1. |
The current status of medical telemetry |
|
Journal of Medical Engineering&Technology,
Volume 4,
Issue 1,
1980,
Page 1-1
MeldrumS. J.,
Preview
|
PDF (121KB)
|
|
ISSN:0309-1902
DOI:10.3109/03091908009161078
出版商:Taylor&Francis
年代:1980
数据来源: Taylor
|
2. |
Tissue pH electrodes for clinical applications |
|
Journal of Medical Engineering&Technology,
Volume 4,
Issue 1,
1980,
Page 3-7
HarrisonD. K.,
WalkerW. F.,
Preview
|
PDF (550KB)
|
|
摘要:
The reduction of peripheral blood flow, which occurs during shock or in patients with occlusive arterial disease of the lower limb is accompanied by an increase in hydrogen ion activity in tissue cells. If this change could be measured, it could possibly be used as an indicator of tissue perfusion in such patients. Investigations have been carried out into various pH micro-electrode designs in order to construct one which could be used clinically to measure extracellular pH changes in skin. Experiments with antimony and externally insulated glass micro-electrodes demonstrated that these were unsatisfactory for the purpose. The successful design was insulated internally by means of a glass to glass fuse. It was robust, stable, sensitive and had a fast response time. Use of the electrode in normal volunteers produced reproducible skin pH values and demonstrated the feasibility of the system. Preliminary results using the micro-electrodes in patients indicate their possible application to the assessment of peripheral vascular disease, and to the monitoring of patients under intensive care.
ISSN:0309-1902
DOI:10.3109/03091908009161079
出版商:Taylor&Francis
年代:1980
数据来源: Taylor
|
3. |
A first-degree course in electronics, with medical instrumentation as a background topic |
|
Journal of Medical Engineering&Technology,
Volume 4,
Issue 1,
1980,
Page 7-11
JonesN. B.,
Preview
|
PDF (619KB)
|
|
摘要:
A course is described in which undergraduate students of electronics can study aspects of medical instrumentation throughout a three-year period. This course includes as much electronics as a normal B.Sc programme in Electronics but contains a background theme of medical engineering and bioengineering amounting to 20% of the total work load. The course is compared with two similar courses in Britain and also with courses abroad. Some consideration is given to the educational content of this course as well as to employment opportunities and social trends.
ISSN:0309-1902
DOI:10.3109/03091908009161080
出版商:Taylor&Francis
年代:1980
数据来源: Taylor
|
4. |
The design and use of appropriate health technologies for developing countries |
|
Journal of Medical Engineering&Technology,
Volume 4,
Issue 1,
1980,
Page 11-15
LomaxChristopher A.,
Preview
|
PDF (562KB)
|
|
摘要:
Health care in developing countries is discussed in terms of the administrative systems, medical manpower and technologies which are most appropriate to the economic and cultural environment in which they will be used. Appropriate technology must be preceded by appropriate research and development and those involved in the training of overseas students should critically examine the relevance of the course to the needs of the students.
ISSN:0309-1902
DOI:10.3109/03091908009161081
出版商:Taylor&Francis
年代:1980
数据来源: Taylor
|
5. |
Gravimetric plethysmography for measurement of blood flow in the leg |
|
Journal of Medical Engineering&Technology,
Volume 4,
Issue 1,
1980,
Page 16-19
WigginsP. A.,
LevesonS. H.,
KesterR. C.,
WildeD. T.,
Preview
|
PDF (487KB)
|
|
摘要:
The gravimetric plethysmograph measures blood flow in the limb in terms of the increase in weight which follows temporary venous occlusion. Following validation of the device, blood flow in the leg was evaluated in normal subjects and in patients with intermittent claudication. Measurement of the immediate hyperaemic response to a three-minute period of arterial occlusion proved to be very reproducible in patients with occlusive arterial disease of the legs.
ISSN:0309-1902
DOI:10.3109/03091908009161082
出版商:Taylor&Francis
年代:1980
数据来源: Taylor
|
6. |
The production of spinal jackets for children with spina bifida |
|
Journal of Medical Engineering&Technology,
Volume 4,
Issue 1,
1980,
Page 20-23
GriffithsJ. C.,
TaylorA. G.,
Preview
|
PDF (1634KB)
|
|
摘要:
This paper discusses the problems of spinal deformity and instability in spina bifida. A technique for suitable bracing is described and the available materials investigated.
ISSN:0309-1902
DOI:10.3109/03091908009161083
出版商:Taylor&Francis
年代:1980
数据来源: Taylor
|
7. |
A real-time spectrum analyser for ultrasonic Doppler signals, using a chirp-z-transform technique |
|
Journal of Medical Engineering&Technology,
Volume 4,
Issue 1,
1980,
Page 24-26
MacphersonP. C.,
MeldrumS. J.,
TunstallD. S.,
Preview
|
PDF (398KB)
|
|
ISSN:0309-1902
DOI:10.3109/03091908009161084
出版商:Taylor&Francis
年代:1980
数据来源: Taylor
|
8. |
Biomaterials |
|
Journal of Medical Engineering&Technology,
Volume 4,
Issue 1,
1980,
Page 26-29
WainW. H.,
Preview
|
PDF (538KB)
|
|
ISSN:0309-1902
DOI:10.3109/03091908009161085
出版商:Taylor&Francis
年代:1980
数据来源: Taylor
|
9. |
Books |
|
Journal of Medical Engineering&Technology,
Volume 4,
Issue 1,
1980,
Page 29-31
SwansonS. A. V.,
Preview
|
PDF (378KB)
|
|
摘要:
Human Joints and their Artificial Replacements.Walker, P.S., 1977 Charles C. Thomas, Springfield, Illinois. pp 510 + xiv. $49.50. ISBN 0398-0361-52A Short Textbook of Radiotherapy: Radiation Physics, Therapy and Oncology.Walter, J., Miller, H. and Bomford, C.K., 1979, Churchill Livingstone, Edinburgh. pp 299,£11.00. ISBN 0-443-01389-6Clinical engineering: principles and practices.Edited by John G. Webster and Albert M. Cook, 1979, Prentice/Hall International, pp 460,£16.25 ISBN 1313 77 37X
ISSN:0309-1902
DOI:10.3109/03091908009161086
出版商:Taylor&Francis
年代:1980
数据来源: Taylor
|
10. |
News, Trends&Techniques |
|
Journal of Medical Engineering&Technology,
Volume 4,
Issue 1,
1980,
Page 33-34
Preview
|
PDF (561KB)
|
|
ISSN:0309-1902
DOI:10.3109/03091908009161087
出版商:Taylor&Francis
年代:1980
数据来源: Taylor
|
|