|
1. |
Quality assurance of medical software |
|
Journal of Medical Engineering&Technology,
Volume 18,
Issue 1,
1994,
Page 1-10
CosgriffP. S.,
Preview
|
PDF (997KB)
|
|
摘要:
Quality assurance is a topical issue within the software industry, and various methodological solutions aimed at improving software quality have been proposed. Medical software is generally deemed safety-critical and, as such, should be subject to control procedures exceeding those applicable to general-purpose software. The user/purchaser of medical equipment has an important part to play in the drive for higher-quality medical software, and ways in which the user can influence commercial suppliers are outlined. The implications of existing and planned legislation are also discussed.
ISSN:0309-1902
DOI:10.3109/03091909409030782
出版商:Taylor&Francis
年代:1994
数据来源: Taylor
|
2. |
Three-dimensional measurements of skin surface topography by triangulation with a new laser profilometer |
|
Journal of Medical Engineering&Technology,
Volume 18,
Issue 1,
1994,
Page 11-21
AssoulM.,
ZahidiM.,
CorcuffP.,
MignotJ.,
Preview
|
PDF (2379KB)
|
|
摘要:
The fast measurement of furrows or wrinkles requires the use of a non-contact device. We have chosen a laser detector based on a triangulation principle, using position-sensitive detectors. This apparatus has a sensitivity of about 2–3μm for a vertical range>1 mm; this vertical range can reach 8 mm. There is no contact between the detector and the surface and this reduces the measurement time because, while data are being transmitted, there is no decrease in the scanning speed as with earlier methods. We describe the device and its technical characteristics. The limits of use are shown in the measurement of low-amplitude defects (>3–4μm) and of wide defects of≤8 mm. Examples of software possibilities and practical applications related to skin microrelief wrinkles and pathological cases, are also described.
ISSN:0309-1902
DOI:10.3109/03091909409030783
出版商:Taylor&Francis
年代:1994
数据来源: Taylor
|
3. |
Calculation of gait parameters direct from force plate readings |
|
Journal of Medical Engineering&Technology,
Volume 18,
Issue 1,
1994,
Page 22-28
KhodadadehS.,
Preview
|
PDF (521KB)
|
|
摘要:
Several parameters used in the assessment of pathological gait are normally determined by measurements obtained by means other than from force plate recordings. Methods are presented whereby parameters such as stride length, step length, cadence, single support lime, average forward velocity and angle of foot in contact with the force plate are determined directly from force plate recordings of the gait.
ISSN:0309-1902
DOI:10.3109/03091909409030784
出版商:Taylor&Francis
年代:1994
数据来源: Taylor
|
4. |
Evaluation |
|
Journal of Medical Engineering&Technology,
Volume 18,
Issue 1,
1994,
Page 35-38
Preview
|
PDF (390KB)
|
|
ISSN:0309-1902
DOI:10.3109/03091909409030787
出版商:Taylor&Francis
年代:1994
数据来源: Taylor
|
5. |
News, trends&techniques |
|
Journal of Medical Engineering&Technology,
Volume 18,
Issue 1,
1994,
Page 39-41
Preview
|
PDF (302KB)
|
|
ISSN:0309-1902
DOI:10.3109/03091909409030788
出版商:Taylor&Francis
年代:1994
数据来源: Taylor
|
6. |
New products |
|
Journal of Medical Engineering&Technology,
Volume 18,
Issue 1,
1994,
Page 42-44
Preview
|
PDF (961KB)
|
|
ISSN:0309-1902
DOI:10.3109/03091909409030789
出版商:Taylor&Francis
年代:1994
数据来源: Taylor
|
|