1. |
Optometry‐Ophthalmology – The Future |
|
American Journal of Optometry and Physiological Optics,
Volume 55,
Issue 1,
1978,
Page 1-7
Albert Lemoine,
Preview
|
PDF (354KB)
|
|
ISSN:0093-7002
出版商:OVID
年代:1978
数据来源: OVID
|
2. |
Dose‐Response Effects of Corneal Anesthetics |
|
American Journal of Optometry and Physiological Optics,
Volume 55,
Issue 1,
1978,
Page 8-14
KENNETH POLSE,
RODERICK KEENER,
MICHAEL JAUREGUI,
Preview
|
PDF (414KB)
|
|
摘要:
With double-masking procedures, the dose-response curves for 0.1, 0.2, and 0.4% benoxinate and 0.125, 0.25, and 0.50% proparacaine hydrochloride were determined by monitoring changes in corneal touch threshold after applying each anesthetic. The level of corneal anesthesia necessary for applanation tonometry was also determined. The maximum increase in threshold that could be measured following instillation of 50 μl of the drug was 200 mg/mm2 All 6 anesthetic solutions produced this amount of decreased corneal sensitivity. Recovery from the anesthetic was exponential for all concentrations; however, the lower doses had the shortest duration. For applanation tonometry, the corneal threshold for touch must be 75 mg/mm2 or higher. We conclude that a quarter to a half of the commonly used anesthetic dose is sufficient for routine tonometric evaluation.
ISSN:0093-7002
出版商:OVID
年代:1978
数据来源: OVID
|
3. |
Stability of Back‐Toric Prism‐Ballast Hydrogel Contact Lenses |
|
American Journal of Optometry and Physiological Optics,
Volume 55,
Issue 1,
1978,
Page 15-18
MICHAEL HARRIS,
MARY LACONIC,
JANE WARD,
Preview
|
PDF (202KB)
|
|
摘要:
We fitted each of 20 eyes with 3 different Hydrocurve(tm) contact lenses: (1) spherical with prism ballast, (2) back-toric without prism ballast, and (3) back-toric with prism ballast. We monitored the stability of the lenses. The prism-ballast lenses were generally stable on corneas with zero to 3.5 DK of with-the-rule toricity; the back-toric nonprism lenses were not stable.
ISSN:0093-7002
出版商:OVID
年代:1978
数据来源: OVID
|
4. |
The Ocular Effects of Ultraviolet Radiation |
|
American Journal of Optometry and Physiological Optics,
Volume 55,
Issue 1,
1978,
Page 19-35
DONALD PITTS,
Preview
|
PDF (1156KB)
|
|
摘要:
The author reviews the previous known effects of UV radiation on the eye together with results obtained on human and animal eyes in his laboratory during the past 11 years. Damage to the cornea and lens is assessed, classified, and discussed. Methods of calculating safe UV exposures and establishing characteristics of protective devices are presented.
ISSN:0093-7002
出版商:OVID
年代:1978
数据来源: OVID
|
5. |
Evaluation of 225 Consecutive Intraocular‐Lens Implants |
|
American Journal of Optometry and Physiological Optics,
Volume 55,
Issue 1,
1978,
Page 36-42
LOUIS PHILLIPS,
PENNY LIGHTHOLDER,
FRANCIS HURITE,
Preview
|
PDF (445KB)
|
|
摘要:
A retrospective study of the first 225 intraocular lens implants (IOL) performed by a single surgeon was conducted for this report. In complication rate and visual acuity assessed 4.5 months postoperatively, these patients (pseudophakes) compared very closely with 2 populations of aphakic patients who had had phacoemulsification surgery without lens implantation by the same surgeon. The majority of pseudophakes were left with moderate to low refractive errors. Patient satisfaction was found to be high. It appears that implantation of iris and capsular fixated intraocular lenses is a comparatively safe and in many cases advantageous procedure.
ISSN:0093-7002
出版商:OVID
年代:1978
数据来源: OVID
|
6. |
Water Flow Conductivity and Pore Diameter in Extended‐Wear Gel Lens Materials |
|
American Journal of Optometry and Physiological Optics,
Volume 55,
Issue 1,
1978,
Page 43-47
IRVING FATT,
Preview
|
PDF (313KB)
|
|
摘要:
The water flow conductivity of 3 high-water-content (70 to 85%) gel materials proposed for extended-wear contact lenses was measured. Pore diameter was calculated from these flow conductivities. High-water-content gels were found to have pore diameters in the range of 20 to 30 A compared with about 8 A for the lower-water-content HEMA gel. The larger pore diameter of extended-wear lenses will permit entry of drugs, hormones, and enzymes and thereby may pose new problems for wearers.
ISSN:0093-7002
出版商:OVID
年代:1978
数据来源: OVID
|
7. |
Static Fracture Resistance of Schott S‐1005 Lenses as a Function of Thickness |
|
American Journal of Optometry and Physiological Optics,
Volume 55,
Issue 1,
1978,
Page 48-51
A. SCAIEF,
STEVEN WOOD,
Preview
|
PDF (230KB)
|
|
摘要:
High-Lite S-1005 lenses (Schott Optical Company) of various center thicknesses were tested for static load fracture resistance. Chemically tempered High-Lite lenses of 1.7-mm center thickness were found to be equivalent in strength to 3.0-mm heat-tempered crown lenses; 1.34-mm chemically tempered High-Lite lenses were equivalent in strength to 2.07-mm heat-tempered crown lenses. These findings agree closely with earlier data on chemically tempered crown glass and therefore illustrate that chemically hardened lenses can be made significantly thinner than Z-80 specifications and still meet FDA strength requirements.
ISSN:0093-7002
出版商:OVID
年代:1978
数据来源: OVID
|
8. |
Modifying the Pattern of Prescribing Multiple Pairs of Glasses |
|
American Journal of Optometry and Physiological Optics,
Volume 55,
Issue 1,
1978,
Page 52-56
JESSE ROSENTHAL,
KENNETH SCHWARTZ,
Preview
|
PDF (365KB)
|
|
摘要:
The New York City Medicaid program uses computerized monitoring techniques as part of its effort to control the quality and utilization of services. The system can identify certain aberrant patterns of practice. For optometric services, one such practice by some providers is the prescribing of separate distance and near eyeglasses in lieu of bifocals. Sending a notification letter to these providers succeeded in modifying the practice. Computerized monitoring and associated roles for professionals are discussed.
ISSN:0093-7002
出版商:OVID
年代:1978
数据来源: OVID
|
9. |
Recording Monocular VEPs Under Binocular Conditions |
|
American Journal of Optometry and Physiological Optics,
Volume 55,
Issue 1,
1978,
Page 57-61
JAMES MAY,
ROGER CUMMINGS,
JOHN SIEGFRIED,
Preview
|
PDF (288KB)
|
|
摘要:
This report describes a technique for recording the visual evoked potential (VEP) arising from 1 eye under conditions of binocular pattern stimulation. The subject views a sinusoidally modulated vectographic checkerboard with orthogonally oriented polarizing filters before the eyes. This technique results in waveforms that contain monocular VEPs distributed in time. The technique is sensitive to interocular suppression and controls for the influence of various extraneous sources of variability. It is useful in clinical VEP testing.
ISSN:0093-7002
出版商:OVID
年代:1978
数据来源: OVID
|
10. |
A Foot‐Operated Camera l Trip for the Nikon Photo SII Lamp |
|
American Journal of Optometry and Physiological Optics,
Volume 55,
Issue 1,
1978,
Page 62-63
D. COCKBURN,
Preview
|
PDF (86KB)
|
|
摘要:
A simple foot-operated shutter cable frees both hands for holding the gonioscope lens and adjusting the Nikon slit lamp during photography of the recess of the anterior-chamber angle.
ISSN:0093-7002
出版商:OVID
年代:1978
数据来源: OVID
|