首页   按字顺浏览 期刊浏览 卷期浏览 Electrophysiology and Metallosis: Support for an Oxidative (Free Radical) Mechanism in ...
Electrophysiology and Metallosis: Support for an Oxidative (Free Radical) Mechanism in the Human Eye

 

作者: Peter Good,   Keith Gross,  

 

期刊: Ophthalmologica  (Karger Available online 1988)
卷期: Volume 196, issue 4  

页码: 204-209

 

ISSN:0030-3755

 

年代: 1988

 

DOI:10.1159/000309902

 

出版商: S. Karger AG

 

关键词: Electroretinogram;Electro-oculogram;Siderosis;Metallosis;Retina;Retinal pigment epithelium;Siderosomes;Lipid peroxidation

 

数据来源: Karger

 

摘要:

Nine cases of metal intraocular foreign body are presented. This study investigates the use of electrodiagnostic techniques in the diagnosis of metallosis and as a prognostic indicator. The electro-oculogram (EOG) and the electroretinogram (ERG) indicate that there are two mechanisms of metallosis, one of which involves cytotoxic damage by siderosomes, and the other lipid peroxidation of photorecepter outer segments and retinal pigment epithelium. The evidence suggests that the location of the foreign body in the eye determines whether either or both of these mechanisms occur. We propose that these tests can help the ophthalmologist decide when a foreign body has to be removed and give information as to the mechanism of the pathological process.

 