首页   按字顺浏览 期刊浏览 卷期浏览 Comparison of Coincidence Counting and Focusing Collimators with Various Isotopes in Br...
Comparison of Coincidence Counting and Focusing Collimators with Various Isotopes in Brain Tumour Detection

 

作者:

 

期刊: The British Journal of Radiology  (WILEY Available online 1964)
卷期: Volume 37, issue 439  

页码: 531-543

 

年代: 1964

 

DOI:10.1259/0007-1285-37-439-531

 

出版商: The British Institute of Radiology

 

数据来源: WILEY

 

摘要:

Coincidence counting and focusing collimators with different isotopes are compared for detection of brain tumours with external scanning. A modification of Dewey and Sinclair's (1961) figure of merit for the best compromise between resolution and sensitivity for detection of the tumour is measured experimentally using spherical glass bulbs in a tank of water, to represent tumours in the head. The probabilities of detecting tumours of different sizes are calculated for different isotopes making certain assumptions. It is concluded that74As or72As with focusing collimators are better than the other isotopes investigated for detection of brain tumours.125I is not suitable.

 

点击下载:  PDF (1076KB)