularity in bone marrow is possible using magnetic resonance imaging techniques provided that high‐quality water or lipid suppression is achieved across the region of interest. Since the method is applicable to bone marrow at any anatomic location, it may prove useful in dosimetric calculations during and after a course of internal or external beam radiotherapy.
ISSN:0269-3127
DOI:10.1118/1.597796
出版商:American Association of Physicists in Medicine
年代:1998
数据来源: WILEY
|
9. |
Correction of motion artifacts in linogram and projection reconstruction MRI using geometry and consistency constraints |
|
Memoirs and Proceedings of the Chemical Society,
Volume 23,
Issue 2,
1998,
Page 251-262
Neville Gai,
Leon Axel,
Preview
|
PDF (1300KB)
|
|
摘要:
Motion results in various artifacts such as blurring and streaks in clinical imaging of subjects based on reconstruction from projections. We model subject motion‐induced artifacts due to scaling, translational and rotational motion. A correction algorithm based on the Ludwig–Helgason consistency conditions is derived here. These conditions are satisfied whenever the projection data are consistent. We apply the algorithm to simulated data collected on linogram (LR) and projection reconstruction (PR) geometries, and to real PR geometry data, in magnetic resonance imaging (MRI). The results show that motion‐induced in‐plane, interview artifacts can be reduced with application of the algorithm. The algorithm is general enough to be applied to certain other cases arising in tomographic imaging.
ISSN:0269-3127
DOI:10.1118/1.597713
出版商:American Association of Physicists in Medicine
年代:1998
数据来源: WILEY
|
10. |
Transmission imaging of large attenuators using a slant hole collimator on a three‐headed SPECT system |
|
Memoirs and Proceedings of the Chemical Society,
Volume 23,
Issue 2,
1998,
Page 263-272
Michael A. King,
Dershan Luo,
Seth T. Dahlberg,
Bernard J. Villegas,
Bill C. Penney,
Hugh T. Morgan,
Preview
|
PDF (1164KB)
|
|
摘要:
By combining conjugate views, truncation‐free attenuation profiles of patients can be obtained by using slant hole collimators on three‐headed SPECT systems. The alterations in reconstruction algorithms necessary for use with slant hole collimators and potential image artifacts are discussed. Based on an evaluation of the size of objects that can be imaged without truncation and the size of the overlap region in the conjugate views, a 15° slant angle was determined to be optimal. Studies with a 30° slant hole collimator verified the ability of slant hole transmission imaging to provide accurate, truncation‐free attenuation maps of a 56 cm lateral width phantom. The center of rotation was determined to be dependent on the slant angle and radius of rotation of the slant collimator. These studies also demonstrated that the spatial resolution in the transaxial plane of the attenuation maps depends on radius of rotation of the slant hole collimator, but does not depend on the radius of rotation of an uncollimated transmission source. A multiline transmission source was investigated for use with estimating the attenuation map in Tc‐99m labeled sestamibi perfusion imaging.
ISSN:0269-3127
DOI:10.1118/1.597715
出版商:American Association of Physicists in Medicine
年代:1998
数据来源: WILEY
|