|
1. |
Tracking Instructional Updates |
|
Journal of Clinical Engineering,
Volume 25,
Issue 1,
2000,
Page 4-4
Preview
|
PDF (474KB)
|
|
ISSN:0363-8855
出版商:OVID
年代:2000
数据来源: OVID
|
2. |
FROM THE TECH'S BENCH |
|
Journal of Clinical Engineering,
Volume 25,
Issue 1,
2000,
Page 5-5
Nick,
Preview
|
PDF (473KB)
|
|
ISSN:0363-8855
出版商:OVID
年代:2000
数据来源: OVID
|
3. |
ACCREDITATION & CLINICAL ENGINEERING |
|
Journal of Clinical Engineering,
Volume 25,
Issue 1,
2000,
Page 6-7
Ode,
Preview
|
PDF (912KB)
|
|
ISSN:0363-8855
出版商:OVID
年代:2000
数据来源: OVID
|
4. |
WASHINGTON SCENE |
|
Journal of Clinical Engineering,
Volume 25,
Issue 1,
2000,
Page 8-9
Jay,
Preview
|
PDF (1045KB)
|
|
ISSN:0363-8855
出版商:OVID
年代:2000
数据来源: OVID
|
5. |
FOR YOUR INFORMATION |
|
Journal of Clinical Engineering,
Volume 25,
Issue 1,
2000,
Page 10-14
&NA;,
Preview
|
PDF (2941KB)
|
|
ISSN:0363-8855
出版商:OVID
年代:2000
数据来源: OVID
|
6. |
SOFTWARE & ELECTRONIC RESOURCES |
|
Journal of Clinical Engineering,
Volume 25,
Issue 1,
2000,
Page 15-16
Preview
|
PDF (1002KB)
|
|
ISSN:0363-8855
出版商:OVID
年代:2000
数据来源: OVID
|
7. |
GUEST COLUMNCollege of American Pathologists Revises Electrical Safety Testing Requirements |
|
Journal of Clinical Engineering,
Volume 25,
Issue 1,
2000,
Page 17-18
Thomas,
Preview
|
PDF (990KB)
|
|
ISSN:0363-8855
出版商:OVID
年代:2000
数据来源: OVID
|
8. |
TECHNOLOGY & TRENDS |
|
Journal of Clinical Engineering,
Volume 25,
Issue 1,
2000,
Page 19-25
&NA;,
Preview
|
PDF (3861KB)
|
|
ISSN:0363-8855
出版商:OVID
年代:2000
数据来源: OVID
|
9. |
PEER REVIEW PAPEREquipment Inclusion Criteria— A New Interpretation of JCAHO's Medical Equipment Management Standard |
|
Journal of Clinical Engineering,
Volume 25,
Issue 1,
2000,
Page 26-35
Binseng Wang,
Alan Levenson,
Preview
|
PDF (5656KB)
|
|
摘要:
&NA;To be accredited, every healthcare organization is required by JCAHO to determine which equipment should be included in its medical equipment management plan. Traditionally, most organizations have adopted the equipment inclusion criteria proposed by Fennigkoh and Smith (1989). This classic interpretation of JCAHO standard uses three criteria (equipment function, physical risks, and maintenance requirements) to establish a numerical value, called the equipment management (EM) number. Only equipment with an EM value higher than a predetermined threshold is included in the management plan. A fourth criterion (incident history) can be used to modify the EM number if data are available. If followed literally, this interpretation can lead to confusion and, occasionally, unreasonable conclusions that might result in inefficiencies and potentially unsafe conditions. A new interpretation of the inclusion criteria is proposed here. The major difference is in reinterpreting the equipment‐function criterion as the equipment's importance within the organization's global mission. This helps to balance risk to a single patient with the organization's commitment to its entire community. An additional factor that should be considered is the equipment utilization rate; heavily used items require more frequent inspection and higher priority for repairs. Together, these two elements form an interpretation that is more attuned to JCAHO's new directive (and general business management principles) and encourages greater concurrence with the organization's mission and vision.
ISSN:0363-8855
出版商:OVID
年代:2000
数据来源: OVID
|
10. |
PEER REVIEW PAPERModel for a Web‐Based Communication System Between Clinical Engineers And Medical Device Companies |
|
Journal of Clinical Engineering,
Volume 25,
Issue 1,
2000,
Page 36-49
Sandeep Misri,
William Hyman,
Preview
|
PDF (6207KB)
|
|
摘要:
&NA;Many medical device manufacturers have web sites where they provide useful, but not standardized information about their products and services. Similarly hospitals and clinics also have Web sites that can be accessed for information related to their services, and clinical engineers commonly have Web access. Because of the large numbers of manufacturers and clinical engineers, an effective means of interaction between the two is presently not available despite the availability of the Web. A missing link is a Web‐based system that could act as a central point of contact between clinical engineers and device manufacturers. This paper describes a model of such a communication system based on Internet technologies and relational databases. This system bridges the current communication gap and provides an effective and efficient means of information dissemination between device manufacturers and clinical engineers.
ISSN:0363-8855
出版商:OVID
年代:2000
数据来源: OVID
|
|