Rib Fracture Healing after Osteosynthesis with Wire Mesh Titanium and Screws: A Histological Study in Sheep
作者:
C.P.A.T. Klein,
H.B.M. van der Lubb,
R.H. Gahr,
期刊:
European Surgical Research
(Karger Available online 1989)
卷期:
Volume 21,
issue 6
页码: 347-354
ISSN:0014-312X
年代: 1989
DOI:10.1159/000129048
出版商: S. Karger AG
关键词: Rib fracture;Osteosynthesis;Titanium-implant
数据来源: Karger
摘要:
Twenty sheep were placed under general anesthesia and five ribs (6–10) were transected at their lateral angle using a pair of rib shears. The fractures were stabilized by titanium wire mesh plates. After 4, 6, 8, 10 and 12 weeks groups of 4 animals were sacrificed and rib samples were prepared for histological examinations. The study showed that the osteosynthesis stabilized the fractures and that the healing is similar to untreated rib fractures. This osteosynthesis method is a good contribution to severe injured chest treatmen
点击下载:
PDF
(962KB)
返 回