首页   按字顺浏览 期刊浏览 卷期浏览 Bicycle Ergometer For Paralyzed Muscle
Bicycle Ergometer For Paralyzed Muscle

 

作者: JERROLD,   PETROFSKY CHANDLER,   PHILLIPS HAREY,   HEATON ROGER,  

 

期刊: Journal of Clinical Engineering  (OVID Available online 1984)
卷期: Volume 9, issue 1  

页码: 13-20

 

ISSN:0363-8855

 

年代: 1984

 

出版商: OVID

 

关键词: Index Under: Exercise;Neuropathy;Ergometer;Isotonic Exercise;Dynamic Exercise;Rehabilitation;Bicycle Ergometer

 

数据来源: OVID

 

摘要:

A bicycle ergometer for exercising paralyzed muscle in man is described. This system can be used for isotonic training for both the cardiovascular system and skeletal muscle for individuals who are paralyzed. The device cannot be used on individuals who have lower motor neuron lesions. The device is based upon a standard MonarkTMbicycle ergometer. The ergometer has been modified with sensors for feedback of crank position that an Apple IITMcomputer then uses to coordinate stimulation of muscles. The muscles used in the study are theiliacusandquadriceps. Exercise training to test the device was conducted on four paraplegic and quadriplegic subjects over a period of 30 days. Exercise was induced three times per week for a period of 15 minutes. Results of these experiments show an increase in endurance and muscle size.

 