首页   按字顺浏览 期刊浏览 卷期浏览 A New Method for Direct Detection of Heparin on Surface-Modified Intraocular Lenses
A New Method for Direct Detection of Heparin on Surface-Modified Intraocular Lenses

 

作者: Burkhard Dick,   Karl-Georg Schmidt,   Dieter Eisenmann,   Norbert Pfeiffer,  

 

期刊: Ophthalmologica  (Karger Available online 1997)
卷期: Volume 211, issue 2  

页码: 75-78

 

ISSN:0030-3755

 

年代: 1997

 

DOI:10.1159/000310762

 

出版商: S. Karger AG

 

关键词: Cataract surgery;Intraocular lens;Heparin surface modification;Quality control

 

数据来源: Karger

 

摘要:

Background: Examination of surface-bound heparin on synthetic polymers can only be performed by few staining methods. These methods are limited by an only approximate detection of heparin visible at high magnification. Other methods only measure heparin quantitatively (per square dimension) and are rather sensitive to artifacts. Due to its homogeneous staining pattern, the modified toluidine blue staining technique, using a non-protein-based substance, allows examination and analysis of the homogeneity of the monomolecular heparin layer even under critical conditions like scanning electron microscopy. Materials and Methods: For critical examination of the heparin layer, this method was used for 5 sterile heparin surface-modified (HSM) monofocal (Pharmacia, 809C, 5 mm optical zone), 2 multifocal PMMA (Pharmacia, 81 IE, 6 mm optical zone) and 1 standard PMMA intraocular lenses (IOLs; Pharmacia, 809P, 5 mm optical zone). A special mixture containing a sodium borate buffer was used to avoid cross-reactions of toluidine with phenylimines, which permit a covalent surface linkage of heparin to synthetic polymeric materials via reductive amination. This resulted in less coarse-grained complex agglutination. After light and spectral microscopy of the surface of stained IOLs, scanning electron microscopy was performed to investigate the reliability and validity of this modified staining method. Results: All HSM IOLs showed a homogeneous heparin structure and coating, which could be demonstrated even under critical photographic circumstances. Conclusions: The modification of the original toluidine blue staining method introduced by Jaques in 1943 is a reliable and reproducible technique for the detailed in vitro analysis of surface-bound heparin with a low artifact rate. Because of the detailed detection of heparin on polymeric surfaces, this staining method is recommended for special problems, e.g. in cataract surgery.

 

点击下载:  PDF (1721KB)



返 回