Tetracycline inequivalence: the importance of 96-hour testing
作者:
CHARLES DAVIS,
JULES VANDERSARL,
ERIC KRAUS,
期刊:
The American Journal of the Medical Sciences
(OVID Available online 1973)
卷期:
Volume 265,
issue 1
页码: 69-74
ISSN:0002-9629
年代: 1973
出版商: OVID
关键词: Antibiotics;Generic equivalence;Bioavailability;Tetracycline
数据来源: OVID
摘要:
Present regimens for determining the bioavailability of tetracycline antibiotics may be inadequate. When blood and urine levels of tetracycline HCI were monitored throughout a 96-hour treatment period, film-coated tetracycline tablets used in this study were found to be inferior to tetracycline capsules. This important difference would have been missed if the usual six-hour single-dose observations had been performed.