21. |
Characteristics of electron beams from a new 25‐MeV linear accelerator |
|
Memoirs and Proceedings of the Chemical Society,
Volume 12,
Issue 6,
1998,
Page 799-805
P. O'Brien,
H. B. Michaels,
J. E. Aldrich,
J. W. Andrew,
Preview
|
PDF (492KB)
|
|
摘要:
Clinically useful electron fields are produced on the Atomic Energy of Canada, Limited Therac 25 linear accelerator by computer‐controlled scanning of the electron beam. Measurements were made to determine the properties of these electron fields. Central axis percentage depth dose and bremsstrahlung background were compared for these fields and for the fields from selected machines that use scattering foils. Dose calibrations were made in both water and polystyrene using the American Association of Physicists in Medicine Task Group 21 protocol. Measurements were made to determine the relative output factors, virtual source position, and the attenuation of the electron fields by lead.
ISSN:0269-3127
DOI:10.1118/1.595788
出版商:American Association of Physicists in Medicine
年代:1998
数据来源: WILEY
|
22. |
Neutron sources in a 24‐MV medical linear accelerator |
|
Memoirs and Proceedings of the Chemical Society,
Volume 12,
Issue 6,
1998,
Page 806-809
Philip D. LaRiviere,
Preview
|
PDF (287KB)
|
|
摘要:
During the assembly of the prototype Clinac 2500, a unique opportunity arose to measure the cumulative total neutron yield of the machine as the major subassemblies were added, section by section. Differentiation of the results led to an inventory of the relative strength of the several neutron sources identified. The method utilized the fact that the scattered neutron fluence in a cavity in concrete is nearly uniform throughout the space and proportional to the fast neutron source strength. When normalized to the neutron output of the guide with bend magnet vacuum chamber, the relative neutron source strengths found were target, 1.9; primary collimator, 2.4; steel filter, 0.6; tungsten filter, 1.5; and jaw system, 0.8 open and approximately 2.0 closed. There is reasonable agreement between these measurements and published estimates of the yields from the major components of the treatment head.
ISSN:0269-3127
DOI:10.1118/1.595743
出版商:American Association of Physicists in Medicine
年代:1998
数据来源: WILEY
|
23. |
Erratum: A new radiation dosimeter using a pyroelectric detector [Med. Phys.11, 866 (1984)] |
|
Memoirs and Proceedings of the Chemical Society,
Volume 12,
Issue 6,
1998,
Page 809-809
M. H. de Paula,
A. A. Carvalho,
S. Mascarenhas,
R. L. Zimmerman,
Preview
|
PDF (39KB)
|
|
ISSN:0269-3127
DOI:10.1118/1.595744
出版商:American Association of Physicists in Medicine
年代:1998
数据来源: WILEY
|
24. |
Comments on “A new radiation dosimeter using a pyroelectric detector” |
|
Memoirs and Proceedings of the Chemical Society,
Volume 12,
Issue 6,
1998,
Page 810-810
M. H. de Paula,
A. A. Carvalho,
S. Mascarenhas,
R. L. Zimmerman,
Preview
|
PDF (68KB)
|
|
ISSN:0269-3127
DOI:10.1118/1.595745
出版商:American Association of Physicists in Medicine
年代:1998
数据来源: WILEY
|
25. |
A Handbook of Physics for Radiologists and Radiographersedited by D. Gifford |
|
Memoirs and Proceedings of the Chemical Society,
Volume 12,
Issue 6,
1998,
Page 811-812
Steven J. Goetsch,
Preview
|
PDF (238KB)
|
|
ISSN:0269-3127
DOI:10.1118/1.595747
出版商:American Association of Physicists in Medicine
年代:1998
数据来源: WILEY
|
26. |
Recent Developments in Digital Imaging[Medical Physics Monograph No. 12] edited by K. Doi, L. Lanzl, and P.‐J. P. Lin |
|
Memoirs and Proceedings of the Chemical Society,
Volume 12,
Issue 6,
1998,
Page 812-813
Bruce Hasegawa,
Preview
|
PDF (252KB)
|
|
ISSN:0269-3127
DOI:10.1118/1.595789
出版商:American Association of Physicists in Medicine
年代:1998
数据来源: WILEY
|
27. |
Radiation Dosimetry: Electron Beams with Energies Between 1 and 50 MeV(ICRU Report No. 35) |
|
Memoirs and Proceedings of the Chemical Society,
Volume 12,
Issue 6,
1998,
Page 813-813
Geoffrey S. Ibbott,
Preview
|
PDF (124KB)
|
|
ISSN:0269-3127
DOI:10.1118/1.595780
出版商:American Association of Physicists in Medicine
年代:1998
数据来源: WILEY
|
28. |
The Health Physics and Radiological Health Handbookedited by B. Shleien and M. S. Terpilak |
|
Memoirs and Proceedings of the Chemical Society,
Volume 12,
Issue 6,
1998,
Page 814-814
Milton E. McLain,
Preview
|
PDF (129KB)
|
|
ISSN:0269-3127
DOI:10.1118/1.595754
出版商:American Association of Physicists in Medicine
年代:1998
数据来源: WILEY
|
29. |
Books Received |
|
Memoirs and Proceedings of the Chemical Society,
Volume 12,
Issue 6,
1998,
Page 815-815
Preview
|
PDF (101KB)
|
|
ISSN:0269-3127
DOI:10.1002/j.2473-4209.1985.tb36230.x
出版商:Wiley
年代:1998
数据来源: WILEY
|
30. |
Table of Contents |
|
Memoirs and Proceedings of the Chemical Society,
Volume 12,
Issue 6,
1998,
Page -
Preview
|
PDF (143KB)
|
|
ISSN:0269-3127
DOI:10.1002/j.2473-4209.1985.tb36231.x
出版商:Wiley
年代:1998
数据来源: WILEY
|