The Relationship of Mean Defect to Corrected Loss Variance in Glaucoma and Ocular Hypertension
作者:
Andrew Pearson,
Larry B. Baldwin,
Thomas J. Smith,
期刊:
Ophthalmologica
(Karger Available online 1990)
卷期:
Volume 200,
issue 1
页码: 16-21
ISSN:0030-3755
年代: 1990
DOI:10.1159/000310072
出版商: S. Karger AG
关键词: Automated perimetry;Glaucoma;Ocular hypertension;Visual field
数据来源: Karger
摘要:
Statistical analysis of visual-field data is permitted by the quantitative techniques used in automated perimetry. The visual-field indices mean defect (MD) and corrected loss variance (CLV) provide an opportunity to analyze and follow visual fields mathematically. We investigated the relationship of MD to CLV in 32 glaucoma suspects and 17 patients with visual-field defects due to chronic open-angle glaucoma. In glaucoma patients with early and moderate disease (up to a MD of 18 dB), the CLV statistically covaried with the MD (R2 = 0.85). Beyond an MD of 18 dB, increases in the MD seemed to cause a decline in the CLV. These results differ from prior reports on the relationship of MD and CLV. Reasons for this and implications for the use of these statistics in the clinical management of the glaucoma patient are discussed. These results may be helpful in the understanding of the pathophysiologic basis of damage in glaucoma.