Cardiac Output of Men and Dogs Measured by in vivo Analysis of Iodinated (I131) Human Serum Albumin
作者:
Rex Huff,
David Feller,
Oliver Judd,
George Bogardus,
期刊:
Circulation Research
(OVID Available online 1955)
卷期:
Volume 3,
issue 6
页码: 564-569
ISSN:0009-7330
年代: 1955
出版商: OVID
数据来源: OVID
摘要:
A time-intensity analysis of I131was carried out with a highly shielded well-collimated scintillation detector placed over the chest of normal men and women, patients and dogs. I131human serum albumin solution was injected intravenously. The curves thus obtained when analyzed for cardiac output gave values not significantly different from simultaneously obtained direct Fick values.