首页   按字顺浏览 期刊浏览 卷期浏览 Rotational and gas temperatures in a surface conversion negative ion source
Rotational and gas temperatures in a surface conversion negative ion source

 

作者: M. J. de Graaf,   Z. Qing,   G. van Rooij,   M. C. M. van de Sanden,   D. C. Schram,   R. M. A. Heeren,   A. W. Kleyn,  

 

期刊: AIP Conference Proceedings  (AIP Available online 1992)
卷期: Volume 287, issue 1  

页码: 588-594

 

ISSN:0094-243X

 

年代: 1992

 

DOI:10.1063/1.44770

 

出版商: AIP

 

数据来源: AIP

 

摘要:

The Fulcher band emission spectrum is used to determine rotational temperatures in the FOMSCE plasma setup. The measured temperatures are found to vary from 500 to 700 K, whereas usually in this kind of plasmas they are very close to room temperature. In this paper the interpretation of the spectra will be discussed. The influence of some plasma settings on the measured temperature will be presented.

 