1. |
Editorial |
|
Clinical&Laboratory Haematology,
Volume 16,
Issue 1,
1994,
Page 1-1
Preview
|
PDF (49KB)
|
|
ISSN:0141-9854
DOI:10.1111/j.1365-2257.1994.tb00380.x
出版商:Blackwell Publishing Ltd
年代:1994
数据来源: WILEY
|
2. |
Osteonecrosis following treatment for Hodgkin's Disease |
|
Clinical&Laboratory Haematology,
Volume 16,
Issue 1,
1994,
Page 3-8
J. ELLIS,
U. MACLEOD,
D. SAMMON,
E. LINDSAY,
J.G. ERSKINE,
Preview
|
PDF (343KB)
|
|
摘要:
Summary.Osteonecrosis is usually considered to be a minor and rare late sequelae of treatment for Hodgkin's Disease (HD). However, over ten years six patients out of a total of 53 patients treated for HD at the haematology department of a district general hospital developed osteonecrosis, an incidence of 11.3%. Routine isotope bone scanning of patients produced two further asymptomatic cases. These results suggest a higher incidence than previously suspected of a problem which caused our patients considerable morbidity. Further measures are required to identify and adequately treat a significant cause of late morbidity following chemotherapy for HD.
ISSN:0141-9854
DOI:10.1111/j.1365-2257.1994.tb00381.x
出版商:Blackwell Publishing Ltd
年代:1994
数据来源: WILEY
|
3. |
Prognostic role of screening tests of haemostasis and underlying diseases in acute disseminated intra‐vascular coagulation in adults |
|
Clinical&Laboratory Haematology,
Volume 16,
Issue 1,
1994,
Page 9-13
H.P. PATI,
A.K. SARAYA,
V.D. CHARAN,
K.R. SUNDARAM,
M.C. SHARMA,
V.P. CHOUDHARY,
Preview
|
PDF (297KB)
|
|
摘要:
Summary.The significance of precipitating causes of acute disseminated intra‐vascular coagulation (DIC) and the severity of derangement of haemostasis based on laboratory investigations carried out initially were evaluated in 98 patients and was related to the fatal outcome in them. It was seen that septicaemia was the commonest precipating cause. Survival was better in patients in whom DIC was precipitated by obstetric causes compared with those with septicaemia (P2.5) as compared to their lower values (P1.5. It is concluded that deranged haemostasis and presence of septicaemia both independent of each other, contribute to the fatal outcome in acute DIC. Combination of both is associated with poorest prognosi
ISSN:0141-9854
DOI:10.1111/j.1365-2257.1994.tb00382.x
出版商:Blackwell Publishing Ltd
年代:1994
数据来源: WILEY
|
4. |
Direct carrier testing of haemophilia B by SSCP |
|
Clinical&Laboratory Haematology,
Volume 16,
Issue 1,
1994,
Page 15-20
P.A. MARTINEZ,
M.C. ROMEY,
J.F. SCHVED,
J.C. GRIS,
J. DEMAILLE,
M. CLAUSTRES,
Preview
|
PDF (371KB)
|
|
摘要:
Summary.Haemophilia B is due to multiple molecular defects in the factor IX gene. Most of them are single base substitutions, and can now be identified by direct sequencing of the coding sequence of the factor IX gene, preceded or not by a screening strategy. In some instances the mutation alters an enzyme recognition site and this allows rapid and accurate carrier testing and prenatal diagnosis in the affected pedigree. This was not the case for the previously described nt 31119 (G–>A) mutation that we found in an extended haemophilia B pedigree, during the search for mutations in the factor IX gene in patients from Southern France. We first detected this mutation by single stranded conformation polymorphism (SSCP) and then identified it by DNA sequencing. Carriership could be easily determined in the females of the pedigree by analysis of the SSCP patterns. Our results indicate that the SSCP analysis of amplified genomic DNA fragments can be successfully used as a diagnosis approach for direct carrier testing and prenatal diagnosi
ISSN:0141-9854
DOI:10.1111/j.1365-2257.1994.tb00383.x
出版商:Blackwell Publishing Ltd
年代:1994
数据来源: WILEY
|
5. |
Immunophenotyping of normal lymphocytes |
|
Clinical&Laboratory Haematology,
Volume 16,
Issue 1,
1994,
Page 21-32
ROWAYDA E. PETERS,
SAAD AL‐ISMAIL,
Preview
|
PDF (666KB)
|
|
摘要:
Summary.We report the data of direct and indirect immunofluorescence labelling of peripheral blood mononuclear cells obtained from 40 normal controls and nine patients having blood tests for non‐haematological disorders (PNHD controls) using flow cytometric analysis. Polyclonal and monoclonal antibodies were used to define the expression of cell surface antigen of T cells, their subsets, B cells, natural killer cells (NK) and myeloid cells. Normal values of absolute number and percentages of each of the populations of mononuclear cells were established and were sufficiently reproducible to be of clinical use. The percentages of positive values of T cells, T‐cell subsets, and B cells in ten normal controls when mononuclear cells were used, were comparable to those using whole blood lysis, APAAP immuno‐alkaline phosphatase, and E and M rosettes. The results obtained were similar in both the normal and PNHD controls. In most instances the percentage recovery of identified T, B and NK cells was complete. Currently we are using the results as reference values for lymphoid sub‐populations in normal c
ISSN:0141-9854
DOI:10.1111/j.1365-2257.1994.tb00384.x
出版商:Blackwell Publishing Ltd
年代:1994
数据来源: WILEY
|
6. |
Evaluation and use of the white blood cell differential provided by the Coulter® STKS in a children's hospital |
|
Clinical&Laboratory Haematology,
Volume 16,
Issue 1,
1994,
Page 33-42
M. FOURNIER,
C. ADENIS,
H. FONTAINE,
B. CARNAILLE,
J. GOUDEMAND,
Preview
|
PDF (545KB)
|
|
摘要:
Summary.The Coulter® STKS was evaluated in a children's hospital, in order to (a) compare theWBCdifferential given by the instrument to a 400 cell visual differential (reference method); (b) evaluate the sensitivity and specificity of the alarm system, and (c) provide data concerning the use and interpretation of results in children. 653 blood samples were collected. The Coulter® STKS results were studied in 523 patients having no morphological abnormalities in the blood smears, separated into subgroups according to the presence of STKS alarms and according to age. The results were found accurate both in STKS negative and STKS positive patients (i.e., those with alarms:‘Blasts', Imm Gran 2, Variant Lymph, NRBC, review slide). Negative STKS results had the same accuracy in all age groups, except in neonates where slide review must be systematically performed. The instrument exhibited a good sensitivity of the suspect flags studied (91.4%), with a lower specificity (72%) reflecting the number of false positive results found in our group, probably due to the cytological features particular to children. However, it was shown that the numerical results given by the Coulter® STKS in positive patients could be taken into account, provided that a scan of the blood smear was negative for morphological WBC abnormali
ISSN:0141-9854
DOI:10.1111/j.1365-2257.1994.tb00385.x
出版商:Blackwell Publishing Ltd
年代:1994
数据来源: WILEY
|
7. |
Assessment of neutrophil aggregation by Coulter® STKR and STKS haematological analysers |
|
Clinical&Laboratory Haematology,
Volume 16,
Issue 1,
1994,
Page 43-55
U. LIPPI,
P. BELLAVITE,
M. SCHINELLA,
M. NICOLI,
G. LIPPI,
Preview
|
PDF (766KB)
|
|
摘要:
Summary.We have studied an alternative method to aggregometry for the assessment of human polymorphonuclear (PMN) leucocyte aggregation. This simple, rapid and reliable procedure counts unaggregated cells on both Coulter’STKS and STKR haematological analysers by the impedance principle. Aggregation of PMN was induced by 15 min incubation with fresh autologous serum (FAS) after a 10 min phorbol myristate acetate (PMA) activation of neutrophils in small aliquots (0.25 ml) of suspension containing about 4.0 × 109PMN/l. Differences (x 100) between count of resting and PMA + FAS treated neutrophils/count of resting PMN reflect percent aggregation. By this procedure, PMN aggregation did not occur in autologous plasma from EDTA anticoagulated whole blood; it was partially inhibited by hydrocortisone, whereas inactivated or Zymosan activated sera gave values similar to those from FAS induced aggregation. PMA aggregation was dependent on Ca2++Mg2+concentration. Intra‐assay analytical variability did not exceed 4% on either instrument. Reference values (n= 20) of percent PMN aggregation were 50.7 ± 4.7 on STKS and 47.1 ± 4.8 on STKR. Most probably, the interindividual variance was due to the physiological variability of Mg2+and/or Ca2+concentrations in FAS. Thus, this procedure reflects the true PMN aggregability status in a given subject, and in a given electrolyte envir
ISSN:0141-9854
DOI:10.1111/j.1365-2257.1994.tb00386.x
出版商:Blackwell Publishing Ltd
年代:1994
数据来源: WILEY
|
8. |
Profiency testing in reticulocyte counting |
|
Clinical&Laboratory Haematology,
Volume 16,
Issue 1,
1994,
Page 57-64
REINHARD C. LOHMANN,
LINDA N. CRAWFORD,
DONALD E. WOOD,
Preview
|
PDF (419KB)
|
|
摘要:
Summary.The Laboratory Proficiency Testing Program tests and evaluates proficiency of clinical laboratories in Ontario, Canada. The programme began in 1974; testing of reticulocyte counts was added in 1982. From the beginning, the goal of the programme has been to ensure that the quality of practice in Ontario laboratories facilitates good quality patient care. Testing of indirect counting methods for reticulocytes is accomplished by the distribution of stained blood films. Performance is expressed in terms of accuracy and precision. Proficiency is assessed by comparing submitted results to an all‐methods’mean and result reliability by observing the coefficient of variation (CV) of the cohort. The quality of the results vary neither with the manual counting system used nor the type of laboratory. The CV commonly ranges from 25 to 30%, and this lack of accuracy appears to be inherent in the technology of manual reticulocyte counting. We conclude that manual reticulocyte counting is technologically obsolete but may be of clinical value if used in a qualitative fashion. It should probably be replaced by an automated met
ISSN:0141-9854
DOI:10.1111/j.1365-2257.1994.tb00387.x
出版商:Blackwell Publishing Ltd
年代:1994
数据来源: WILEY
|
9. |
A network‐based laboratory data processing system for use with the Coulter® STKS haematology analyser |
|
Clinical&Laboratory Haematology,
Volume 16,
Issue 1,
1994,
Page 65-74
ASHLEY J. ARNOTT,
PETER COPSON,
Preview
|
PDF (698KB)
|
|
摘要:
Summary.A highly automated laboratory data processing environment for use with Coulter STKS haematology analysers is described. This in‐house system is based on a network of personal computers running Novell Network software and communicating with an IBM® mainframe. The system captures the leucocyte scatterplot graphic and numeric parameters from the blood analysers, integrating this with patient demographic and request data held on the host computer. This composite picture is then reviewed on the network by laboratory personnel before generating printed reports. The system has provided greater data integrity, reduced paper flow and improved efficiency in the laboratory's operations and lays the foundations for dealing efectively with the next generation of advanced haematology analyse
ISSN:0141-9854
DOI:10.1111/j.1365-2257.1994.tb00388.x
出版商:Blackwell Publishing Ltd
年代:1994
数据来源: WILEY
|
10. |
Systemic hypertension—an unusual presentation of T‐cell lymphoma |
|
Clinical&Laboratory Haematology,
Volume 16,
Issue 1,
1994,
Page 75-78
IAN J. NEILLY,
N. BRUCE BENNETT,
AUDREY A. DAWSON,
DEREK J. KING,
GRAEME R.D. CATTO,
Preview
|
PDF (219KB)
|
|
ISSN:0141-9854
DOI:10.1111/j.1365-2257.1994.tb00389.x
出版商:Blackwell Publishing Ltd
年代:1994
数据来源: WILEY
|
|