|
1. |
Guest editorial |
|
Journal of High Resolution Chromatography,
Volume 3,
Issue 1,
1980,
Page 3-3
J. Calvin Giddings,
Preview
|
PDF (145KB)
|
|
ISSN:0935-6304
DOI:10.1002/jhrc.1240030102
出版商:Wiley Subscription Services, Inc., A Wiley Company
年代:1980
数据来源: WILEY
|
2. |
Polarity and selectivity in gas chromatography from the thermodynamic viewpoint. Part 1 |
|
Journal of High Resolution Chromatography,
Volume 3,
Issue 1,
1980,
Page 4-10
R. V. Golovnya,
T. A. Misharina,
Preview
|
PDF (664KB)
|
|
ISSN:0935-6304
DOI:10.1002/jhrc.1240030103
出版商:Wiley Subscription Services, Inc., A Wiley Company
年代:1980
数据来源: WILEY
|
3. |
Simple conversion of two standard gas chromatographs to all‐glass capillary systems |
|
Journal of High Resolution Chromatography,
Volume 3,
Issue 1,
1980,
Page 11-15
R. F. Severson,
R. F. Arrendale,
O. T. Chortyk,
Preview
|
PDF (303KB)
|
|
摘要:
AbstractTwo regular GC instruments were modified with injection port liners, split‐mode injection systems, pressure regulators, effluent traps and needle valves to produce an all‐glass GC‐2 system. This simple and inexpensive system allows the quantitative analyses of phenols, hydrocarbons, acids, sterols, terpenoids, and alkaloids with excellent reproducibility and linear response. Even more impressive was its ability to analyze a C45‐terpenoid alcohol, solanesol, as its TMS‐derivative (
ISSN:0935-6304
DOI:10.1002/jhrc.1240030104
出版商:Wiley Subscription Services, Inc., A Wiley Company
年代:1980
数据来源: WILEY
|
4. |
Direct measurement of mass fragmentograms for eluents from a micro‐liquid chromatograph using an improved nebulizing interface |
|
Journal of High Resolution Chromatography,
Volume 3,
Issue 1,
1980,
Page 16-20
Yu Yoshida,
Hiromasa Yoshida,
Shin Tsuge,
Tsugio Takeuchi,
Koichi Mochizuki,
Preview
|
PDF (324KB)
|
|
摘要:
AbstractAn improved vacuum nebulizing interface with a very short counter nozzle was developed for direct coupling of a micro‐LC and a quadrupole MS with CI‐chamber. With the LC‐MS system using the nebulizing interface, it became possible to take mass fragmentograms for various less volatile compounds such as glutamic acid, steroids, aromatic amines and chlorine‐containing insec
ISSN:0935-6304
DOI:10.1002/jhrc.1240030105
出版商:Wiley Subscription Services, Inc., A Wiley Company
年代:1980
数据来源: WILEY
|
5. |
Deactivation of glass capillary columns by dynamic vapour‐phase silylation |
|
Journal of High Resolution Chromatography,
Volume 3,
Issue 1,
1980,
Page 21-22
H. T. Badings,
J. G. Wassink,
Preview
|
PDF (168KB)
|
|
ISSN:0935-6304
DOI:10.1002/jhrc.1240030106
出版商:Wiley Subscription Services, Inc., A Wiley Company
年代:1980
数据来源: WILEY
|
6. |
A useful cement for gas chromatographers |
|
Journal of High Resolution Chromatography,
Volume 3,
Issue 1,
1980,
Page 23-24
Victor Pretorius,
Preview
|
PDF (157KB)
|
|
ISSN:0935-6304
DOI:10.1002/jhrc.1240030107
出版商:Wiley Subscription Services, Inc., A Wiley Company
年代:1980
数据来源: WILEY
|
7. |
Application of a multidimensional switching system (MDSS) to coal tar analysis |
|
Journal of High Resolution Chromatography,
Volume 3,
Issue 1,
1980,
Page 25-27
J. Ševčík,
Preview
|
PDF (151KB)
|
|
ISSN:0935-6304
DOI:10.1002/jhrc.1240030108
出版商:Wiley Subscription Services, Inc., A Wiley Company
年代:1980
数据来源: WILEY
|
8. |
Combination of two six‐port valves for chemical reaction analysis |
|
Journal of High Resolution Chromatography,
Volume 3,
Issue 1,
1980,
Page 28-28
Jorge Laine,
Preview
|
PDF (63KB)
|
|
ISSN:0935-6304
DOI:10.1002/jhrc.1240030109
出版商:Wiley Subscription Services, Inc., A Wiley Company
年代:1980
数据来源: WILEY
|
9. |
Prediction of TLC data for binary mobile phases by means of the RM‐values obtained for single solvents |
|
Journal of High Resolution Chromatography,
Volume 3,
Issue 1,
1980,
Page 29-30
J. K. Różyło,
I. Malinowska,
M. Jaroniec,
Preview
|
PDF (151KB)
|
|
ISSN:0935-6304
DOI:10.1002/jhrc.1240030110
出版商:Wiley Subscription Services, Inc., A Wiley Company
年代:1980
数据来源: WILEY
|
10. |
High performance liquid chromatographic resolution of the optical isomers of D,L‐tryptophane, D,L‐5‐hydroxytryptophan and D,L‐dopa on cellulose columns |
|
Journal of High Resolution Chromatography,
Volume 3,
Issue 1,
1980,
Page 31-32
G. Gübitz,
W. Jellenz,
D. Schönleber,
Preview
|
PDF (151KB)
|
|
摘要:
AbstractThe application of HPLC for the purpose of separation of some amino acid racemates with aromatic substituents is described.Using simple untreated cellulose with an average particle size of 7 μm as stationary phase, complete resolution of D,L‐tryptophane and D,L‐5‐hydroxytryptophane can be obtained. D,L‐3,4‐dihydroxyphenylalanine is resolved partially.The α‐value and resolution for D,L‐tryptophane was
ISSN:0935-6304
DOI:10.1002/jhrc.1240030111
出版商:Wiley Subscription Services, Inc., A Wiley Company
年代:1980
数据来源: WILEY
|
|