|
1. |
Statement Concerning the Use of Hepatitis‐associated Antigen Tests for Donor Screening in Blood Banks |
|
Transfusion,
Volume 11,
Issue 1,
1971,
Page 1-3
Preview
|
PDF (209KB)
|
|
ISSN:0041-1132
DOI:10.1111/j.1537-2995.1971.tb04366.x
出版商:Blackwell Publishing Ltd
年代:1971
数据来源: WILEY
|
2. |
Quantitative Hemagglutination Inhibition Studies of Blood‐group Substances |
|
Transfusion,
Volume 11,
Issue 1,
1971,
Page 4-15
M. B. Gibbs,
W. S. Collins,
J. R. Ortaldo,
C. Laffer,
Preview
|
PDF (707KB)
|
|
摘要:
Quantitative hemagglutination inhibition studies of the pre‐ and postimmune sera of nine human volunteers immunized with hog A substance have confirmed earlier findings that the character of the agglutinins is altered by immunization. Concomitant with immune antihog A antibody production, the slope of the probit‐log hemagglutination inhibition assay curve became steeper, the amount of hog A substance required to inhibit the agglutinins became smaller, and the rate of dissociation of hog‐A‐anti‐A complexes became slower. The observed differences in the reactivativities of these pre‐ and postimmune sera could be attributed to an increase in specificity and firmer binding of the antibodies to the inhibito
ISSN:0041-1132
DOI:10.1111/j.1537-2995.1971.tb04367.x
出版商:Blackwell Publishing Ltd
年代:1971
数据来源: WILEY
|
3. |
Isolation of a Substance with Blood ‐group P1Activity from Human Erythrocyte Stroma |
|
Transfusion,
Volume 11,
Issue 1,
1971,
Page 16-18
D. M. Marcus,
Preview
|
PDF (182KB)
|
|
摘要:
Lyophilized erythrocyte stroma were extracted with chloroform methanol, and a fraction with blood‐group P1activity was obtained by chromatography on columns of silicic acid followed by preparative thin‐layer chromatography. The active fraction contained at least two glycosphingolipids, and it is concluded, tentatively, that the erythrocyte P1antigen is a glycosphingoli
ISSN:0041-1132
DOI:10.1111/j.1537-2995.1971.tb04368.x
出版商:Blackwell Publishing Ltd
年代:1971
数据来源: WILEY
|
4. |
Leukocyte Transfusions |
|
Transfusion,
Volume 11,
Issue 1,
1971,
Page 19-24
I. M. Goldstein,
H. J. Eyre,
P. I. Terasaki,
E. S. Henderson,
R. G. Graw,
Preview
|
PDF (381KB)
|
|
摘要:
Tests for leukoagglutinins and lymphocytotoxic antibodies were performed on sera from 34 recipients of 78 transfusions of leukocytes obtained from donors with chronic myelogenous leukemia. The presence of preformed leukocyte alloantibodies directed against donor cells predisposed to transfusion reactions of variable severity and failure of the transfused cells to survive and circulate in their new host. Studiesin vitrodemonstrated that these antibodies could inhibit granulocyte phagocytosis and bactericidal capacity. Pretransfusion compatibility testing for transfusion of leukocytes is recommended. Leukocytes should not be given if they are agglutinated by the recipient's serum or if the lymphocytes show damage in lymphocytotoxicity tests.
ISSN:0041-1132
DOI:10.1111/j.1537-2995.1971.tb04369.x
出版商:Blackwell Publishing Ltd
年代:1971
数据来源: WILEY
|
5. |
Serum Hepatitis Specific Antigen (SH) in Commercial and Volunteer Sources of Blood |
|
Transfusion,
Volume 11,
Issue 1,
1971,
Page 25-27
C. E. Cherubin,
A. M. Prince,
Preview
|
PDF (190KB)
|
|
摘要:
Blood from various commercial sources used for transfusion at two New York City hospitals, samples from a large commercial blood bank, and samples from the city's major volunteer blood source, Were tested for SH antigen by the Ouchterlony technic. The different commercial sources averaged an antigen positive incidence of 1.2 per 100 units, whereas the volunteer source had less than one positive per thousand. The relative risk of transfusion hepatitis between the two sources was approximately 12: 1. This is in accord with follow‐up studies of patients. Improvements in the sensitivity of the antigen test and exclusion of positive units would reduce the absolute risk of posttransfusion hepatitis but would not be expected to alter the relative risk. Because of this, volunteer blood sources should be considered preferable to commercial sources, at least in large urban area
ISSN:0041-1132
DOI:10.1111/j.1537-2995.1971.tb04370.x
出版商:Blackwell Publishing Ltd
年代:1971
数据来源: WILEY
|
6. |
Increased Blood‐group A Activity in Urine of Patients with Renal Disease |
|
Transfusion,
Volume 11,
Issue 1,
1971,
Page 28-32
F. Ottensooser,
J. Pagenotto,
I. Nussenzveig,
Preview
|
PDF (267KB)
|
|
摘要:
The urines of secretor type A renal patients frequently contain more A substance than do urines of normal controls. Group A substance levels were not related to proteinuria, diagnosis, or severity of disease.
ISSN:0041-1132
DOI:10.1111/j.1537-2995.1971.tb04371.x
出版商:Blackwell Publishing Ltd
年代:1971
数据来源: WILEY
|
7. |
Maternal Anti‐LW |
|
Transfusion,
Volume 11,
Issue 1,
1971,
Page 33-35
L. L. DeVeber,
G. W. Clark,
M. Hunking,
M. Stroup,
Preview
|
PDF (199KB)
|
|
摘要:
Potent anti‐LW was detected in the serum of an LW‐negative mother when a direct antiglobulin test of the cord blood of her baby was found to be weakly positive. The baby showed minimal evidence of active hemolytic disease. The antibody decreased in titer over three years and, in contrast to earlier testing, will no longer distinguish Rh‐positive from Rh‐negativ
ISSN:0041-1132
DOI:10.1111/j.1537-2995.1971.tb04372.x
出版商:Blackwell Publishing Ltd
年代:1971
数据来源: WILEY
|
8. |
Preparation of Rabbit Antihuman Complement Reagent |
|
Transfusion,
Volume 11,
Issue 1,
1971,
Page 36-41
H. Rubin,
Preview
|
PDF (868KB)
|
|
摘要:
A method is described to prepare antisera primarily directed against complement components coating red blood cells. The method is based on the Milgrem technic of exposing rabbit red blood cells to human serum prior to their injection into the same rabbit. Modification of this method designed to enhance the binding of complement to the cells, namely prior trypsinization and exposure to human serum diluted in low ionic strength sucrose, has resulted in the production of potent anticomplement reagents that contain very little anti‐IgG after one short course of immunization. This reagent should be of value in the detection of complement binding antibodies in the blood ban
ISSN:0041-1132
DOI:10.1111/j.1537-2995.1971.tb04373.x
出版商:Blackwell Publishing Ltd
年代:1971
数据来源: WILEY
|
9. |
Microdetermination of Bilirubin Concentration by AutoAnalyzer |
|
Transfusion,
Volume 11,
Issue 1,
1971,
Page 42-46
R. E. Rosenfield,
C. Dabinsky,
J. B. Levine,
E. M. Berkman,
Preview
|
PDF (307KB)
|
|
摘要:
A microdetermination of neonatal serum bilirubin concentration by AutoAnalyzer consumes less than 100μliters of sample for two tests, requires less than 15 minutes to equilibrate the instrument and less than six minutes between time of sampling and time of read‐out. It provides especially accurate data between 10 and 25 mg bilirubin/100 ml and useful data between zero and 40 mg bilirubin/100 ml. The instrument is sufficiently simple to permit its operation on a 24‐hour basis by blood bank technologists not previously experienced in clinical chemi
ISSN:0041-1132
DOI:10.1111/j.1537-2995.1971.tb04374.x
出版商:Blackwell Publishing Ltd
年代:1971
数据来源: WILEY
|
10. |
A Tutorial on Linear Regression in Blood Banking |
|
Transfusion,
Volume 11,
Issue 1,
1971,
Page 47-58
L. Hyams,
J. Philpot,
Preview
|
PDF (652KB)
|
|
摘要:
The relationship between a set of independent and dependent variables can be evaluated by the least squares line. Methods are presented to calculate this line, to test the significance of intercept and slope, to estimate, and to predict.
ISSN:0041-1132
DOI:10.1111/j.1537-2995.1971.tb04375.x
出版商:Blackwell Publishing Ltd
年代:1971
数据来源: WILEY
|
|