首页   按字顺浏览 期刊浏览 卷期浏览 Use of a Special Device for the Treatment of Overf iltration after Glaucoma Filtering S...
Use of a Special Device for the Treatment of Overf iltration after Glaucoma Filtering Surgery

 

作者: G. Cennamo,   N. Rosa,   M.A. Breve,  

 

期刊: Ophthalmologica  (Karger Available online 1997)
卷期: Volume 211, issue 2  

页码: 61-65

 

ISSN:0030-3755

 

年代: 1997

 

DOI:10.1159/000310759

 

出版商: S. Karger AG

 

关键词: Glaucoma filtering surgery;Echography;Immersion scleral shells;Flat anterior chamber

 

数据来源: Karger

 

摘要:

Background: Standardized A and B scan echography were used to look for the possible presence of ciliochoroidal detachment in patients with flat anterior chamber following glaucoma filtering surgery. For this purpose, a scleral shell filled with saline solution was inserted between the lids. As a deepening of the anterior chamber was found in some patients, we planned to utilize these devices for the treatment of flat anterior chambers after glaucoma filtering surgery. Methods: 16 patients with flat anterior chambers after glaucoma filtering surgery underwent the insertion of a scleral shell filled with saline solution between the lids. The shell was left in place for 15 min. Results: In all of our patients a deepening of the anterior chamber was achieved. In 5 patients 1 application, in 6 patients 2 applications, in 4 patients 3 applications were needed. Conclusions: The advantages of using this procedures are: the procedure is quick; it does not disturb the corneal epithelium; it is cheap; it does not require suturing the conjunctiva; it can be part of the examination of the anterior segment with echography to look for any ciliary body detachment.

 

点击下载:  PDF (1712KB)



返 回