Pure and cesiated cw volume source performance at the Culham Ion Source Test Stand
作者:
R. McAdams,
R. F. King,
G. Proudfoot,
A. J. T. Holmes,
期刊:
AIP Conference Proceedings
(AIP Available online 1992)
卷期:
Volume 287,
issue 1
页码: 353-367
ISSN:0094-243X
年代: 1992
DOI:10.1063/1.44797
出版商: AIP
数据来源: AIP
摘要:
A review is given of progress in ion source performance at the cw test stand. Data is presented both for pure and cesiated source performance. For uncesiated operation we show how the performance depends on cathode area by changing both filament number and diameter. We have proved that this is due to the collection of ions from the plasma by the cathode structure. Through the use of cesium in the ion source the H−and D−current is enhanced by about a factor of two. An accelerator perveance limit was identified which prevented all the current available from the source being transported, but this was overcome by a new accelerator design allowing very high currents, 86 mA of H−and 37.3 mA of D−, to be extracted from a 16 mm diameter aperture.
点击下载:
PDF
(807KB)
返 回