首页   按字顺浏览 期刊浏览 卷期浏览 Non-Suppressed Conductivity Detection of Organic Acids in Plant Tissue Extracts by Ion-...
Non-Suppressed Conductivity Detection of Organic Acids in Plant Tissue Extracts by Ion-Exclusion Chromatography with Aromatic Acid Eluents

 

作者: ZuLiang Chen,   MarkA. Adams,  

 

期刊: Journal of Liquid Chromatography & Related Technologies  (Taylor Available online 1998)
卷期: Volume 21, issue 16  

页码: 2435-2445

 

ISSN:1082-6076

 

年代: 1998

 

DOI:10.1080/10826079808003589

 

出版商: Taylor & Francis Group

 

数据来源: Taylor

 

摘要:

Aromatic acids were evaluated as eluents for ion exclusion chromatography of organic acids with non-suppressed conductivity detection. The separation of organic acids, performed on an Aminex HPX-87H ion-exclusion column, using a variety of aromatic carboxylic acid eluents, is described in detail. Phthalic acid was found to be a suitable eluent for the separation of the organic acid tested, giving reasonable resolution and detection sensitivity. When 1 mM phthalic acid was used as eluent, an excellent separation of eight acids was achieved in 20 min. Calibration plots for the test acids were linear in the range 10−2M to 10−5M with detection limits of the order of 10−6M Compared to eluent containing sulfuric acid, the proposed method permits a more sensitive detection for the organic acids tested due to the lower background conductance of the eluent used. The proposed method was used for the determination of organic acids in plant tissue extracts with direct injection of sample extract.

 

点击下载:  PDF (429KB)