首页   按字顺浏览 期刊浏览 卷期浏览 Pure and cesiated cw volume source performance at the Culham Ion Source Test Stand
Pure and cesiated cw volume source performance at the Culham Ion Source Test Stand

 

作者: R. McAdams,   R. F. King,   G. Proudfoot,   A. J. T. Holmes,  

 

期刊: AIP Conference Proceedings  (AIP Available online 1992)
卷期: Volume 287, issue 1  

页码: 353-367

 

ISSN:0094-243X

 

年代: 1992

 

DOI:10.1063/1.44797

 

出版商: AIP

 

数据来源: AIP

 

摘要:

A review is given of progress in ion source performance at the cw test stand. Data is presented both for pure and cesiated source performance. For uncesiated operation we show how the performance depends on cathode area by changing both filament number and diameter. We have proved that this is due to the collection of ions from the plasma by the cathode structure. Through the use of cesium in the ion source the H−and D−current is enhanced by about a factor of two. An accelerator perveance limit was identified which prevented all the current available from the source being transported, but this was overcome by a new accelerator design allowing very high currents, 86 mA of H−and 37.3 mA of D−, to be extracted from a 16 mm diameter aperture.

 

点击下载:  PDF (807KB)



返 回