11. |
In vivoquantitation of lesion radioactivity using external counting methods |
|
Memoirs and Proceedings of the Chemical Society,
Volume 3,
Issue 4,
1998,
Page 253-255
Stephen R. Thomas,
Harry R. Maxon,
James G. Kereiakes,
Preview
|
PDF (243KB)
|
|
摘要:
Quantitative external counting methods for thein vivodetermination of the activity uniformly distributed in an area of interest (lesion) have been developed. The theoretical work has been extended to include the effects of regions of differing attenuation coefficient and of non‐target organ activity in the tissue surrounding the lesion. A clinical quantitative procedure utilizing a “calibrated” gamma camera and associated computer system is described. Studies including a bone substitute material in a water phantom confirmed the basic theoretical work.
ISSN:0269-3127
DOI:10.1118/1.594287
出版商:American Association of Physicists in Medicine
年代:1998
数据来源: WILEY
|
12. |
Calculations of two‐dimensional electric field and potential distributions around electrodes in conducting media |
|
Memoirs and Proceedings of the Chemical Society,
Volume 3,
Issue 4,
1998,
Page 256-258
Richard L. Hutson,
Preview
|
PDF (239KB)
|
|
摘要:
Tumor cells can be killed by heating to 42.5°C. It is convenient to localize heating by passing electric current at 500 kHz through tissue between a pair of electrodes. It is desirable to determine, for a given electrode–tissue configuration, what the resulting field and, therefore, current distribution will be. A computer program FFEARS was used to calculate electric field and potential distributions in two dimensions for three simple cases.
ISSN:0269-3127
DOI:10.1118/1.594235
出版商:American Association of Physicists in Medicine
年代:1998
数据来源: WILEY
|
13. |
Real‐time display of radiation field intensity distribution |
|
Memoirs and Proceedings of the Chemical Society,
Volume 3,
Issue 4,
1998,
Page 259-263
Peter A. Berardo,
James A. Willis,
Preview
|
PDF (365KB)
|
|
摘要:
A real‐time display system has been designed and tested for use with a radiation field monitor. The system uses only pulse and waveform generators, a multiplexer, and an oscilloscope. The display consists of either a three‐dimensional representation of the field intensity distribution or a series of simultaneous profiles.
ISSN:0269-3127
DOI:10.1118/1.594236
出版商:American Association of Physicists in Medicine
年代:1998
数据来源: WILEY
|
14. |
Comments on cost effectiveness of radiation detector materials for γ‐ray camera applications |
|
Memoirs and Proceedings of the Chemical Society,
Volume 3,
Issue 4,
1998,
Page 264-264
Louis Lavoie,
Preview
|
PDF (131KB)
|
|
ISSN:0269-3127
DOI:10.1118/1.594237
出版商:American Association of Physicists in Medicine
年代:1998
数据来源: WILEY
|
15. |
Table of Contents |
|
Memoirs and Proceedings of the Chemical Society,
Volume 3,
Issue 4,
1998,
Page -
Preview
|
PDF (39KB)
|
|
ISSN:0269-3127
DOI:10.1002/j.2473-4209.1976.tb36072.x
出版商:Wiley
年代:1998
数据来源: WILEY
|