Tests on superconducting helix resonators
作者:
R. Benaroya,
A.H. Jaffey,
K. Johnson,
T. Khoe,
J.J. Livingood,
J.M. Nixon,
G.W. Parker,
W.J. Ramler,
J. Aron,
W.A. Wesolowski,
期刊:
Applied Physics Letters
(AIP Available online 1972)
卷期:
Volume 21,
issue 5
页码: 235-236
ISSN:0003-6951
年代: 1972
DOI:10.1063/1.1654359
出版商: AIP
数据来源: AIP
摘要:
A niobium helix‐resonator cavity close to the frequency suitable for a heavy‐ion accelerator has been subject to an 8‐week test, including 323 h at full power (axial electric fieldEax>2.5 MV/m). The cavity, with an anodically deposited protective film of Nb2O5, had a highQand supported high fields without deterioration over the whole period during which it was subject to a moderate internally generated x‐ray dose. Properties were found to be stable against considerable thermal cycling and exposure to air. Measurement of emitted x‐ray maximum energy allowed an independent corroboration of the field measurement calibration.