首页   按字顺浏览 期刊浏览 卷期浏览 Anomalous behaviour in certain versions of the critical oxygen index test
Anomalous behaviour in certain versions of the critical oxygen index test

 

作者: R. K. Wharton,  

 

期刊: Fire and Materials  (WILEY Available online 1981)
卷期: Volume 5, issue 1  

页码: 6-13

 

ISSN:0308-0501

 

年代: 1981

 

DOI:10.1002/fam.810050103

 

出版商: Heyden&Son Ltd.

 

数据来源: WILEY

 

摘要:

AbstractMeasured Critical Oxygen Index values at 40°C for Opal polymethylmethacrylate (Perspex) sheet have been found to be remarkably dependent on the gas velocity within the column of the Hot Flammability Test Apparatus. Investigation of the atmosphere present in the column has indicated that the effect is almost solely attributable to varying quantities of ambient air entering the column as the flow rate is altered. A modification to the apparatus is proposed that successfully prevents this entrainment of air at normal testing flow rates

 

点击下载:  PDF (836KB)