首页   按字顺浏览 期刊浏览 卷期浏览 Reliable Operation of a Proustite Parametric Oscillator
Reliable Operation of a Proustite Parametric Oscillator

 

作者: D. C. Hanna,   B. Luther‐Davies,   H. N. Rutt,   R. C. Smith,  

 

期刊: Applied Physics Letters  (AIP Available online 1972)
卷期: Volume 20, issue 1  

页码: 34-36

 

ISSN:0003-6951

 

年代: 1972

 

DOI:10.1063/1.1653969

 

出版商: AIP

 

数据来源: AIP

 

摘要:

An infrared parametric oscillator using proustite and pumped at 1.065 &mgr;m has been operated with peak output powers in the kilowatt range. No significant deterioration of output power was observed after several hours of running at 2 pps. Tuning from 1.82 to 2.56 &mgr;m was obtained, limited only by the reflectivity limits of the mirrors used. With careful design, DRO proustite oscillators covering the entire range 1.2–9.5 &mgr;m now appear feasible.

 