Modified Open Renal Biopsy
作者:
Barre F. Finan,
Thomas E. Brewer,
Ronald D. Hughes,
James A. Wellons,
期刊:
American Journal of Nephrology
(Karger Available online 1989)
卷期:
Volume 9,
issue 4
页码: 300-302
ISSN:0250-8095
年代: 1989
DOI:10.1159/000167984
出版商: S. Karger AG
关键词: Open renal biopsy;Percutaneous needle biopsy;Bronchial-biopsy forceps
数据来源: Karger
摘要:
Fifty consecutive patients underwent a modified open renal biopsy using bronchial forceps under general anesthesia. A small incision (2–3 cm) was made, and several small pieces of renal tissue (5–7) were excised in each case. Adequate tissue for diagnosis was obtained in 100% of the biopsies. Morbidity was minimal, and no deaths occurred as a result of biopsy. Traditionally, the open renal biopsy consists of a large incision (7–10 cm) with a deep wedge excision. It is significant that the modified technique provided a high tissue yield (the average number of glomeruli was 80) with few complications. This tissue yield was significantly higher than that usually seen with percutaneous needle b