1. |
Biologic Esthetic Restorations |
|
Journal of Esthetic and Restorative Dentistry,
Volume 4,
Issue 1,
1992,
Page 1-3
José Fortunato Ferreira Santos,
Joel Bianchi,
Preview
|
PDF (1780KB)
|
|
摘要:
Cases of serious coronal destruction were treated by bonding parts of extracted teeth to the coronal remnants by means of adhesives and photo‐activated composite resins. The long‐term clinical results have revealed very satisfactory clinical performance of the compounded restorations. No detrimental effects have been identif
ISSN:1496-4155
DOI:10.1111/j.1708-8240.1992.tb00707.x
出版商:Blackwell Publishing Ltd
年代:1992
数据来源: WILEY
|
2. |
Tunnel Restorations: A Review |
|
Journal of Esthetic and Restorative Dentistry,
Volume 4,
Issue 1,
1992,
Page 4-9
Joe Papa,
Peter R. Wilson,
Martin J. Tyas,
Preview
|
PDF (664KB)
|
|
摘要:
Conventional cavity designs are coming under increased scrutiny because of an increased emphasis on preservation of tooth substance. The tunnel restoration, when used with glass ionomer, may overcome some of the disadvantages of conventional cavity preparations. Justification for the use of the tunnel restoration is from a limited number of short‐term clinical observations and destructive laboratory testing of marginal ridge strength. The technique is not without shortcomings. Long‐term clinical and nondestructive laboratory trials examining the strength of teeth with tunnel restorations should be undertaken prior to its acceptance as a replacement for techniques in which the marginal ridge is remo
ISSN:1496-4155
DOI:10.1111/j.1708-8240.1992.tb00708.x
出版商:Blackwell Publishing Ltd
年代:1992
数据来源: WILEY
|
3. |
Conservative Treatment of Cervical Sensitivity |
|
Journal of Esthetic and Restorative Dentistry,
Volume 4,
Issue 1,
1992,
Page 6-6
M. Balanko,
R.E. Jordan,
Preview
|
PDF (1330KB)
|
|
摘要:
A highly effective, long‐lasting treatment of cervical sensitivity is presente
ISSN:1496-4155
DOI:10.1111/j.1708-8240.1992.tb00646.x
出版商:Blackwell Publishing Ltd
年代:1992
数据来源: WILEY
|
4. |
Editorial |
|
Journal of Esthetic and Restorative Dentistry,
Volume 4,
Issue 1,
1992,
Page 7-7
Ronald E. Jordan,
Preview
|
PDF (240KB)
|
|
ISSN:1496-4155
DOI:10.1111/j.1708-8240.1992.tb00644.x
出版商:Blackwell Publishing Ltd
年代:1992
数据来源: WILEY
|
5. |
Simplified Occlusal Anatomy for Posterior Composites |
|
Journal of Esthetic and Restorative Dentistry,
Volume 4,
Issue 1,
1992,
Page 8-10
Casimir A. Mazik,
Preview
|
PDF (3104KB)
|
|
摘要:
Direct posterior composites have had problems in the past and thus have not had wide acceptance. The newest generation materials overcome many of their previous shortcomings. Finishing with proper anatomy has been difficult and time‐consuming. An alternative to overfilling and then grinding in the anatomy is proposed. Using a prefilled tip allows small increments of composite to be placed without flowing and sagging. Each cusp is individually shaped and initially cured for 10 seconds. Every attempt is made not to overfill the preparation to avoid unnecessary grinding. The anatomy shapes up almost automatically, similar to P.K. Thomas waxing. With only minor adjustments and polishing with a polishing paste, time spent finishing is reduced. Natural looking, functional, and beautiful occlusal anatomy is now possible with this simple techniqu
ISSN:1496-4155
DOI:10.1111/j.1708-8240.1992.tb00647.x
出版商:Blackwell Publishing Ltd
年代:1992
数据来源: WILEY
|
6. |
Diastema Closure: A Case Report |
|
Journal of Esthetic and Restorative Dentistry,
Volume 4,
Issue 1,
1992,
Page 9-11
Harvey Putter,
Al Huberman,
Warren Scherer,
Preview
|
PDF (817KB)
|
|
摘要:
This clinical study describes two combined modalities of treatment, orthodontic and porcelain laminate placement, to facilitate diastema closure. Geristore, a dual‐cure fluoride‐releasing composite was mixed to bond orthodontic brackets in place. H6 elastic bands were used with the orthodontic brackets to close the diastemas sufficiently and to allow the placement of Cerlnate porcelain laminates to produce a beneficial cosmetic eff
ISSN:1496-4155
DOI:10.1111/j.1708-8240.1992.tb00709.x
出版商:Blackwell Publishing Ltd
年代:1992
数据来源: WILEY
|
7. |
Effect of Cavity Disinfection on Bond Strength to Dentin |
|
Journal of Esthetic and Restorative Dentistry,
Volume 4,
Issue 1,
1992,
Page 11-13
A. John Gwinnett,
Preview
|
PDF (299KB)
|
|
摘要:
The application of a disinfecting step in cavity preparation and tooth restoration is gaining wider acceptance. This study examined the effect of two commercially available disinfecting agents on the shear bond strength to dentin using a fourth generation dentin bonding agent. The agent tested permitted an evaluation of both dry and wet bonding techniques. It was found that the commercial preparations did not adversely affect shear bond strength to dentin in either the dry or wet application.
ISSN:1496-4155
DOI:10.1111/j.1708-8240.1992.tb00710.x
出版商:Blackwell Publishing Ltd
年代:1992
数据来源: WILEY
|
8. |
Financial Considerations Regarding Acquisition of the Siemens Cerec Computer Reconstruction System |
|
Journal of Esthetic and Restorative Dentistry,
Volume 4,
Issue 1,
1992,
Page 12-15
Justin Lee Altshuler,
David Jacobs,
Preview
|
PDF (587KB)
|
|
摘要:
There has been much interest in the in‐office fabrication of ceramic posterior restorations using computer‐aided design and computer‐aided manufacture (CAD‐CAM) units. One concern that practitioners have concerning the use of one of these systems is the initial expense of the CAD‐CAM unit for the office. This article deals with the financial implications involved when considering the purchase or lease of a CEREC (CAD
ISSN:1496-4155
DOI:10.1111/j.1708-8240.1992.tb00648.x
出版商:Blackwell Publishing Ltd
年代:1992
数据来源: WILEY
|
9. |
Bonding Composite to Glass lonomer with Adhesive Resin Cements |
|
Journal of Esthetic and Restorative Dentistry,
Volume 4,
Issue 1,
1992,
Page 13-15
Daryl Styner,
Warren Scherer,
James LoPresti,
Bapanaiah Penugonda,
Preview
|
PDF (277KB)
|
|
摘要:
This study was to determine the bond strength of composite to glass ionomer using the following adhesive resin cements: Imperva Dual, CB Metabond, All‐Bond, Geristore, and Panavia. All materials were mixed following the manufacturer's specifications. Bonded samples were thermocycled for 2000 xbetween 5°C and 55°C. Shear bond strengths were determined using an Instron Testing Machine. No statistical differences were noted between materials at the p<.05 level of significance. In addition, scanning electron micrographs were taken of the primed glass ionomer surfaces. These micrographs revealed varying amounts of matrix dissolution along with roughened surface topograph
ISSN:1496-4155
DOI:10.1111/j.1708-8240.1992.tb00711.x
出版商:Blackwell Publishing Ltd
年代:1992
数据来源: WILEY
|
10. |
New Technique for the Use of a Precision Attachment in the Fabrication of a Cast Crown/Core and Post Unit: Procedures and Case Report |
|
Journal of Esthetic and Restorative Dentistry,
Volume 4,
Issue 1,
1992,
Page 16-20
Sheldon Nadler,
Allan S. Deutsch,
Barry Lee Musikant,
Brettl. Cohen,
Preview
|
PDF (2182KB)
|
|
摘要:
A case report of a prefabricated cast post system, Flexi‐Cast, is presented. This tech‐nique provides maximium retention of the post in the root and crown to a core by incorporation of a prefabricated split‐shank threaded post with an attachment sleeve. Clinically this appears to be a simple predictable technique for the fabrication of a crown/core as a single
ISSN:1496-4155
DOI:10.1111/j.1708-8240.1992.tb00712.x
出版商:Blackwell Publishing Ltd
年代:1992
数据来源: WILEY
|