1. |
Editorial |
|
X‐Ray Spectrometry,
Volume 17,
Issue 1,
1988,
Page 1-1
John V. Gilfrich,
Preview
|
PDF (56KB)
|
|
ISSN:0049-8246
DOI:10.1002/xrs.1300170102
出版商:Wiley Subscription Services, Inc., A Wiley Company
年代:1988
数据来源: WILEY
|
2. |
Uncertainties in mass absorption coefficients in fundamental parameter X‐ray fluorescence analysis |
|
X‐Ray Spectrometry,
Volume 17,
Issue 1,
1988,
Page 3-12
B. A. R. Vrebos,
P. A. Pella,
Preview
|
PDF (1066KB)
|
|
摘要:
AbstractVarious compilations of mass absorption coefficients are currently used in fundamental parameter computer programs for correction of inter‐element effects in quantitative x‐ray fluorescence analysis. Statistically significant differences in results of analysis were observed for certain sample types when three commonly used compilations were compared, especially when only pure element standards were used for calibration. When type standards combined with a second degree polynomial fit to the standards are used for calibration. When type standards combined with a second degree polynomial fit to the standards are used for calibration, differences between compilations become negligible as determined from the analysis resu
ISSN:0049-8246
DOI:10.1002/xrs.1300170103
出版商:Wiley Subscription Services, Inc., A Wiley Company
年代:1988
数据来源: WILEY
|
3. |
Thick target X‐ray yields from proton bombardment |
|
X‐Ray Spectrometry,
Volume 17,
Issue 1,
1988,
Page 13-16
A. A. Katsanos,
A. Aravantinos,
N. Kallithrakas‐Kontos,
Preview
|
PDF (344KB)
|
|
摘要:
AbstractThe production yields for characteristic x‐rays from the bombardment of thick targets by protons are calculated by integrating the x‐ray production cross‐section for each element for the whole range of the protons, taking into account the self‐absorption of x‐rays. A simple approximation which can be applied with a pocket calculator is also presented, using simplified relationships for the energy dependence of the proton stopping power and the x‐ray production cross‐sections. The approximation allows very fast calculations, has an accuracy of better than 5% for low‐energy protons and is also very useful for the first steps in a computer program for PIXE analysis of thick targets, using the method of iterations. The calculated yields are compared with experimental results obtained on thick specimens of pure elements, compound
ISSN:0049-8246
DOI:10.1002/xrs.1300170104
出版商:Wiley Subscription Services, Inc., A Wiley Company
年代:1988
数据来源: WILEY
|
4. |
A flux for the fusion of samples in analysis by X‐ray fluorescence spectrometry |
|
X‐Ray Spectrometry,
Volume 17,
Issue 1,
1988,
Page 17-18
B. T. Eddy,
A. M. Balaes,
Preview
|
PDF (172KB)
|
|
摘要:
AbstractThe preparation of a pre‐fused flux for use in X‐ray fluorescence analysis is described. The flux is fused in graphite, quenched in water and then reduced to a fine powder in a polyurethane‐lined ball mill using tungsten carbide
ISSN:0049-8246
DOI:10.1002/xrs.1300170105
出版商:Wiley Subscription Services, Inc., A Wiley Company
年代:1988
数据来源: WILEY
|
5. |
Measurement of the dead time of XRF detection systems using a pulsed beam |
|
X‐Ray Spectrometry,
Volume 17,
Issue 1,
1988,
Page 19-21
L. Méray,
Preview
|
PDF (217KB)
|
|
摘要:
AbstractA method of measuring the dead time of nuclear detectors using a pulsed beam is described. The application of the method to detectors used in an electron microprobe device is reported and results obtained in this way are presented. The method seems to be suitable for measuring the dead time of any nuclear x‐ray counting system which can be operated with a pulsed bea
ISSN:0049-8246
DOI:10.1002/xrs.1300170106
出版商:Wiley Subscription Services, Inc., A Wiley Company
年代:1988
数据来源: WILEY
|
6. |
Yield calibration stability of a Si(Li) X‐ray detector system in a PIXE experimental setup over a period of 3 years in the 0.9–9.5 keV photon energy range |
|
X‐Ray Spectrometry,
Volume 17,
Issue 1,
1988,
Page 23-27
E. Bombelka,
F.‐W. Richter,
Preview
|
PDF (445KB)
|
|
摘要:
AbstractRelative experimental detector yields and yield ratios measured on mono‐ and bi‐element standard samples from 1984 to 1987 are presented. Above 3 keV photon energy the yields show good long‐term reproducibility. For example, the spread of 38 single yield measurements on the Au Lα x‐ray line is 1.5%. No temporary changes are observed. In contrast, the measured yields in the photon energy range from 3 keV down to 0.9 keV show distinct temporary changes. At the beginning and end of the measurement period the detector was routinely warmed and re‐pumped in order to ensure a good vacuum in the detector housing. At these times the yields show jumps, which increase with decreasing photon energy up to 20% for Na K x‐rays with 1.041 keV photon energy. Between the detector regenerations the yields show a decreasing tendency with time. This behaviour is attributed to the photon absorption in a varying ice layer on the liquid nitrogen‐cooled Si(Li) detector crystal. After the first regeneration the ice layer thickness was reduced by 0.7 μm. Between the regenerations the ice layer growth rate is estimated to be 0.004 μm per month corresponding to a 0.15 μm ice layer after 35 months. The second regeneration reduced the ice layer by
ISSN:0049-8246
DOI:10.1002/xrs.1300170107
出版商:Wiley Subscription Services, Inc., A Wiley Company
年代:1988
数据来源: WILEY
|
7. |
K‐shell fluorescence yields of some elements from nuclear decay parameters |
|
X‐Ray Spectrometry,
Volume 17,
Issue 1,
1988,
Page 29-31
N. P. S. Sidhu,
B. S. Grewal,
H. S. Sahota,
Preview
|
PDF (199KB)
|
|
摘要:
AbstractThe K‐shell fluorescence yields of nine elements with atomic numbers 33, 55, 59, 63, 66, 69, 71, 73 and 80 were measured from a knowledge of nuclear decay parameters. The results are in good agreement with earlier measurements and the fitted values of Bambyneket al.The merits and demerits of the method are discusse
ISSN:0049-8246
DOI:10.1002/xrs.1300170108
出版商:Wiley Subscription Services, Inc., A Wiley Company
年代:1988
数据来源: WILEY
|
8. |
Quantitative estimates of potassium in whole blood samples from diabetic |
|
X‐Ray Spectrometry,
Volume 17,
Issue 1,
1988,
Page 33-35
N. Venkateswara Rao,
S. Bhuloka Reddy,
D. G. S. Narayana,
G. Satyanarayana,
D. L. Sastry,
Preview
|
PDF (153KB)
|
|
摘要:
AbstractAn energy‐dispersive x‐ray spectrometer was used to make a quantitative estimate of potassium in whole blood samples from diabetic subjects and controls. A single standard method employing a fundamental parameter approach was followed for the quantification of potassium x‐ray intensities. The results show that the potassium levels in diabetics are about double those in con
ISSN:0049-8246
DOI:10.1002/xrs.1300170109
出版商:Wiley Subscription Services, Inc., A Wiley Company
年代:1988
数据来源: WILEY
|
9. |
11th International congress on X‐ray optics and microanalysis. Proceedings of a conference held in London, Ontario, Canada, 4–8 August 1986. Edited by J. D. Brown and R. H. Packwood 525 pages, printed in Canada by Graphic Services, University of Western Ontario |
|
X‐Ray Spectrometry,
Volume 17,
Issue 1,
1988,
Page 37-37
John Gilfrich,
Preview
|
PDF (123KB)
|
|
ISSN:0049-8246
DOI:10.1002/xrs.1300170110
出版商:Wiley Subscription Services, Inc., A Wiley Company
年代:1988
数据来源: WILEY
|
10. |
Announcements |
|
X‐Ray Spectrometry,
Volume 17,
Issue 1,
1988,
Page 38-38
Preview
|
PDF (100KB)
|
|
ISSN:0049-8246
DOI:10.1002/xrs.1300170112
出版商:Wiley Subscription Services, Inc., A Wiley Company
年代:1988
数据来源: WILEY
|
|